Filtern
Erscheinungsjahr
Dokumenttyp
Schlagworte
- Building Information Modeling (5)
- Kühllastberechnung (4)
- Klimaänderung (3)
- Polymer-Elektrolytmembran-Brennstoffzelle (3)
- Qualitätsplan (3)
- Reinraumtechnik (3)
- VDI 2078 (3)
- Deutschlandwetter (2)
- Electrodeposition (2)
- Industry Foundation Classes (2)
- Klimatechnik (2)
- Klimawandel (2)
- hydraulic compression (2)
- modular stack design (2)
- water electrolysis (2)
- carbon nanofibers, platinum electrodeposition, ele ctrochemical surface area (1)
- AEM-Electrolysis (1)
- Aerosol (1)
- Air handling unit (1)
- Anodenkatalysator (1)
- Arbeit, Kapital und Staat (1)
- Augmented (1)
- Augmented Electromagnetic Accelerators (1)
- Augmented Multiphase (1)
- Augmented Multiphase Rail Launcher (1)
- Augmented Three-Phase AC-Railgun (1)
- BIM (1)
- BIM Weiterbildung (1)
- Brennstoffzellen (1)
- Catalysis (1)
- Climate change (1)
- Current Pulses (1)
- Datenmanagement (1)
- Electrolysis (1)
- Electromagnetic Launcher (1)
- Elektrokatalysator (1)
- Elektrolyseur (1)
- Elektrolyseure (1)
- Energieeffizienz (1)
- Energieversorgungsunternehmen (1)
- Energy Storage Mode (1)
- Erneuerbare Energien (1)
- Evolutorische (1)
- Flat-Channel (1)
- Future capacity needs (1)
- Gas Diffusion Electrode (1)
- Graphitisierung (1)
- Haustechnik (1)
- Homogene Kühlung (1)
- Hydraulic cell compression (1)
- Hydraulic compression, Carbon Nano Fibers, PEM Fuel Cells, Catalyst utilization (1)
- Hydrogen evolution reaction (1)
- Hygiene (1)
- IFC (1)
- Kohlenstoff-Nanoröhre (1)
- Kohlevlies (1)
- Laser Synthesis Electrocatalytic Water Splitting (1)
- Laser sintern (1)
- Launcher (1)
- Lehre (1)
- Leistungsreserve (1)
- Linear Electromagnetic Accelerator (1)
- Lüftungsanlage (1)
- Magnetic Pressure (1)
- Membran-Elektroden-Einheit (1)
- Membrane (1)
- Modular Augmented Launcher (1)
- Modular Design (1)
- Multiphase Rail Launcher (1)
- Mund-Nasen-Schutz (1)
- Muzzle Velocity (1)
- Nachhaltigkeit, GEG, intelligente Gebäude (1)
- Ni-Mo alloy Catalyst (1)
- ORR OER (1)
- PEM Electrolysis, Hydrogen, Hydraulic Compression, High Pressure (1)
- PEM electrolysis (1)
- PEM fuel cell (1)
- PEM fuel cell electrocatalysts, Carbon nanofibers, Oxygen plasma activation, Pulsed electroplating. (1)
- PEM fuel cells; electrode preparation; carbon nanofibers; in-situ performance test (1)
- PEM water electrolysis (1)
- PEM-Elektrolyse (1)
- PEM-Elektrolysezellen (1)
- PEMWE (1)
- Plädoyer (1)
- Porous Transport Layers (1)
- Praxis (1)
- PtCoMn (1)
- RLT-Auslegung (1)
- RLT-Geräte (1)
- RLT-Geräte, Klimawandel, Leistungsreserve (1)
- Rail Launcher (1)
- Railgun (1)
- Raumluft (1)
- Raumluftreiniger (1)
- Raumluftströmung (1)
- Raumlufttechnisches Gerät (1)
- SARS-CoV-2 (1)
- Semi-Infinite Plate (1)
- Sinusoidal (1)
- Skalierung (1)
- Stack <Brennstoffzelle> (1)
- Strategiesches Management (1)
- TGA-Büro (1)
- Technische Gebäudeausrüstung (1)
- Ternary alloy catalyst preparation (1)
- Testsystem (1)
- Thermal Performance (1)
- Thermal Stress (1)
- Titansubstrat (1)
- Upscaling laboratory models (1)
- Urban heat island (1)
- Wasserstoff-Kraftwerke (1)
- Wasserstoffenergietechnik (1)
- Wärmepumpen, VDI 4645, Jahresarbeitszahl, Wärmewende, Bewertungstool (1)
- aerosol (1)
- air hygiene (1)
- airborne infection (1)
- bipolar plate (1)
- carbon nanofibers, platinum electrodeposition, electrocatalysts (1)
- coatings (1)
- corrosion resistance (1)
- face mask (1)
- hydraulic cell compression (1)
- infrared heating panel (1)
- mobile Luftreiniger (1)
- novel (1)
- polymer electrolyte membrane (1)
- ventilation (1)
- Ähnlichkeitstheorie (1)
Institut
- Westfälisches Energieinstitut (106) (entfernen)
Menschen verbringen einen großen Teil ihrer Zeit in Innenräumen. Um dafür die notwendige thermische Behaglichkeit zu gewährleisten, müssen schon bei der Nutzungsplanung die Temperaturen und Luftbewegungen im Raum vorhergesagt werden können. Bei anderen Anwendungen wiederum sind diese Größen relevant für die Prozesssicherheit (z. B. Labore, Operationssaal). Die Vorhersagen erfolgen zum Beispiel durch Strömungssimulationen oder an sogenannten Mock Up Räumen, die eine 1:1 Nachbildung des relevanten Raums darstellen. Bei größeren Räumen wie z. B. Konzertsälen steigt der Aufwand erheblich an.
Eine auf den ersten Blick vergleichsweise einfache Lösung ergibt sich durch Untersuchungen an skalierten Modellräumen. Allerdings ist hier die Ähnlichkeit zwischen Modell und Realausführung bei nicht-isothermen Strömungen nicht gegeben. Die dimensionslosen Kenngrößen Reynolds Zahl Re und Archimedes Zahl Ar sind nicht identisch, da sie mit unterschiedlichen Exponenten bei der charakteristischen Länge skalieren, so dass sie durch die Wahl eines anderen Mediums oder Anpassung der Temperaturen nicht hinreichend kompensiert werden können.
Im Labor für Klimatechnik an der Westfälischen Hochschule sollen mit Hilfe von experimentellen Modelluntersuchungen und dem Vergleich mit der Realausführung Erkenntnisse gewonnen werden, in wie weit ein Kompromiss aus Ähnlichkeit und Genauigkeit gefunden werden kann, um technisch relevante Fragestellungen am Modell zu beantworten.
Die Leitfragen dabei sind:
- Wie lassen sich Modellergebnisse auf reale Raumluftströmungen übertragen?
- Unter welchen Bedingungen ist die Ähnlichkeit zwischen Modell und Realausführung noch gegeben?
- Wie sehen Leitlinien für die praktische Anwendung der Ähnlichkeitsgesetze aus?
Ein Büroraum mit unterschiedlichen Luftführungsvarianten und thermischen Lasten stellt dabei die Realausführung dar. Das Modell ist im Maßstab 1:5 herunterskaliert.
A compact and efficient PEM electrolyser stack design based on hydraulic single cell compression
(2019)
For this study gas diffusion electrodes (GDE) with low platinum loading are prepared for the application as anode in polymer electrolyte membrane fuel cell (PEMFC) systems based on hydraulic compression. As catalyst support material, carbon nanofibers (CNF) are investigated because of their high specific surface area and high graphitization degree. The electrode preparation is optimized by an economic and environmental friendly pre-treatment process in oxygen plasma. For GDE manufacture an ink containing oxygen plasma activated CNFs as well as hydrophilic polymer is used. After spray coating of this CNF ink on a graphitic substrate, platinum is deposited using the pulse plating technique. Preliminary results showed a considerable improvement of CNF dispersibility as well as an increased amount and an optimized morphology of the deposited platinum. Morphology and microstructure are observed by scanning electron microscopy as well as transmission electron microscopy. Platinum loading is determined by thermogravimetric analysis to be in the range of 0.01 mg cm-2 to 0.017 mg cm-2. Furthermore, MEAs are prepared from these GDEs and testing is performed in a novel modular fuel cell test stack based on hydraulic compression. Technical information about stack design and functions is given in this work.
Membrane electrode assemblies (MEA) developed at the Westphalian Energy Institute for polymer electrolyte membrane fuel cells (PEMFC) are high tech systems containing various materials structured in nanoscale, at which electrochemical reactions occur on catalyst nano particle surfaces. For low reactance homogeneous compression of the MEA’s layers is necessary. A novel stack architecture for electrochemical cells, especially PEMFC as well as PEM electrolysers, has been developed according to achieve ideal cell operation conditions. Single cells of such a stack are inserted into flexible slots that are surrounded by hydraulic media. While operation the hydraulic media is pressurised which leads to an even compression and cooling of the stack’s cells. With this stack design it has been possible to construct a test facility for simultaneous characterisation of several MEA samples. As compression and temperature conditions of every single sample are equal, with the novel test system the effect of e.g. different electrode configurations can be investigated. Furthermore, the modular stack design leads to the development of hybrid energy applications combining fuel cells, electrolysers, batteries as well as metal hydride tanks in one system.
