Filtern
Dokumenttyp
Schlagworte
- Building Information Modeling (5)
- Kühllastberechnung (4)
- Klimaänderung (3)
- Qualitätsplan (3)
- Reinraumtechnik (3)
- VDI 2078 (3)
- BIM (2)
- Deutschlandwetter (2)
- IFC (2)
- Industry Foundation Classes (2)
- Klimatechnik (2)
- Klimawandel (2)
- Aerosol (1)
- Air handling unit (1)
- BIM Weiterbildung (1)
- Climate change (1)
- Datenmanagement (1)
- Energieeffizienz (1)
- Future capacity needs (1)
- Gesellschaft Technische Gebäudeausrüstung (1)
- Haustechnik (1)
- Hygiene (1)
- Lehre (1)
- Leistungsreserve (1)
- Lüftungsanlage (1)
- Mund-Nasen-Schutz (1)
- Nachhaltigkeit, GEG, intelligente Gebäude (1)
- Praxis (1)
- RLT-Auslegung (1)
- RLT-Geräte (1)
- RLT-Geräte, Klimawandel, Leistungsreserve (1)
- Raumluft (1)
- Raumluftreiniger (1)
- Raumluftströmung (1)
- Raumlufttechnisches Gerät (1)
- SARS-CoV-2 (1)
- Skalierung (1)
- TGA (1)
- TGA-Büro (1)
- Technische Gebäudeausrüstung (1)
- Urban heat island (1)
- Wärmepumpen, VDI 4645, Jahresarbeitszahl, Wärmewende, Bewertungstool (1)
- aerosol (1)
- air hygiene (1)
- airborne infection (1)
- face mask (1)
- mobile Luftreiniger (1)
- ventilation (1)
- Ähnlichkeitstheorie (1)
Institut
Building Information Modeling (BIM) wird im Bauwesen immer stärker gefordert. Der vorliegende Artikel befasst sich mit dem Datenaustausch für die TGA. Am Beispiel eines RLT-Gerätes werden der Detaillierungsgrad und der Datenaufbau mit IFC erläutert. Insbesondere zeigt sich hierbei, dass der Datenimport aufgrund fehlender Standards und Definitionen mit Datenverlust einhergeht. Damit ergibt sich ein Auftrag an die Softwareunternehmen hier für eindeutige Standards zu sorgen.
TGA-Planung mit BIM-Objekten
(2019)
Die BIM-Methode erfasst in Deutschland mittlerweile alle Gewerke im Bauhauptgewerbe. Für die TGA-Branche hat sich gezeigt, dass die Priorität der Produkthersteller auf der Bereitstellung der Geometriedaten liegt. Weiterführende Metadaten und Attribute (z. B. Material, Masse, Preise, Leistungsdaten) sind oftmals nur in reduzierter Form oder gar nicht vorhanden. An exemplarischen Beispielen von RLT-Reräten und Komponenten werden die geometrischen und semantischen Möglichkeiten beim IFC-Format untersucht.
TGA-Modelle in BIM-Projekten
(2020)
Die BIM-Methode erfasst in Deutschland mittlerweile alle Gewerke im Bauhauptgewerbe. Für die TGA-Branche hat sich gezeigt, dass die Priorität der Produkthersteller auf der Bereitstellung der Geometriedaten liegt. Weiterführende Metadaten und Attribute (z. B. Material, Masse, Preise, