Refine
Year of publication
- 2019 (14) (remove)
Document Type
- Article (14) (remove)
Language
- English (14) (remove)
Keywords
- Rwanda (1)
- academic and job-related self-control demands (1)
- composition (1)
- design process (1)
- farming (1)
- gender stereotypes (1)
- gender-sensitive design (1)
- gender-specific design (1)
- irritation (1)
- study and working time per week (1)
- trait self-control (1)
- transport (1)
Institute
We study a quantum two-level system under the influence of two independent baths, i.e., a sub-Ohmic pure dephasing bath and an Ohmic or sub-Ohmic relaxational bath. We show that cooling such a system invariably polarizes one of the two baths. A polarized relaxational bath creates an effective asymmetry. This asymmetry can be suppressed by additional dephasing noise. This being less effective, the more dominant low frequencies are in the dephasing noise. A polarized dephasing bath generates a large shift in the coherent oscillation frequency of the two-level system. This frequency shift is little affected by additional relaxational noise nor by the frequency distribution of the dephasing noise itself. As our model reflects a typical situation for superconducting phase qubits, our findings can help optimize cooling protocols for future quantum electronic devices.
In this research computer tomography (CT) iterative reconstruction (IR) algorithms are investigated, specifically the impact of their statistical and model-based strength on image quality in low-dose lung screening CT protocols in comparison to filtered back projection (FBP). It has been probed whether statistical, model-based IR in conjunction with low-dose, and ultra-low-dose protocols are suitable for lungcancer screening. To this end, artificial lung nodules shaped as spheres and spicules made from material with calibrated Hounsfield units (HU) were attached on marked positions in the lung structure of an anthropomorphic phantom. Nodule positions were selected by distinguished radiologists. The phantom with nodules was scanned on a CT Scanner using standard high contrast (SHC), low-dose (LD) and ultra low-dose (ULD) protocol. For reconstruction FBP and the IR algorithm ADMIRE at three different …
The purpose of this work was to develop and investigate a radiofrequency (RF) coil to perform image studies on small animals using the 7T magnetic resonance imaging (MRI) system, installed in the imaging platform in the autopsy room (Portuguese acronym PISA), at the University of Sao Paulo, Brazil, which is the unique 7T MRI scanner installed in South America. Due to a high demand to create new specific coils for this 7T system, it is necessary to carefully assess the distribution of electromagnetic (EM) fields generated by the coils and evaluate the patient/object safety during MRI procedures. To achieve this goal 3D numerical methods were used to design and analyse a 8-rungs transmit/receive linearly driven birdcage coil for small animals. Calculated magnetic field (B 1) distributions generated by the coil were crosschecked with measured results, indicating good confidence in the simulated results.
In this paper, the effect of computed tomography (CT) values of metals in 12-bit and 16-bit extended Hounsfield Unit (EHU) scale on dose calculations in radiotherapy treatment planning systems (TPS) were quantified. Dose simulations for metals in water environment were performed with the software PRIMO in 6MV photon mode. The depth dose profiles were analysed and the relative dose differences between the metals determined with 12-bit and 16-bit CT imaging, respectively, were calculated. Maximum dose differences of ΔAl= 3.0%, ΔTi= 4.5%, ΔCr= 6.2% and ΔCu= 11.6% were measured. In order to increase the accuracy of dose calculation on patients with implants, CT imaging in the EHU scale is recommended.