In this work, a novel polymer electrolyte membrane water electrolyzer (PEMWE) test cell based on hydraulic single-cell compression is described. In this test cell, the current density distribution is almost homogeneous over the active cell area due to hydraulic cell clamping. As the hydraulic medium entirely surrounds the active cell components, it is also used to control cell temperature resulting in even temperature distribution. The PEMWE single-cell test system based on hydraulic compression offers a 25 cm2 active surface area (5.0 × 5.0 cm) and can be operated up to 80°C and 6.0 A/cm2. Construction details and material selection for the designed test cell are given in this document. Furthermore, findings related to pressure distribution analyzed by utilizing a pressure-sensitive foil, the cell performance indicated by polarization curves, and the reproducibility of results are described. Experimental data indicate the applicability of the presented testing device for relevant PEMWE component testing and material analysis.
In this experimental work we present a novel electrolyzer system for the production of hydrogen and oxygen at high pressure levels without an additional mechanical compressor. Due to its control strategies, the operation conditions for this electrolyzer can be kept optimal for each load situation of the system. Furthermore, the novel system design allows for dynamic long-term operation as well as for easy maintainability. Therefore, the device meets the requirements for prospective power-to-gas applications, especially, in order to store excess energy from renewable sources. A laboratory scale device has been developed and high-pressure operation was validated. We also studied the long-term stability of the system by applying dynamic load cycles with load changes every 30 sec. After 80 h of operation the used membrane electrode assembly (MEA) was investigated by means of SEM, EDX and XRD analysis.
An Augmented Multiphase Rail Launcher With a Modular Design: Extended Setup and Muzzle Fed Operation
(2024)
Die Neuberechnung der Kühllast von Gebäuden im Bestand wird immer dann nötig, wenn sich größere Nutzungsänderungen ergeben. Dabei ist die Datenlagen zur Bausubstanz und dem Aufbau der Umschließungsflächen meist unzureichend für die Eingabe in die Berechnungsalgorithmen nach VDI 2078:2015-06. Der Artikel analysiert an einem denkmalgeschützten Verwaltungsgebäude die wichtigsten Einflussfaktoren auf die Kühllast. Dabei wir auch ein Vergleich zur lange gültigen Vorgängerrichtline von 1996 durchgeführt.
Besondere Herausforderung: Weiterbildung. BIM: Einbinden von kleinen und mittelgroßen TGA-Büros
(2019)
Die Digitale Transformation im Bauwesen heißt Building Information Modeling, kurz BIM. Damit die zahlreichen kleinen und mittelständischen Ingenieur- und Planungsbüros hier mithalten können, müssen passende Weiterbildungs- und Einführungskonzepte für BIM geschaffen werden. Der Artikel untersucht die Herausforderungen und Hemmnisse dafür in Deutschland.
Aufgrund der Energiewende und den steigenden Anforderungen an die technische Gebäudeausrüstung gewinnt der Betrieb von Wärmepumpen in Gebäuden immer mehr an Bedeutung. Inzwischen existiert eine Vielzahl an Wärmepumpen-Systemen, die unterschiedliche Vor- und Nachteile sowie Einsatzmöglichkeiten aufweisen. Sofern die Installation einer Wärmepumpe für den Wohngebäudesektor in Betracht gezogen wird, muss eruiert werden, welches System sowohl ökologisch als auch ökonomisch für das Bauvorhaben am sinnvollsten ist. Hierfür wurde eine Bewertungstool entwickelt, das den Einsatz der unterschiedlichen Wärmepumpensysteme bewertet und auch Nutzern mit wenig Expertise eine Entscheidungshilfe ermöglicht. Für eine möglichst ganzheitliche Betrachtung können verschiedene Szenarien mit Hilfe des Bewertungstools überprüft werden. Hierzu können Indikatoren wie Standortdaten, Gebäudedaten, Parameter für die Trinkwassererwärmung, die Systemtemperaturen der Heizung und die Betriebsweise der Wärmepumpe im Tool variiert werden. Die Ergebnisse des Bewertungstools zeigen, wie die unterschiedlichen Nutzungsanforderungen sich auf die Jahresarbeitszahl und den Energiebedarf auswirken. Zusätzlich werden Investitions- und Verbrauchskosten für die unterschiedlichen Szenarien abgeschätzt und berechnet. Bei der ökologischen Bewertung wird der Fokus der Betrachtung auf den TEWI-Wert gelegt, um den Einfluss von verschiedener Kältemittel im Lebenszyklus der Wärmepumpe zu berücksichtigen.
