In this paper, the effect of computed tomography (CT) values of metals in 12-bit and 16-bit extended Hounsfield Unit (EHU) scale on dose calculations in radiotherapy treatment planning systems (TPS) were quantified. Dose simulations for metals in water environment were performed with the software PRIMO in 6MV photon mode. The depth dose profiles were analysed and the relative dose differences between the metals determined with 12-bit and 16-bit CT imaging, respectively, were calculated. Maximum dose differences of ΔAl= 3.0%, ΔTi= 4.5%, ΔCr= 6.2% and ΔCu= 11.6% were measured. In order to increase the accuracy of dose calculation on patients with implants, CT imaging in the EHU scale is recommended.
We report on the suitability of two different ranges of Hounsfield units (HU) in computed tomography (CT) for the quantification of metallic components of active implantable medical devices (AIMD). The conventional Hounsfield units (CHU) range, which is traditionally used in radiology, is well suited for tissue but suspected inappropriate for metallic materials. Precise HU values are notably beneficial in radiotherapy (RT) for accurate dose calculations, thus for the safety of patient carrying implants. Some of today’s CT machines offers an extended Hounsfield units (EHU) range. This study presents CT acquisitions of a water phantom containing various metallic discs and an implantable-cardioverter defibrillator (IPG). We show that the comparison of HU values at EHU and CHU ranges clearly reveals the superiority and accuracy of EHU. Some geometrical discrepancies perpendicular to slices are observed. At EHU metal artifact reduction algorithms (MAR) underestimates HU values rendering MAR potentially inappropriate for RT.
We report on investigations that illustrate the interaction between the specific immune system and a young avascular tumor growing due to a diffusive nutrient supply. We formulate a hybrid cellular automata-partial differential equation (CA-PDE) model which includes cell cycle dynamics and allows for tracking the spatial and temporal evolution of this elaborate biological system. We present results of two dimensional numerical simulations that, specifically in this work, include special cases of the spherical and papillary tumor growth, the infiltration of immune system cells into the tumor and the escape of tumor cells from the regime of the immune cells.
Many fluids transported by pipelines are in some sense hazardous. It is therefore often necessary to install leak detection (and locating) systems (LDS), especially due to legal regulations like the "Code for Federal Regulations (CFR) Title 49 Part 195", API 1130 2nd Ed., both for the USA, or the "Technische Regeln für Fernleitungen" (TRFL) (Technical Rules for Pipelines) in Germany. This paper gives a survey of methodologies, methods and techniques for leak detection and locating. The survey starts with some remarks concerning (legal) regulations both for the USA and for Germany. Some few words about externally based systems (due to API 1130 2nd Ed.) follow next. A significant part of the paper deals with internally based systems (also due to API 1130 2nd Ed.) like balancing systems (line balance, volume balance, compensated mass balance etc.), Real Time Transient Model LDS (RTTM-LDS), pressure/flow monitoring and statistical analysis LDS. Different methods for leak locating (gradient intersection method, wave propagation analysis etc.) will also be shown. The presentation of an Extended RTTM approach (E-RTTM) combining advantages of conventional RTTM LDS and statistical analysis follows next, together with the demonstration of applicability by means of two examples, a liquid multi-batch pipeline, and a gas pipeline. Sketching future work and the conclusion conclude the survey.
Nanofluids, defined as fluids containing suspended solid nanoparticles, are potential systems for utilization in biomedical applications. Magnetic Particle Imaging (MPI) uses superparamagnetic nanofluids, e.g. a colloidal suspension of iron oxide particles. In this work a new biocompatible nanofluid based on pure and stable ferromagnetic carbon is investigated. Although this material has a relatively small value of coercive magnetic field, it does exhibit a true ferromagnetic behavior up to 300 K. We present results obtained from numerical investigations performed to calculate the impact of a ferromagnetic magnetization to the MPI signal chain. Moreover, by modeling ferromagnetic magnetization we prove here the general suitability of ferromagnetic materials for MPI. Due to the low saturation magnetization, however, MPI for ferromagnetic carbon will be possible only in the near future when realistic concentrations of the nanofluid ferromagnetic carbon will be experimentally obtainable.
Cancer is a leading cause of morbidity and mortality worldwide, with approximately 14 million new cases and 8.2 million cancer related deaths in 2012 [1]. Moreover, the global cancer burden is expected to exceed 20 million new cancer cases by 2025. Understanding the spatial and temporal behaviour of cancer is a crucial precondition to achieve a successful treatment. Because no two cancer cases are the same, every patient should receive a treatment plan designed specifically for her case, in order to improve the patient’s survival chances.
A simplified model for spondylodesis, ie fixation of vertebrae by osteosynthesis, is developed for virtual magnetic resonance imaging (MRI) examinations to numerically calculate energy absorption. This paper presents results of calculated energy absorption in body tissue surrounding titanium rod implants. In general each wire or rod behaves like an antenna in electromagnetic fields. The specific absorption rate (SAR) profile describes dependence of implant size. SAR hotspots appear near the rod edges. Depending of the size of implant fixation SAR is 62%(small fixation) up to 90.95%(large fixation) higher than without implants. In addition, local SAR profile displays local dependency on tissue: SAR is lower between the vertebrae.
Metallic implants in magnetic resonance imaging (MRI) are a potential safety risk since the energy absorption may increase temperature of the surrounding tissue. The temperature rise is highly dependent on implant size. Numerical examinations can be used to calculate the energy absorption in terms of the specific absorption rate (SAR) induced by MRI on orthopaedic implants. This research presents the impact of titanium osteosynthesis spine implants, called spondylodesis, deduced by numerical examinations of energy absorption in simplified spondylodesis models placed in 1.5 T and 3.0 T MRI body coils. The implants are modelled along with a spine model consisting of vertebrae and disci intervertebrales thus extending previous investigations [1], [2]. Increased SAR values are observed at the ends of long implants, while at the center SAR is significantly lower. Sufficiently short implants show increased SAR along the complete length of the implant. A careful data analysis reveals that the particular anatomy, i.e. vertebrae and disci intervertebrales, has a significant effect on SAR. On top of SAR profile due to the implant length, considerable SAR variations at small scale are observed, e.g. SAR values at vertebra are higher than at disc positions.
Metallic implants in magnetic resonance imaging (MRI) are a potential safety risk since the energy absorption may increase temperature of the surrounding tissue. The temperature rise is highly dependent on implant size. Numerical examinations can be used to calculate the energy absorption in terms of the specific absorption rate (SAR) induced by MRI on orthopaedic implants. This research presents the impact of titanium osteosynthesis spine implants, called spondylodesis, deduced by numerical examinations of energy absorption in simplified spondylodesis models placed in 1.5 T and 3.0 T MRI body coils. The implants are modelled along with a spine model consisting of vertebrae and disci intervertebrales thus extending previous investigations [1, 2]. Increased SARvalues are observed at the ends of long implants, while at the center SAR is significantly lower. Sufficiently short implants show increased SAR along the complete length of the implant. A careful data analysis reveals that the particular anatomy, i.e. vertebrae and disci intervertebrales, has a significant effect on SAR. On top of SAR profile due to the implant length, considerable SAR variations at small scale are observed, e.g. SAR values at vertebra are higher than at disc positions.