Design and Development of a Bioreactor System for Mechanical Stimulation of Musculoskeletal Tissue
(2023)
We report on the development of a bioreactor system for mechanical stimulation of musculoskeletal tissues. The ultimate object is to improve the quality of medical treatment following injuries of the enthesis tissue. To this end, the tissue formation process through the effect of mechanical stimulation is investigated. A six-well system was designed, 3D printed and tested. An integrated actuator creates strain by applying a force. A contactless position sensor monitors the travels. An electronic circuit controls the bioreactor using a microcontroller. An IoT platform connects the microcontroller to a smartphone, enabling the user to alter variables, trigger actions and monitor the system. The system was stabilised by implementing two PID controllers and safety measures. The results show that the bioreactor design is suited to execute mechanical stimulation and to investigate the tissue formation and regeneration process …
Cone-Beam computed tomography (CBCT) has become the most important component of modern radiotherapy for positioning tumor patients directly before treatment. In this work we investigate alternations to standard acquisition protocol, called preset, for patients with a tumor in the thoracic region. The effects of the changed acquisition parameters on the image quality are evaluated using the Catphan Phantom and the image analysis software Smári. The weighted CT dose index (CTDIW) is determined in each case and the effects of the different acquisition protocols on the patient dose are classified accordingly. Additionally, the clinical suitability of alternative presets is tested by investigating correctness of image registration using the CIRS thorax phantom. The results show that a significant dose reduction can be achieved. It can be reduced by 51% for a full rotation by adjusting the gantry speed.
Background: By reviewing image quality and diagnostic perception, the suitability of a statistical model-based iterative reconstruction algorithm in conjunction with low-dose computed tomography for lung cancer screening is investigated.
Methods: Artificial lung nodules shaped as spheres and spiculated spheres made from material with calibrated Hounsfield units were attached on marked positions in the lung structure of anthropomorphic phantoms. The phantoms were scanned using standard high contrast, and two low-dose computed tomography protocols: low-dose and ultra-low-dose. For the reconstruction, the filtered back projection and the iterative reconstruction algorithm ADMIRE at different strength levels (S1–S5) and the kernels Bl57, Br32, Br69 were used. Expert radiologists assessed image quality by performing 4-field-ranking tests and reading all image series to examine the aptitude for the detectability of lung nodules. Signal-to-noise ratio was investigated as objective image quality parameter.
Results: In ranking tests for lung foci detection expert radiologists prefer medium to high iterative reconstruction strength levels. For the standard clinical kernel Bl57 and varying phantom diameter, a noticeable preference for S4 was detected. Experienced radiologists graded filtered back projection reconstructed images with the highest perceptibility. Less experienced readers assessed filtered back projection and iterative reconstruction equally with the highest grades for the Bl57 kernel. Independently of the dose protocol, the signal-to-noise ratio increases with the iterative reconstruction strength level, specifically for Br69 and Bl57.
Conclusions: Subjective image perception does not significantly correlate with the experience of the radiologist, which presumably mirrors reader’s training and accustomed reading adjustments. Regarding signal-to-noise ratio, iterative reconstruction outperforms filtered back projection for spheres and spiculated spheres. Iterative reconstruction matters. It promises to be an alternative to filtered back projection allowing for lung-cancer screening at markedly decreased radiation exposure but comparable or even improved image quality.
Cardiac and liver computed tomography (CT) perfusion has not been routinely implemented in the clinic and requires high radiation doses. The purpose of this study is to examine the radiation exposure and technical settings for cardiac and liver CT perfusion scans at different CT scanners. Two cardiac and three liver CT perfusion protocols were examined with the N1 LUNGMAN phantom at three multi-slice CT scanners: a single-source (I) and second- (II) and third-generation (III) dual-source CT scanners. Radiation doses were reported for the CT dose index (CTDIvol) and dose–length product (DLP) and a standardised DLP (DLP10cm) for cardiac and liver perfusion. The effective dose (ED10cm) for a standardised scan length of 10 cm was estimated using conversion factors based on the International Commission on Radiological Protection (ICRP) 110 phantoms and tissue-weighting factors from ICRP 103. The proposed total lifetime attributable risk of developing cancer was determined as a function of organ, age and sex for adults. Radiation exposure for CTDIvol, DLP/DLP10 cm and ED10 cm during CT perfusion was distributed as follows: for cardiac perfusion (II) 144 mGy, 1036 mGy·cm/1440 mGy·cm and 39 mSv, and (III) 28 mGy, 295 mGy·cm/279 mGy·cm and 8 mSv; for liver perfusion (I) 225 mGy, 3360 mGy·cm/2249 mGy·cm and 54 mSv, (II) 94 mGy, 1451 mGy·cm/937 mGy·cm and 22 mSv, and (III) 74 mGy, 1096 mGy·cm/739 mGy·cm and 18 mSv. The third-generation dual-source CT scanner applied the lowest doses. Proposed total lifetime attributable risk increased with decreasing age. Even though CT perfusion is a high-dose examination, we observed that new-generation CT scanners could achieve lower doses. There is a strong impact of organ, age and sex on lifetime attributable risk. Further investigations of the feasibility of these perfusion scans are required for clinical implementation.