BIM in Lehre und Praxis
(2019)
BIM-Daten sind vielfältig und entstehen an unterschiedlichen Zeitpunkten im Bauprojekt. Das Verständnis und der Umgang mit diesen Daten sind wesentliche Merkmale der BIM-Methodik.
Für den Anwender ist dabei nicht immer sofort klar, wie und in welcher Detailtiefe Bauwerksinformationen – über die reine Geometrie hinaus – bereitgestellt werden müssen.
In diesem Buch werden die Modelle und Formate vor-
gestellt. Dabei werden insbesondere die Attribute und Eigenschaften der BIM-Objekte betrachtet.
Die Nutzung der Daten und das dazugehörige Datenmanagement werden anschaulich erklärt. Praktische Tipps zur richtigen Softwareauswahl schließen das Buch ab.
Building Information Modeling, kurz BIM, wird als revolutionäre Methode gepriesen, die der Baubranche helfen soll, effizienter und kostengünstiger zu bauen. Gerne wird hierbei der Vergleich mit der Einführung von CAD-Systemen in den 1990er Jahren herangezogen, der jedoch zu kurz greift. BIM ist vielmehr als der Wechsel vom Tuschestift hin zur Computermaus. Dieser Beitrag gibt einen kurzen Einblick in das Thema BIM und den heutigen Stand in Deutschland. Hierbei soll insbesondere die Sicht der Bauherren und Betreiber berücksichtigt werden, da diese in den meisten Betrachtungen nur oberflächlich gesteift werden.
Um CO2-frei, mit erneuerbaren Technologien, Energie umzuwandeln, zu speichern und Wasserstoff zu produzieren, bedarf es einer Technologie, welche zu hoher Leistungsdichte, Flexibilität und Effizienz fähig ist. Die Polymerelektrolytmembran-(PEM) Wasser-Elektrolyse besitzt das Potential alle diese Attribute in sich zu vereinen, weswegen sie eine Schlüsseltechnologie bei dem Umstieg auf erneuerbare Energien darstellt. Die aktuellen hohen Beladungen der Elektroden mit Katalysatormaterial für die Sauerstoffentwicklungsreaktion (OER) wie Iridium und die bisher noch ungenügend erforschten Alterungsmechanismen dieser über eine längere Nutzdauer, sind bisher die größten Herausforderungen für die großflächige industrielle Nutzung dieser Systeme. Mit diesem Hintergrund stellt sich diese Arbeit der Herausforderung die untersuchten PEM-Anoden mit reduzierter Beladung, hinsichtlich ihrer Stabilität und Alterungsmechanismen zu charakterisieren und den ersten Schritt in Richtung eines Degradationsprotokolls zu machen, um solche Elektroden künftig zu untersuchen. In der vorgegangenen Arbeit, aus welcher die hier untersuchten Proben stammen, wurden Elektroden hergestellt, indem auf ein Titansubstrat eine Supportschicht mit unterstöchiometrischem Titanoxid eingesintert wurde, auf welchem wiederum das Iridium galvanisch gepulst abgeschieden wurde. Die Beladung mit Katalysatormaterial war hier geringer als der der Stand der Technik, doch die katalytische Aktivität wurde durch die optimierte Elektrodenarchitektur erhöht. In dieser Arbeit wurden die Elektroden einem elektrochemischen Degradationsprotokoll unterzogen, welches sich aus Cyclovoltametrie (CV) gefolgt von Chronopotentiometrie (CP) und Chronoamperometrie, mit wechselnden Potentialen, zusammensetzt. Der dabei verwendete Elektrolyt wurde ebenfalls durch Filtration und Titration auf Zerfallsprodukte der Elektroden hin untersucht. Nach erfolgter Degradation wurden die Elektroden auf topografische Änderungen, mittels Rasterelektronenmikroskop (REM), Änderungen der Kristallinität, mittels Röntgendiffraktometrie (XRD) und Änderungen der Elementenkonzentration durch Röntgenfluoreszenzspektroskopie (XRF) hin untersucht.
Carbon Nanofibers (CNF) are considered to be a promising catalyst support material due to their unique characteristics, excellent mechanical, electrical and structural properties, high surface area and nevertheless, good interaction with metallic catalyst particles. The possibility of preparing CNF decorated with platinum by an electrochemical method was tested, using a hexachloroplatinic bath solution. The experiments were carried out with the aid of a Potentiostat/Galvanostat Ivium Technologies Vertex, in a three – electrode cell. The aim of the present work was to determine the electrochemical surface area (ECSA) of the CNF-Pt catalysts in relation to the functionalization treatment of fibers, using an electrochemical method. ECSA for different functionalized CNF-Pt catalysts was determined by cyclic voltammetry in 0.5 M H2SO4 solution. The highest active surface of platinum was obtained for the samples with CNF functionalized by plasma treatment using 80 W for 1800 s. The obtained results correlate very well with the particles size and distribution of platinum, revealed by scanning electron microscopy (SEM) and the quantity of deposited platinum determined by thermo gravimetrical analysis (TGA) respectively. Cyclic voltammetry (CV) has been proven to be a suitable method for estimation of the ECSA of the electrocatalysts.
