Filtern
Erscheinungsjahr
Dokumenttyp
- Konferenzveröffentlichung (35) (entfernen)
Volltext vorhanden
- nein (35) (entfernen)
Schlagworte
- AEM-Electrolysis (1)
- Air handling unit (1)
- Building Information Modeling (1)
- Climate change (1)
- Current Pulses (1)
- Electrodeposition (1)
- Energieeffizienz (1)
- Flat-Channel (1)
- Future capacity needs (1)
- Hydraulic compression, Carbon Nano Fibers, PEM Fuel Cells, Catalyst utilization (1)
- Hygiene (1)
- Klimatechnik (1)
- Klimawandel (1)
- Klimaänderung (1)
- Launcher (1)
- Leistungsreserve (1)
- Ni-Mo alloy Catalyst (1)
- PEM Electrolysis, Hydrogen, Hydraulic Compression, High Pressure (1)
- PEM fuel cells; electrode preparation; carbon nanofibers; in-situ performance test (1)
- RLT-Geräte (1)
- Raumluftströmung (1)
- Sinusoidal (1)
- Skalierung (1)
- Thermal Stress (1)
- Urban heat island (1)
- Wärmepumpen, VDI 4645, Jahresarbeitszahl, Wärmewende, Bewertungstool (1)
- Ähnlichkeitstheorie (1)
Institut
- Westfälisches Energieinstitut (35) (entfernen)
Aufgrund der Energiewende und den steigenden Anforderungen an die technische Gebäudeausrüstung gewinnt der Betrieb von Wärmepumpen in Gebäuden immer mehr an Bedeutung. Inzwischen existiert eine Vielzahl an Wärmepumpen-Systemen, die unterschiedliche Vor- und Nachteile sowie Einsatzmöglichkeiten aufweisen. Sofern die Installation einer Wärmepumpe für den Wohngebäudesektor in Betracht gezogen wird, muss eruiert werden, welches System sowohl ökologisch als auch ökonomisch für das Bauvorhaben am sinnvollsten ist. Hierfür wurde eine Bewertungstool entwickelt, das den Einsatz der unterschiedlichen Wärmepumpensysteme bewertet und auch Nutzern mit wenig Expertise eine Entscheidungshilfe ermöglicht. Für eine möglichst ganzheitliche Betrachtung können verschiedene Szenarien mit Hilfe des Bewertungstools überprüft werden. Hierzu können Indikatoren wie Standortdaten, Gebäudedaten, Parameter für die Trinkwassererwärmung, die Systemtemperaturen der Heizung und die Betriebsweise der Wärmepumpe im Tool variiert werden. Die Ergebnisse des Bewertungstools zeigen, wie die unterschiedlichen Nutzungsanforderungen sich auf die Jahresarbeitszahl und den Energiebedarf auswirken. Zusätzlich werden Investitions- und Verbrauchskosten für die unterschiedlichen Szenarien abgeschätzt und berechnet. Bei der ökologischen Bewertung wird der Fokus der Betrachtung auf den TEWI-Wert gelegt, um den Einfluss von verschiedener Kältemittel im Lebenszyklus der Wärmepumpe zu berücksichtigen.
Air Handling units (AHU) are designed to guarantee a high indoor air quality for any time and outdoor condition all over the year. To do so, the AHU removes particle matter like dust or pollen and adapts the thermophysical properties of air to the desired, seasonal indoor comfort conditions. AHU have a robust design and thus operate for more than fifteen years, sometimes even for decades. An AHU designed today must consider and anticipate the change of user needs as well as outdoor air conditions for the next twenty years. To anticipate the outdoor air condition of coming decades, scientific models exist, which allow the design of peak performance and capacities of the air treatment components. It is most likely, that the ongoing climate change will lead to higher temperatures as well as higher humidity, while the comfort zone of human beings will remain at today’s values. Next to the impact of global warming with average rise of mean air temperature local effects will influence the operation of AHU. On effect investigated here is the steep temperature increase in city centres called urban heat islands. Heating and cooling capacities as well as water consumption for humidification are investigated for a reference AHU for fifteen regional locations in Germany. These regions represent all climate zones within the country. Additionally, the urban heat island effect was investigated for Berlin Alexanderplatz compared a rural area close by. The AHU was chosen to operate in an intensive care unit of a hospital. The set-up leads to 24/7 operation with 8760 hours per year. The article presents the modelling of current and future weather data as well as the unit set up. The calculated hourly performance and capacity parameters for current (reference year 2012) and future weather data (reference year 2045) yield energy consumption and peak loads of the unit for heating, cooling and humidification. The results are displayed by relative comparisons of each performance value.
