Filtern
Erscheinungsjahr
Dokumenttyp
- Wissenschaftlicher Artikel (237) (entfernen)
Sprache
- Englisch (237) (entfernen)
Schlagworte
Institut
- Westfälisches Institut für Gesundheit (38)
- Westfälisches Energieinstitut (35)
- Wirtschaft und Informationstechnik Bocholt (32)
- Elektrotechnik und angewandte Naturwissenschaften (28)
- Institut für biologische und chemische Informatik (19)
- Maschinenbau und Facilities Management (13)
- Wirtschaftsingenieurwesen (13)
- Maschinenbau Bocholt (12)
- Institut Arbeit und Technik (7)
- Informatik und Kommunikation (6)
The activated sludge respiration inhibition test and the luminescent bacteria test with Vibrio fischeri are important bacterial test systems for evaluation of the toxicity of chemical compounds. These test systems were further optimized to result in better handling, reliability and sensitivity. Concerning the Vibrio fischeri test, media components such as yeast extract and bivalent cation concentrations like Ca2+ and Mg2+ were optimized. The cultivation, storage conditions and reactivation process of the stored bacteria were also improved, which enabled simpler handling and led to good reproducibility. Additionally, the respiration inhibition test with a prolonged incubation time was further analyzed using different chlorinated phenols as reference compounds. It could be stated that a longer incubation period significantly improved the sensitivity of the test system.
Stereotactic frame systems are widely used in neurosurgery. The accuracy of frame devices is considered as a gold standard to which the accuracy of new frameless stereotactic navigation systems is compared. The purpose of this study is to develop a general approach for the prediction of the application accuracy of stereotactic systems. The approach will be applied to the frame‐based biopsy performed with three frame devices: Leksell G, Cosman–Roberts–Wells (CRW), and Brown–Roberts–Wells (BRW). A work‐flow analysis will be carried out demonstrating that the accuracy relevant for a clinical application comprises several error sources including imaging, target and entry point selection, image to frame coordinates registration, and the setting of mechanical parameters of the frame. These error sources will be postulated to obey a Gaussian distribution probability density. The linear, i.e., Gaussian, error propagation, will be used to link all error contributions thus to calculate the cumulative accuracy of the frame used in the application. Although the Gaussian approach is an approximation, it allows for an analytical treatment of the accuracy. Both the accuracy at the target point and the accuracy of the probe needle guidance along the planned trajectory have been investigated. Of great significance is the relationship found between accuracy, pixel dimension, and image slice thickness, the latter being the dominant factor for slices of more than 1.5 mm thickness, yielding inaccuracies larger than 1.5 mm. For target points the predictions for the application accuracy have been compared to the results of measurements, showing good agreement with the experimental data.