Platinum is one of the most effective electro catalysts for PEMFCs (proton exchange membrane fuel cells), but because of its prohibitive price, the use of this metal in industrial purposes is limited. As a consequence, during last years, several materials have been investigated, in order to obtain an efficient catalyst for both ORR (oxygen reduction reaction) and HOR (hydrogen oxidation reaction), which can replace the expensive platinum but preserving the same properties: high electrical conductivity, structural stability and good corrosion resistance. Moreover, one of the most important parameters for catalyst materials is the electrochemical surface area (real surface area), which has a strong influence on the reaction rate and also on the current density.
CNFs (carbon nanofibers) are considered to be a promising catalyst support material due to their unique characteristics, excellent mechanical, electrical and structural properties, high surface area and nevertheless, good interaction with platinum particles.
The possibility of preparing CNFs decorated with platinum by electrochemical methods was tested, using a hexachloroplatinic solution bath. The experiments were carried out with the aid of a Potentiostat/Galvanostat MMate 510, in a three – electrode cell.
The aim of the present work was to determine the electrochemical surface area of the CNFs – Pt catalysts, using an electrochemical method. The obtained results correlate very well with the particles size and distribution of platinum, analyzed by SEM (scanning electron microscopy) respectively with the quantity of deposited platinum determined by TG (thermo gravimetrical analyses). Cyclic voltammetry is a suitable method for estimation of the real surface area for catalyst particles.
The present paper presents one- and two-step approaches for electrochemical Pt and Ir deposition on a porous Ti-substrate to obtain a bifunctional oxygen electrode. Surface pre-treatment of the fiber-based Ti-substrate with oxalic acid provides an alternative to plasma treatment for partially stripping TiO2 from the electrode surface and roughening the topography. Electrochemical catalyst deposition performed directly onto the pretreated Ti-substrates bypasses unnecessary preparation and processing of catalyst support structures. A single Pt constant potential deposition (CPD), directly followed by pulsed electrodeposition (PED), created nanosized noble agglomerates. Subsequently, Ir was deposited via PED onto the Pt sub-structure to obtain a successively deposited PtIr catalyst layer. For the co-deposition of PtIr, a binary PtIr-alloy electrolyte was used applying PED. Micrographically, areal micro- and nano-scaled Pt sub-structure were observed, supplemented by homogenously distributed, nanosized Ir agglomerates for the successive PtIr deposition. In contrast, the PtIr co-deposition led to spherical, nanosized PtIr agglomerates. The electrochemical ORR and OER activity showed increased hydrogen desorption peaks for the Pt-deposited substrate, as well as broadening and flattening of the hydrogen desorption peaks for PtIr deposited substrates. The anodic kinetic parameters for the prepared electrodes were found to be higher than those of a polished Ir-disc.
The membrane electrode assemblies (MEA) for polymer electrolyte membrane fuel cells (PEMFC) developed at the Westphalian Energy Institute are based on oxygen plasma activated carbon nanotubes (CNT) doped with platinum particles. For electrode preparation an ink is used containing the activated CNTs as well as hydrophobic and hydrophilic material in solved form. After this ink is sprayed onto a graphitic substrate platinum particles are deposited by pulse plating method, where the plasma activation enhances CNT dispersibility as well as platinum deposition. This materials mixture is structured in nanoscale with the aim to increase the catalyst particles’ specific surface. For low reactance at operation, homogeneous compression of the MEA’s layers is necessary within a PEMFC. A novel stack architecture for electrochemical cells, especially PEMFC as well as PEM electrolysers, has been developed in order to achieve ideal cell operation conditions. Single cells of such a stack are inserted into flexible slots that are surrounded by a hydraulic medium which is pressurised during operation in order to achieve an even compression and cooling of the stack’s cells. With this stack design it has been possible to construct a test facility for simultaneous characterisation of several MEA samples. As compression and temperature conditions of every single sample are the same, the effects of e.g. different electrode configurations can be investigated with the novel test system.
Building Information Modeling (BIM) wird im Bauwesen immer stärker gefordert. Der vorliegende Artikel befasst sich mit dem Datenaustausch für die TGA. Am Beispiel eines RLT-Gerätes werden der Detaillierungsgrad und der Datenaufbau mit IFC erläutert. Insbesondere zeigt sich hierbei, dass der Datenimport aufgrund fehlender Standards und Definitionen mit Datenverlust einhergeht. Damit ergibt sich ein Auftrag an die Softwareunternehmen hier für eindeutige Standards zu sorgen.