Various aqueous citrate electrolyte compositions for the Ni-Mo electrodeposition are explored in order to deposit Ni-Mo alloys with Mo-content ranging from 40 wt% to 65 wt% to find an alloy composition with superior catalytic activity towards the hydrogen evolution reaction (HER). The depositions were performed on copper substrates mounted onto a rotating disc electrode (RDE) and were investigated via scanning electron microscopy (SEM), X-ray fluorescence (XRF) and X-ray diffraction (XRD) methods as well as linear sweep voltammetry (LSV) and impedance spectroscopy. Kinetic parameters were calculated via Tafel analysis. Partial deposition current densities and current efficiencies were determined by correlating XRF measurements with gravimetric results. The variation of the electrolyte composition and deposition parameters enabled the deposition of alloys with Mo-content over the range of 40-65 wt%. An increase in Mo-content in deposited alloys was recorded with an increase in rotation speed of the RDE. Current efficiency of the deposition was in the magnitude of <1%, which is characteristic for the deposition of alloys with high Mo-content. The calculated kinetic parameters were used to determine the Mo-content with the highest catalytic activity for use in the HER.
Alle Maßnahmen der Technischen Gebäudeausrüstung sollten daran gemessen werden, den Primär-energieverbrauch so gering wie möglich zu halten, dabei aber auch die geforderten Raumzustände während der Gebäude- und Anlagennutzung sicherzustellen.
Heute geplante Gebäude und deren RLT-Anlagen werden mit großer Wahrscheinlichkeit auch noch in 15 bis 20 Jahren in Betrieb sein, so dass lokale Klimaänderungen heute bereits mitgedacht und –geplant werden sollten. Die Testreferenzjahre des Deutschen Wetterdienstes bieten diese Möglichkeit mit lokalen Wetterdaten für die Bezugsjahre 2015 und 2045.
Am Beispiel eines Zentralluftgerätes einer Krankenhaus-Intensivstation wurde für die 15 Wetter¬stationen der VDI 4710, Blatt 3 in Deutschland untersucht, wie sich die Leistungsanforderungen von heute zum Jahr 2045 hin ändern werden und welche Konsequenzen sich daraus für die Planung ableiten lassen. Hierbei werden die Leistungen, Energieverbräuche und Betriebszeiten der einzelnen RLT-Komponenten analysiert und verglichen.
Darüber hinaus wurde erstmalig ein „Deutschlandwetter“ auf Basis der Regionen berechnet. Dieser Ansatz liefert die stündlichen Witterungsverhältnisse für das Bundesgebiet. Wenn diese Methode auf die tatsächlichen Wetterdaten der zurückliegenden Jahre angewandt wird, kann damit analog zum Wind- und Solarindex ein Heiz- bzw. Kühlindex beschrieben werden. Damit lassen sich Modellierungsansätze zur Beschreibung der Energiewende im Gebäudesektor deutlich verbessern.
Menschen verbringen einen großen Teil ihrer Zeit in Innenräumen. Um dafür die notwendige thermische Behaglichkeit zu gewährleisten, müssen schon bei der Nutzungsplanung die Temperaturen und Luftbewegungen im Raum vorhergesagt werden können. Bei anderen Anwendungen wiederum sind diese Größen relevant für die Prozesssicherheit (z. B. Labore, Operationssaal). Die Vorhersagen erfolgen zum Beispiel durch Strömungssimulationen oder an sogenannten Mock Up Räumen, die eine 1:1 Nachbildung des relevanten Raums darstellen. Bei größeren Räumen wie z. B. Konzertsälen steigt der Aufwand erheblich an.
Eine auf den ersten Blick vergleichsweise einfache Lösung ergibt sich durch Untersuchungen an skalierten Modellräumen. Allerdings ist hier die Ähnlichkeit zwischen Modell und Realausführung bei nicht-isothermen Strömungen nicht gegeben. Die dimensionslosen Kenngrößen Reynolds Zahl Re und Archimedes Zahl Ar sind nicht identisch, da sie mit unterschiedlichen Exponenten bei der charakteristischen Länge skalieren, so dass sie durch die Wahl eines anderen Mediums oder Anpassung der Temperaturen nicht hinreichend kompensiert werden können.
Im Labor für Klimatechnik an der Westfälischen Hochschule sollen mit Hilfe von experimentellen Modelluntersuchungen und dem Vergleich mit der Realausführung Erkenntnisse gewonnen werden, in wie weit ein Kompromiss aus Ähnlichkeit und Genauigkeit gefunden werden kann, um technisch relevante Fragestellungen am Modell zu beantworten.
Die Leitfragen dabei sind:
- Wie lassen sich Modellergebnisse auf reale Raumluftströmungen übertragen?
- Unter welchen Bedingungen ist die Ähnlichkeit zwischen Modell und Realausführung noch gegeben?
- Wie sehen Leitlinien für die praktische Anwendung der Ähnlichkeitsgesetze aus?
Ein Büroraum mit unterschiedlichen Luftführungsvarianten und thermischen Lasten stellt dabei die Realausführung dar. Das Modell ist im Maßstab 1:5 herunterskaliert.