Filtern
Erscheinungsjahr
Dokumenttyp
- Wissenschaftlicher Artikel (237) (entfernen)
Sprache
- Englisch (237) (entfernen)
Schlagworte
- CDK (2)
- Deep Learning (2)
- OCSR (2)
- Polymer-Elektrolytmembran-Brennstoffzelle (2)
- hydraulic compression (2)
- modular stack design (2)
- open quantum systems (2)
- water electrolysis (2)
- carbon nanofibers, platinum electrodeposition, ele ctrochemical surface area (1)
- 360 degree Feedback (1)
- AI (1)
- Additive manufacturing Directed energy deposition-arc 316L stainless steel Corrosion behavior Electrochemical corrosion (1)
- Aerosol (1)
- Aggregation-prone (1)
- Amylase, Enzymcharakterisierung (1)
- Anorganische Analyse (1)
- Assessment Center (1)
- Augmented (1)
- Augmented Electromagnetic Accelerators (1)
- Augmented Multiphase (1)
- Augmented Multiphase Rail Launcher (1)
- Augmented Three-Phase AC-Railgun (1)
- Biomechanics (1)
- Biomedical monitoring, Hospitals, Electrocardiography, Wireless communication, Patient monitoring, Wireless sensor networks (1)
- Bone morphogenetic protein 2 (1)
- Carboxylate (1)
- Case-Study (1)
- Catalysis (1)
- Cell-free implant (1)
- Chemical image depiction (1)
- Chemical space (1)
- Cheminformatics (1)
- Chemistry Development Kit (1)
- Chemistry Development Kit, CDK, Molecule fragmentation, In silico fragmentation, Scaffolds, Functional groups, Glycosidic moieties, Rich client, Graphical user interface, GUI (1)
- Clustering (1)
- Cr(VI) and Zn(II) cations (1)
- DECIMER (1)
- Data Collection (1)
- Depiction generator image augmentation (1)
- Dissipative particle dynamics, DPD, Surfactant, Bilayer, Lamellar, Simulation, Mesoscopic (1)
- E. coli SHuffle® T7 (1)
- Electrodeposition (1)
- Electrolysis (1)
- Electromagnetic Launcher (1)
- Energy Storage Mode (1)
- Erweiterte Realität <Informatik> (1)
- Europe (1)
- Evidence-based Management (1)
- Flügelform (1)
- Fragmentation (1)
- Gas Diffusion Electrode (1)
- Greek dept crisis (1)
- Hand-drawn chemical structures (1)
- Homogene Kühlung (1)
- Hydraulic cell compression (1)
- Hydrogen evolution reaction (1)
- Hydrophilicity enhanced hBMP2 variant (1)
- ICP-Massenspektrometrie (1)
- Implantat (1)
- In-silico-design (1)
- Indigo (1)
- Kernspintomografie (1)
- Laser Synthesis Electrocatalytic Water Splitting (1)
- Leadership Competencies (1)
- Linear Electromagnetic Accelerator (1)
- Lüftungsanlage (1)
- MITRE (1)
- Magnetic Pressure (1)
- Mapping (1)
- Membrane (1)
- Methodology (1)
- Modular Augmented Launcher (1)
- Modular Design (1)
- Multiphase Rail Launcher (1)
- Mund-Nasen-Schutz (1)
- Muzzle Velocity (1)
- N,N,O Ligands (1)
- N,N′ Ligands (1)
- Natural products (1)
- NiCrBSi coatings; flame spraying; induction remelting; wear resistance (1)
- Normalisierung (1)
- OCSR, Optical Chemical Structure Recognition (1)
- ORR OER (1)
- OSINT (1)
- Ohrwurm (1)
- PEM electrolysis (1)
- PEM fuel cell (1)
- PEM fuel cell electrocatalysts, Carbon nanofibers, Oxygen plasma activation, Pulsed electroplating. (1)
- PEM water electrolysis (1)
- PEMWE (1)
- Physics-informed deep learning; unsupervised learning; Reynolds-averaged Navier-Stokesequations; high Reynolds number flow; turbulence modeling (1)
- Politische Berichterstattung (1)
- Polymere (1)
- Porous Transport Layers (1)
- Powder feed rate HVOF Cermet Wear Corrosion (1)
- PtCoMn (1)
- RDKit (1)
- Rail Launcher (1)
- Railgun (1)
- Rwanda (1)
- SARS-CoV-2 (1)
- Scaffold (1)
- Scaffold network (1)
- Scaffold tree (1)
- Segmentation; Correlation; Diseases; Convolutional Neural Networks (1)
- Semi-Infinite Plate (1)
- Social Innovation (1)
- Spondylodese (1)
- Stack <Brennstoffzelle> (1)
- Stellite 6; HVOF-spraying; Laser remelting; Cavitation erosion; Coatings (1)
- Ternary alloy catalyst preparation (1)
- Thermal Performance (1)
- Titanium; Al2O3–TiO2 coatings; Nanoindentation (1)
- Transformer (1)
- Twitter (1)
- Twitter <Softwareplattform> (1)
- Upscaling laboratory models (1)
- Zinc (1)
- academic and job-related self-control demands (1)
- activated sludge (1)