In the polymer electrolyte membrane fuel cells (PEMFC) state of the art, rare and expensive platinum group metals (PGM) or PGM alloys are used as catalyst material. Reduction of PGMs in PEMFC electrodes is strongly required to reach cost targets for this technology. An optimal catalyst utilization is achieved in case of nano-structured particles supported on carbon material with a large specific surface area. In this study, graphitic material, in form of carbon nanofibers (CNF), is decorated with Pt particles, serving as catalyst material for PEMFC electrodes with low Pt loading. As a novelty, the effect of oxygen plasma treatment of CNFs previously to platinum particle deposition has been studied. Electrodes are investigated in respect of the optimal morphology, microstructure as well as electrochemical properties. Therefore, samples are characterized by means of scanning electron microscopy combined with energy dispersive X-ray analysis, transmission electron microscopy, thermogravimetry, X-ray diffraction as well as X-ray fluorescence analysis. In order to determine the electrochemical active surface area of catalyst particles, cyclic voltammetry has been performed in 0.5 M sulphuric acid. Selected samples have been investigated in a PEMFC test bench according to their polarization behavior.
In state of the art polymer electrolyte membrane fuel cells (PEMFC) rare and expensive platinum group metals (PGM) are used as catalyst material. Reduction of PGM in PEMFC electrodes is strongly required to reach cost targets for this technology. An optimal catalyst utilisation is achieved in the case of nano-structured particles supported on carbon material with a large specific surface area. In this study, graphitic material in form of carbon nanofibres (CNFs) is decorated with platinum (Pt) particles serving as catalyst material for PEMFC electrodes with low Pt loading. For electrode preparation CNFs have been previously activated by means of radio frequency induced oxygen plasma. This kind of treatment results in formation of functional groups on the CNF’s surface which directly influences the characteristics of subsequent Pt particle deposition. Different plasma parameters (plasma power, gas flow or exposure time) have to be set in order to achieve formation of oxygen containing functional groups (hydroxylic, carboxylic or carbonylic) on the CNF’s surface. In the frame of this experimental work, electrodes are investigated in respect of optimal morphology, microstructure as well as electrochemical properties. Therefore, samples were characterised by means of scanning electron microscopy combined with energy dispersive X-ray analysis, transmission electron microscopy, thermogravimetry, X-ray diffraction, X-ray fluorescence as well as polarisation measurements.
Für einen Energiesektor, der zukünftig im hohen Maße auf erneuerbaren Quellen beruht, sind Energiespeicher unverzichtbar, um die heute gewohnte Versorgungssicherheit auch in Zeiten geringer Einspeisung aus Wasser, PV- und/oder Windkraftanlagen garantieren zu können. Da konventionelle Speichertechnologien wie beispielsweise Pumpspeicherkraftwerke durch fehlende mögliche Standorte in Deutschland nicht weiter ausgebaut werden, sind Alternativen notwendig. Es ist Konsens, hierfür emissionsarme Strategien zu entwickeln, um die gesetzten Ziele zur Reduktion von CO2 Emissionen zu erreichen. Neben Batterien, die vorzugsweise für Kurzzeitspeicher einzusetzen sind, bietet sich Wasserstoff als umweltfreundlicher Sekundärenergieträger an, der in großen Mengen gespeichert und in Brennstoffzellen mit hohem Wirkungsgrad emissionsfrei in elektrische Energie umgewandelt werden kann. Da elementarer Wasserstoff nicht natürlich vorkommt, ist dieser zuvor zu generieren. Überschüsse aus regenerativen Energiequellen können hierfür ideal genutzt werden. In diesem Beitrag wird ein aussichtsreiches Konzept für einen modularen Hochdruckelektrolyseur vorgestellt, welcher erlaubt, Wasserstoff bei einem hohen Ausgangsdruck bereitzustellen. Durch den prinzipiellen Aufbau, ist ein beliebiges Druckniveau am Ausgang nur von der mechanischen Stabilität der verwendeten Bauteile abhängig. Hierdurch ist es möglich, Wasserstoff direkt in einen Druckgasspeicher oder eine Pipeline zu produzieren, ohne einen zusätzlichen Verdichter nutzen zu müssen. Dies resultiert in signifikanten Kosteneinsparungen und verbessert den Systemwirkungsgrad zukünftiger Anlagen entscheidend.