The aim of this phantom study is to examine radiation doses of dual- and single-energy computed tomography (DECT and SECT) in the chest and upper abdomen for three different multi-slice CT scanners. A total of 34 CT protocols were examined with the phantom N1 LUNGMAN. Four different CT examination types of different anatomic regions were performed both in single- and dual-energy technique: chest, aorta, pulmonary arteries for suspected pulmonary embolism and liver. Radiation doses were examined for the CT dose index CTDIvol and dose-length product (DLP). Radiation doses of DECT were significantly higher than doses for SECT. In terms of CTDIvol, radiation doses were 1.1–3.2 times higher, and in terms of DLP, these were 1.1–3.8 times higher for DECT compared with SECT. The third-generation dual-source CT applied the lowest dose in 7 of 15 different examination types of different anatomic regions.
A qualitative work‐flow analysis of a neurosurgical procedure indicates that the resolution of the image used to plan the intervention is the major source of inaccuracy. Quantitative experimental measurements confirm this observation. They fail, however, to explain the relationship between the accuracy of the frame components involved in a stereotactic procedure and the overall application accuracy. This investigation shows that the novel Gaussian approach is a flexible framework for the calculation of the application accuracy of frame systems. Therefore, the Gaussian approach provides a detailed understanding of the interplay between the various factors affecting accuracy. The basic ideas and limitations of the Gaussian approach are briefly explained. The effect of fiducial marker distribution and registration is investigated and shown to introduce a spatial dependence to the accuracy. The results of the Gaussian approach are compared with experimental data for three stereotactic frame devices: Leksell G, Cosman–Roberts–Wells, and Brown–Roberts–Wells. Although the Gaussian approach is an approximation, it reproduces the accuracy measured in the experiment within the statistical error of that experiment. Comp Aid Surg 4:77–86 (1999). © 1999 Wiley‐Liss, Inc.
Stereotactic frame systems are widely used in neurosurgery. The accuracy of frame devices is considered as a gold standard to which the accuracy of new frameless stereotactic navigation systems is compared. The purpose of this study is to develop a general approach for the prediction of the application accuracy of stereotactic systems. The approach will be applied to the frame‐based biopsy performed with three frame devices: Leksell G, Cosman–Roberts–Wells (CRW), and Brown–Roberts–Wells (BRW). A work‐flow analysis will be carried out demonstrating that the accuracy relevant for a clinical application comprises several error sources including imaging, target and entry point selection, image to frame coordinates registration, and the setting of mechanical parameters of the frame. These error sources will be postulated to obey a Gaussian distribution probability density. The linear, i.e., Gaussian, error propagation, will be used to link all error contributions thus to calculate the cumulative accuracy of the frame used in the application. Although the Gaussian approach is an approximation, it allows for an analytical treatment of the accuracy. Both the accuracy at the target point and the accuracy of the probe needle guidance along the planned trajectory have been investigated. Of great significance is the relationship found between accuracy, pixel dimension, and image slice thickness, the latter being the dominant factor for slices of more than 1.5 mm thickness, yielding inaccuracies larger than 1.5 mm. For target points the predictions for the application accuracy have been compared to the results of measurements, showing good agreement with the experimental data.
Three-dimensional magnetic resonance medical images may contain scanner- and patient-induced geometric distortion. For qualitative diagnosis, geometric errors of a few millimeters are often tolerated. However, quantitative applications such as image-guided neurosurgery and radiotherapy can require an accuracy of a millimeter or better. We have developed a method to accurately measure scanner-induced geometric distortion and to correct the MR images for this type of distortion. The method involves a number of steps. First, a specially designed phantom is scanned that contains a large number of reference structures on positions with a manufacturing error of less than 0.05 mm. Next, the positions of the reference structures are automatically detected in the scanned images and a higher-order polynomial distortion-correction transformation is estimated. Then the patient is scanned and the transformation is applied to correct the patient images for the detected distortion. The distortion-correction method is explained in detail in this paper. The accuracy of the method has been measured with synthetically generated phantom scans that contain an exactly-known amount and type of distortion. The reproducibility of the method has been measured by applying it to a series of consecutive phantom scans. Validation results are briefly described in this paper, a more-detailed description is given in another submission to SPIE Medical Imaging 2001.