Filtern
Erscheinungsjahr
Dokumenttyp
Schlagworte
- API 1130 (1)
- CPM (1)
- Deutschland / Technische Regeln für brennbare Flüssigkeiten (1)
- Elektrodenvorbereitung (1)
- Fehlererkennung (1)
- Fehlerortung (1)
- Implantat (1)
- Kernspintomografie (1)
- Kohlenstoff (1)
- Leak detection (1)
- Leckerkennung (1)
- Leckortung (1)
- Lecksuchgerät (1)
- Lecküberwachung (1)
- Nanofaser (1)
- PEM fuel cells (1)
- PEM-Brennstoffzelle (1)
- Polymer-Elektrolytmembran-Brennstoffzelle (1)
- Regeln der Technik (1)
- Sauerstoffplasmaaktivierung (1)
- Spondylodese (1)
- TRFL (1)
- carbon nano fibres (1)
- electrode preparation (1)
- leak locating (1)
- leak monitoring (1)
- oxygen plasma activation (1)
Institut
- Elektrotechnik und angewandte Naturwissenschaften (59) (entfernen)
The purpose of this work was to develop and investigate a radiofrequency (RF) coil to perform image studies on small animals using the 7T magnetic resonance imaging (MRI) system, installed in the imaging platform in the autopsy room (Portuguese acronym PISA), at the University of Sao Paulo, Brazil, which is the unique 7T MRI scanner installed in South America. Due to a high demand to create new specific coils for this 7T system, it is necessary to carefully assess the distribution of electromagnetic (EM) fields generated by the coils and evaluate the patient/object safety during MRI procedures. To achieve this goal 3D numerical methods were used to design and analyse a 8-rungs transmit/receive linearly driven birdcage coil for small animals. Calculated magnetic field (B 1) distributions generated by the coil were crosschecked with measured results, indicating good confidence in the simulated results.
Many fluids transported by pipelines are in some sense hazardous. It is therefore often necessary to install leak detection (and locating) systems (LDS), especially due to legal regulations like the "Code for Federal Regulations (CFR) Title 49 Part 195", API 1130 2nd Ed., both for the USA, or the "Technische Regeln für Fernleitungen" (TRFL) (Technical Rules for Pipelines) in Germany. This paper gives a survey of methodologies, methods and techniques for leak detection and locating. The survey starts with some remarks concerning (legal) regulations both for the USA and for Germany. Some few words about externally based systems (due to API 1130 2nd Ed.) follow next. A significant part of the paper deals with internally based systems (also due to API 1130 2nd Ed.) like balancing systems (line balance, volume balance, compensated mass balance etc.), Real Time Transient Model LDS (RTTM-LDS), pressure/flow monitoring and statistical analysis LDS. Different methods for leak locating (gradient intersection method, wave propagation analysis etc.) will also be shown. The presentation of an Extended RTTM approach (E-RTTM) combining advantages of conventional RTTM LDS and statistical analysis follows next, together with the demonstration of applicability by means of two examples, a liquid multi-batch pipeline, and a gas pipeline. Sketching future work and the conclusion conclude the survey.
Cone-Beam computed tomography (CBCT) has become the most important component of modern radiotherapy for positioning tumor patients directly before treatment. In this work we investigate alternations to standard acquisition protocol, called preset, for patients with a tumor in the thoracic region. The effects of the changed acquisition parameters on the image quality are evaluated using the Catphan Phantom and the image analysis software Smári. The weighted CT dose index (CTDIW) is determined in each case and the effects of the different acquisition protocols on the patient dose are classified accordingly. Additionally, the clinical suitability of alternative presets is tested by investigating correctness of image registration using the CIRS thorax phantom. The results show that a significant dose reduction can be achieved. It can be reduced by 51% for a full rotation by adjusting the gantry speed.
Metallic implants in magnetic resonance imaging (MRI) are a potential safety risk since the energy absorption may increase temperature of the surrounding tissue. The temperature rise is highly dependent on implant size. Numerical examinations can be used to calculate the energy absorption in terms of the specific absorption rate (SAR) induced by MRI on orthopaedic implants. This research presents the impact of titanium osteosynthesis spine implants, called spondylodesis, deduced by numerical examinations of energy absorption in simplified spondylodesis models placed in 1.5 T and 3.0 T MRI body coils. The implants are modelled along with a spine model consisting of vertebrae and disci intervertebrales thus extending previous investigations [1], [2]. Increased SAR values are observed at the ends of long implants, while at the center SAR is significantly lower. Sufficiently short implants show increased SAR along the complete length of the implant. A careful data analysis reveals that the particular anatomy, i.e. vertebrae and disci intervertebrales, has a significant effect on SAR. On top of SAR profile due to the implant length, considerable SAR variations at small scale are observed, e.g. SAR values at vertebra are higher than at disc positions.
Metallic implants in magnetic resonance imaging (MRI) are a potential safety risk since the energy absorption may increase temperature of the surrounding tissue. The temperature rise is highly dependent on implant size. Numerical examinations can be used to calculate the energy absorption in terms of the specific absorption rate (SAR) induced by MRI on orthopaedic implants. This research presents the impact of titanium osteosynthesis spine implants, called spondylodesis, deduced by numerical examinations of energy absorption in simplified spondylodesis models placed in 1.5 T and 3.0 T MRI body coils. The implants are modelled along with a spine model consisting of vertebrae and disci intervertebrales thus extending previous investigations [1, 2]. Increased SARvalues are observed at the ends of long implants, while at the center SAR is significantly lower. Sufficiently short implants show increased SAR along the complete length of the implant. A careful data analysis reveals that the particular anatomy, i.e. vertebrae and disci intervertebrales, has a significant effect on SAR. On top of SAR profile due to the implant length, considerable SAR variations at small scale are observed, e.g. SAR values at vertebra are higher than at disc positions.
A simplified model for spondylodesis, ie fixation of vertebrae by osteosynthesis, is developed for virtual magnetic resonance imaging (MRI) examinations to numerically calculate energy absorption. This paper presents results of calculated energy absorption in body tissue surrounding titanium rod implants. In general each wire or rod behaves like an antenna in electromagnetic fields. The specific absorption rate (SAR) profile describes dependence of implant size. SAR hotspots appear near the rod edges. Depending of the size of implant fixation SAR is 62%(small fixation) up to 90.95%(large fixation) higher than without implants. In addition, local SAR profile displays local dependency on tissue: SAR is lower between the vertebrae.
Telemetrie
(2008)
Protraction Effects in a Stochastic Cell-Cycle Tumor Model Exposed to Fractionated Radiotherapy
(2013)
In this research computer tomography (CT) iterative reconstruction (IR) algorithms are investigated, specifically the impact of their statistical and model-based strength on image quality in low-dose lung screening CT protocols in comparison to filtered back projection (FBP). It has been probed whether statistical, model-based IR in conjunction with low-dose, and ultra-low-dose protocols are suitable for lungcancer screening. To this end, artificial lung nodules shaped as spheres and spicules made from material with calibrated Hounsfield units (HU) were attached on marked positions in the lung structure of an anthropomorphic phantom. Nodule positions were selected by distinguished radiologists. The phantom with nodules was scanned on a CT Scanner using standard high contrast (SHC), low-dose (LD) and ultra low-dose (ULD) protocol. For reconstruction FBP and the IR algorithm ADMIRE at three different …