Um grünen Wasserstoff effizient als Energieträger nutzen zu können, ist die Entwicklung von haltbaren und aktiven Katalysatorschichten für Brennstoffzellen und Elektrolyseuren von äußerster Wichtigkeit. Eine große Herausforderung ist, dass konventionelle C/Pt-Katalysatoren eine starke Korrosionsreaktion durchlaufen und mit hohen Kosten verknüpft sind. Weswegen alternative Kohlenstoffträger wie Kohlenstoffnanofaser-Materialien entwickelt wurden, welche eine längere Haltbarkeit aufweisen können. In dieser Arbeit wurde die Aufbringung von Pt- und Ir-Nanopartikeln auf gesponnene Kohlenstoffnanofaser-Vliese untersucht. Es wurden erstmals in einer Flüssigkeit laserablatierte Pt-Nanoartikel mit einem PAN-Vlies versponnen oder in einem zweiten Syntheseverfahren auf ein Vlies aufgesprüht. Diese Methoden wurden mit der gepulsten galvanischen Abscheidung von Pt auf einem PAN-Vlies verglichen. Die Vliese wurden bezüglich ihres Graphitisierungsgrades, ihrer Partikelverteilung und ihrer Beständigkeit untersucht, einschließlich des Einflusses der Karbonisierungstemperatur. Die Raman- und XRF-Messungen ergaben eine Erhöhung des Graphitisierungsgrades und eine Abnahme der PAN-Reste mit dem Anstieg der Karbonisierungstemperatur. Elektrochemische Messungen und REM-Aufnahmen bestätigten die erfolgreiche Synthese von langzeitstabilen CNF-Vliesen mit einer hohen massenspezifischen aktiven Platinoberfläche und einer guten Nanopartikelverteilung. Diese Ergebnisse tragen zur Entwicklung von ökologischen und ökonomischen Katalysatorschichten bei.
RLT-Geräte werden meist auf eine Lebensdauer von 15 Jahren ausgelegt. Die Erfahrung zeigt jedoch, dass viele Anlagen mehr oder weniger unverändert bis zu 25 Jahren betrieben werden. Damit müssen aktuell projektierte RLT-Anlagen auch bei dem erwarteten Klimawandel die gewünschten Zuluftparameter (Temperatur und Luftfeuchte) einhalten. Der Artikel untersjucht den einfluss des Klimawandels für Deutschland bezogen auf die Klimatisierung einer exemplarischen Krankenhausintensivstation.
Gebäude sind immer auch ein Ausdruck der Zeit, in der sie erbaut wurden. Oft bleiben sie sehr lange erhalten und erfahren über die Jahrzehnte mehrfache Nutzungsänderungen. Betroffen sind alte Produktionshallen ebenso wie Verwaltungsimmobilien. Die Gebäudehülle bleibt bei einer Umnutzung meist unangetastet. Aufgabe der Technischen Gebäudeausrüstung ist es dann, das Raumklima für die Nutzer unter den geänderten Bedingungen behaglich zu gestalten und die Aspekte der Energieeffizienz und Nachhaltigkeit nicht aus den Augen zu verlieren. Insbesondere die Kühlung der Gebäude im Sommer steht aufgrund der steigenden internen Lasten und der solaren Gewinne durch große Glasfassaden im Vordergrund.
Am Beispiel eines rund 100 Jahre alten Verwaltungsgebäudes wird gezeigt, wie eine dynamischen Kühllastberechnung eine exakte Voraussage der zu erwartenden Spitzenlasten ermöglicht. Darauf basierend kann dann eine individuelle RLT-Anlagentechnik installiert wird. Die Auslegung erfolgt mit zwei Versionen der VDI 2078. Die Ergebnisse werden miteinander verglichen.
Am Beispiel eines rund 100 Jahre alten Verwaltungsgebäudes wird gezeigt, wie eine dynamische Kühllastberechnung eine exakte Voraussage der zu erwartenden Spitzenlasten ermöglicht. Darauf basierend kann dann eine individuelle RLT-Anlagentechnik installiert werden. Die Auslegung erfolgt mit zwei Versionen der VDI 2078. Die Ergebnisse werden miteinander verglichen.
Various aqueous citrate electrolyte compositions for the Ni-Mo electrodeposition are explored in order to deposit Ni-Mo alloys with Mo-content ranging from 40 wt% to 65 wt% to find an alloy composition with superior catalytic activity towards the hydrogen evolution reaction (HER). The depositions were performed on copper substrates mounted onto a rotating disc electrode (RDE) and were investigated via scanning electron microscopy (SEM), X-ray fluorescence (XRF) and X-ray diffraction (XRD) methods as well as linear sweep voltammetry (LSV) and impedance spectroscopy. Kinetic parameters were calculated via Tafel analysis. Partial deposition current densities and current efficiencies were determined by correlating XRF measurements with gravimetric results. The variation of the electrolyte composition and deposition parameters enabled the deposition of alloys with Mo-content over the range of 40-65 wt%. An increase in Mo-content in deposited alloys was recorded with an increase in rotation speed of the RDE. Current efficiency of the deposition was in the magnitude of <1%, which is characteristic for the deposition of alloys with high Mo-content. The calculated kinetic parameters were used to determine the Mo-content with the highest catalytic activity for use in the HER.