- additive manufacturing; polylactic acid (PLA); fused filament fabrication (FFF); fused deposition modeling (FDM); printing temperature; filament color; dimensional accuracy; tensile strength; friction performance; wear (1)
- adhesion (1)
- advanced persistent threats (1)
- aerosol (1)
- air hygiene (1)
- airborne infection (1)
- antecedents (1)
- artificial intelligence (1)
- assistive robotics (1)
- augmented reality (1)
- bacterial toxicity (1)
- balance (1)
- barrel cortex, cell types, multielectrode recordings, perception, psychophysics (1)
- bio-inspired functional surface (1)
- bioinspired (1)
- biomimetic (1)
- biomimetic materials (1)
- biomimetics; functional morphology; plant biomechanics; plant motion; strain analysis; structure–function relationship; 3D digital image correlation (3D-DIC); Hakea sericea; Hakea salicifolia (1)
- biomimicry (1)
- bipolar plate (1)
- blockchain (1)
- bloxberg (1)
- carbon nanofibers, platinum electrodeposition, electrocatalysts (1)
- cartilage defect (1)
- cartilage regeneration (1)
- chlorinated phenols (1)
- co-based alloys; hot corrosion; solid particle erosion; microstructure; brazing (1)
- coatings (1)
- cobot (1)
- compassionate love (1)
- composition (1)
- conical intersection (1)
- corrosion resistance (1)
- corrosion; self-fluxing alloys; NiCrBSi; WC-12Co; cavitation; hard metals (1)
- cyber kill chain (1)
- demagnetization cooling (1)
- design process (1)
- diversity (1)
- dlt (1)
- dynamic capabilities (1)
- education; skills; competences; pandemic; online or face-to-face (1)
- efficiency of exciton transfer (1)
- empowerment (1)
- entrepreneurial diversity (1)
- entrepreneurship (1)
- ethereum (1)
- ethics (1)
- excitation energy transfer (1)
- expert interviews (1)
- face mask (1)
- farming (1)
- fused deposition modeling (FDM); fused filament fabrication (FFF); polylactic acid (PLA); layer height; layer thickness; filament color; PLA color; dimensional accuracy; tensile strength (1)
- gender stereotypes (1)
- gender-sensitive design (1)
- gender-specific design (1)
- human robot interaction (1)
- human-robot collaboration (1)
- hydraulic cell compression (1)
- innovation (1)
- international comparative study (1)
- intersectionality (1)
- irritation (1)
- long-term toxicity (1)
- luminescent bacteria (1)
- machine learning (1)
- managerial vs. non-managerial actors (1)
- measurement study (1)
- media accountability (1)
- microfoundations (1)
- multi-level model of competence (1)
- narcissism (1)
- neutrality (1)
- nonadiabatic dynamics (1)
- noncommuting fluctuations (1)
- nonequilibrium quantum transport (1)
- normalisation (1)
- novel (1)
- open science (1)
- optical chemical structure recognition (1)
- pH-shift elution (1)
- phishing (1)
- poa (1)
- poe (1)
- political journalism (1)
- polymer electrolyte membrane (1)
- product development (1)
- projection (1)
- quality standards (1)
- quantum dissipation (1)
- reconnaissance (1)
- relevance (1)
- respiration inhibition (1)
- role identity (1)
- self-fluxing; ZrO2; NiCrBSi; vacuum post-treatment; thermal spraying (1)
- servant leadership (1)
- shared user control (1)
- solution finding (1)
- study and working time per week (1)
- television news coverage (1)
- trait self-control (1)
- transport (1)
- tree frog (1)
- ventilation (1)
- vibronic coupling (1)
- virtual reality (1)
- visual cues (1)
- visualization techniques (1)
- watchblogs (1)
- Änderung (1)
Institut
- Westfälisches Institut für Gesundheit (38)
- Westfälisches Energieinstitut (35)
- Wirtschaft und Informationstechnik Bocholt (32)
- Elektrotechnik und angewandte Naturwissenschaften (28)
- Institut für biologische und chemische Informatik (19)
- Maschinenbau und Facilities Management (13)
- Wirtschaftsingenieurwesen (13)
- Maschinenbau Bocholt (12)
- Institut Arbeit und Technik (7)
- Informatik und Kommunikation (6)
- Institut für Internetsicherheit (6)
- Institut für Innovationsforschung und -management (4)
- Wirtschaftsrecht (3)
- Fachbereiche (2)
- Institute (1)
- Mechatronik-Institut Bocholt (1)
Analysis of future development opportunities for OIS (Office Information Systems) methods and tools.
