Refine
Year of publication
Document Type
- Article (33)
- Conference Proceeding (22)
- Part of a Book (2)
- Book (1)
- Doctoral Thesis (1)
Keywords
- API 1130 (1)
- CPM (1)
- Deutschland / Technische Regeln für brennbare Flüssigkeiten (1)
- Elektrodenvorbereitung (1)
- Fehlererkennung (1)
- Fehlerortung (1)
- Implantat (1)
- Kernspintomografie (1)
- Kohlenstoff (1)
- Leak detection (1)
- Leckerkennung (1)
- Leckortung (1)
- Lecksuchgerät (1)
- Lecküberwachung (1)
- Nanofaser (1)
- PEM fuel cells (1)
- PEM-Brennstoffzelle (1)
- Polymer-Elektrolytmembran-Brennstoffzelle (1)
- Regeln der Technik (1)
- Sauerstoffplasmaaktivierung (1)
- Spondylodese (1)
- TRFL (1)
- carbon nano fibres (1)
- electrode preparation (1)
- leak locating (1)
- leak monitoring (1)
- oxygen plasma activation (1)
Institute
- Elektrotechnik und angewandte Naturwissenschaften (59) (remove)
Stereotactic frame systems are widely used in neurosurgery. The accuracy of frame devices is considered as a gold standard to which the accuracy of new frameless stereotactic navigation systems is compared. The purpose of this study is to develop a general approach for the prediction of the application accuracy of stereotactic systems. The approach will be applied to the frame‐based biopsy performed with three frame devices: Leksell G, Cosman–Roberts–Wells (CRW), and Brown–Roberts–Wells (BRW). A work‐flow analysis will be carried out demonstrating that the accuracy relevant for a clinical application comprises several error sources including imaging, target and entry point selection, image to frame coordinates registration, and the setting of mechanical parameters of the frame. These error sources will be postulated to obey a Gaussian distribution probability density. The linear, i.e., Gaussian, error propagation, will be used to link all error contributions thus to calculate the cumulative accuracy of the frame used in the application. Although the Gaussian approach is an approximation, it allows for an analytical treatment of the accuracy. Both the accuracy at the target point and the accuracy of the probe needle guidance along the planned trajectory have been investigated. Of great significance is the relationship found between accuracy, pixel dimension, and image slice thickness, the latter being the dominant factor for slices of more than 1.5 mm thickness, yielding inaccuracies larger than 1.5 mm. For target points the predictions for the application accuracy have been compared to the results of measurements, showing good agreement with the experimental data.
A qualitative work‐flow analysis of a neurosurgical procedure indicates that the resolution of the image used to plan the intervention is the major source of inaccuracy. Quantitative experimental measurements confirm this observation. They fail, however, to explain the relationship between the accuracy of the frame components involved in a stereotactic procedure and the overall application accuracy. This investigation shows that the novel Gaussian approach is a flexible framework for the calculation of the application accuracy of frame systems. Therefore, the Gaussian approach provides a detailed understanding of the interplay between the various factors affecting accuracy. The basic ideas and limitations of the Gaussian approach are briefly explained. The effect of fiducial marker distribution and registration is investigated and shown to introduce a spatial dependence to the accuracy. The results of the Gaussian approach are compared with experimental data for three stereotactic frame devices: Leksell G, Cosman–Roberts–Wells, and Brown–Roberts–Wells. Although the Gaussian approach is an approximation, it reproduces the accuracy measured in the experiment within the statistical error of that experiment. Comp Aid Surg 4:77–86 (1999). © 1999 Wiley‐Liss, Inc.
Three-dimensional magnetic resonance medical images may contain scanner- and patient-induced geometric distortion. For qualitative diagnosis, geometric errors of a few millimeters are often tolerated. However, quantitative applications such as image-guided neurosurgery and radiotherapy can require an accuracy of a millimeter or better. We have developed a method to accurately measure scanner-induced geometric distortion and to correct the MR images for this type of distortion. The method involves a number of steps. First, a specially designed phantom is scanned that contains a large number of reference structures on positions with a manufacturing error of less than 0.05 mm. Next, the positions of the reference structures are automatically detected in the scanned images and a higher-order polynomial distortion-correction transformation is estimated. Then the patient is scanned and the transformation is applied to correct the patient images for the detected distortion. The distortion-correction method is explained in detail in this paper. The accuracy of the method has been measured with synthetically generated phantom scans that contain an exactly-known amount and type of distortion. The reproducibility of the method has been measured by applying it to a series of consecutive phantom scans. Validation results are briefly described in this paper, a more-detailed description is given in another submission to SPIE Medical Imaging 2001.
Many fluids transported by pipelines are in some sense hazardous. It is therefore often necessary to install leak detection (and locating) systems (LDS), especially due to legal regulations like the "Code for Federal Regulations (CFR) Title 49 Part 195", API 1130 2nd Ed., both for the USA, or the "Technische Regeln für Fernleitungen" (TRFL) (Technical Rules for Pipelines) in Germany. This paper gives a survey of methodologies, methods and techniques for leak detection and locating. The survey starts with some remarks concerning (legal) regulations both for the USA and for Germany. Some few words about externally based systems (due to API 1130 2nd Ed.) follow next. A significant part of the paper deals with internally based systems (also due to API 1130 2nd Ed.) like balancing systems (line balance, volume balance, compensated mass balance etc.), Real Time Transient Model LDS (RTTM-LDS), pressure/flow monitoring and statistical analysis LDS. Different methods for leak locating (gradient intersection method, wave propagation analysis etc.) will also be shown. The presentation of an Extended RTTM approach (E-RTTM) combining advantages of conventional RTTM LDS and statistical analysis follows next, together with the demonstration of applicability by means of two examples, a liquid multi-batch pipeline, and a gas pipeline. Sketching future work and the conclusion conclude the survey.