Die Klimatisierung von Gebäuden gewinnt zunehmend an Bedeutung. Dies liegt zum einen an der Bauweise und Nutzung, die höhere Kühllasten mit sich bringt. Zum anderen fordern die Nutzer eine angemessene Behaglichkeit bei hoher Luftqualität.
Diese Forderungen gehen einher mit hoher Energieeffizienz und einwandfreier Hygiene der Raum-lufttechnischen Anlagen. Dieser Beitrag untersucht diese Forderungen für Nichtwohngebäude und prüft, ob Hygiene und Energieeffizienz zu Zielkonflikten führen können.
Der Mensch verbringt einen Großteil seiner Zeit in geschlossenen Räumen und erwartet, dass die Luftqualität mindestens der Außenluft entspricht. Mit Blick auf die aktuelle Feinstaubdebatte, muss die Raumluftqualität noch deutlich darüber hinaus gehen. Weiterhin soll der Aufenthalt am Arbeitsplatz nicht zu gesundheitlichen Beeinträchtigungen führen (Reizung der Schleimhäute, trockene Augen oder virale Infektionen).
Die Klimatisierung von Gebäuden benötigt einen nicht unerheblichen Teil der Primärenergie, so dass ein effizienter Anlagenbetrieb ein wichtiger Baustein der Energiewende ist. Dabei spielt die Nutzung von regenerativen Energien (Solarstrom zur Gebäudekühlung) genauso eine wichtige Rolle wie die Optimierung von Komponenten und deren Abstimmung zum „System Gebäudeklimatisierung“.
Zur Einordnung der Themengebiete werden die relevanten Normen und Regelwerke auf europäischer und deutscher Ebene kurz vorgestellt und erläutert.
Am Beispiel eines typischen RLT-Gerätes werden die Komponenten und Funktionen im Betrieb veranschaulicht. Die wichtigsten Komponenten (z. B. Filter, Wärmeübertrager, Befeuchter und Ventilatoren) werden mit Blick auf Hygiene und Energieeffizienz anschließend analysiert und verglichen. Die Vergleiche finden anhand von Fallbeispielen statt, wie sie für Nichtwohngebäude typisch sind. Zusammenfassend wird die Ausgangsfrage aus Sicht des Autors beantwortet.
Diese Arbeit befasst sich mit der Entwicklung einer Titanträgerlage, die anschließend als Supportstruktur für den Anodenkatalysator eines PEM-Elektrolyseurs genutzt werden soll, sowie mit der Parametrisierung der hierfür genutzten Lasersinteranlage.
Dafür wird 1 mg cm-2 unterstöchiometrisches Titanoxid (TiOx) auf eine poröse Titantransportschicht gesprüht und anschließend mit einem gepulsten Laser in Argonatmosphäre gesintert, um beide Materialien zu verbinden und die Oberfläche gezielt verändern zu können. Da die benötigte Menge des unterstöchiometrischen TiOx-Pulvers nicht abschätzbar war, wurden die Arbeiten mit kommerziell verfügbarem Titandioxid-(TiOx) Pulver durchgeführt.
Im ersten Schritt wurde ein bestehender Sprühprozess optimiert. Der Fokus lag dabei auf einem gleichmäßigen Sprühergebnis und dem reproduzierbaren Erreichen einer vorgegebenen Beladung. Die Optimierung wurde auf Titanblech und auf porösen Titansubstraten durchgeführt.
Anschließend wurde das verwendetet Lasersystem, das einen luftgekühlten Neodymdotierten Yttrium-Aluminium-Granat (Nd:YAG)-Festkörperlaser mit einer Wellenlänge von 355 nm nutzt, parametrisiert. Das Erreichen der Bearbeitungsschwelle und die maximalen Spotgrößen bei verschiedenen Diodenströmen wurden untersucht. Anschließend wurde die Frequenz erhöht, dies führte zu geringeren Einzelpulsenergien und daher zu neuen Bearbeitungsschwellen bei den unterschiedlichen Diodenströmen. Die Variierung des Vorschubs führt zu einer Änderung der eingebrachten Energie pro Fläche und wirkt sich direkt auf die Sinterdauer aus. Als letztes wurde der Einfluss des Linienabstandes untersucht. Wenn der Linienabstand unterhalb des Wertes gehalten wird, ab dem eine streifenfreie Oberfläche entsteht, wirkt die Verkleinerung des Linienabstandes wie die Verringerung des Vorschubs.