(1992)
Stereotactic frame systems are widely used in neurosurgery. The accuracy of frame devices is considered as a gold standard to which the accuracy of new frameless stereotactic navigation systems is compared. The purpose of this study is to develop a general approach for the prediction of the application accuracy of stereotactic systems. The approach will be applied to the frame‐based biopsy performed with three frame devices: Leksell G, Cosman–Roberts–Wells (CRW), and Brown–Roberts–Wells (BRW). A work‐flow analysis will be carried out demonstrating that the accuracy relevant for a clinical application comprises several error sources including imaging, target and entry point selection, image to frame coordinates registration, and the setting of mechanical parameters of the frame. These error sources will be postulated to obey a Gaussian distribution probability density. The linear, i.e., Gaussian, error propagation, will be used to link all error contributions thus to calculate the cumulative accuracy of the frame used in the application. Although the Gaussian approach is an approximation, it allows for an analytical treatment of the accuracy. Both the accuracy at the target point and the accuracy of the probe needle guidance along the planned trajectory have been investigated. Of great significance is the relationship found between accuracy, pixel dimension, and image slice thickness, the latter being the dominant factor for slices of more than 1.5 mm thickness, yielding inaccuracies larger than 1.5 mm. For target points the predictions for the application accuracy have been compared to the results of measurements, showing good agreement with the experimental data.
A qualitative work‐flow analysis of a neurosurgical procedure indicates that the resolution of the image used to plan the intervention is the major source of inaccuracy. Quantitative experimental measurements confirm this observation. They fail, however, to explain the relationship between the accuracy of the frame components involved in a stereotactic procedure and the overall application accuracy. This investigation shows that the novel Gaussian approach is a flexible framework for the calculation of the application accuracy of frame systems. Therefore, the Gaussian approach provides a detailed understanding of the interplay between the various factors affecting accuracy. The basic ideas and limitations of the Gaussian approach are briefly explained. The effect of fiducial marker distribution and registration is investigated and shown to introduce a spatial dependence to the accuracy. The results of the Gaussian approach are compared with experimental data for three stereotactic frame devices: Leksell G, Cosman–Roberts–Wells, and Brown–Roberts–Wells. Although the Gaussian approach is an approximation, it reproduces the accuracy measured in the experiment within the statistical error of that experiment. Comp Aid Surg 4:77–86 (1999). © 1999 Wiley‐Liss, Inc.
Three-dimensional magnetic resonance medical images may contain scanner- and patient-induced geometric distortion. For qualitative diagnosis, geometric errors of a few millimeters are often tolerated. However, quantitative applications such as image-guided neurosurgery and radiotherapy can require an accuracy of a millimeter or better. We have developed a method to accurately measure scanner-induced geometric distortion and to correct the MR images for this type of distortion. The method involves a number of steps. First, a specially designed phantom is scanned that contains a large number of reference structures on positions with a manufacturing error of less than 0.05 mm. Next, the positions of the reference structures are automatically detected in the scanned images and a higher-order polynomial distortion-correction transformation is estimated. Then the patient is scanned and the transformation is applied to correct the patient images for the detected distortion. The distortion-correction method is explained in detail in this paper. The accuracy of the method has been measured with synthetically generated phantom scans that contain an exactly-known amount and type of distortion. The reproducibility of the method has been measured by applying it to a series of consecutive phantom scans. Validation results are briefly described in this paper, a more-detailed description is given in another submission to SPIE Medical Imaging 2001.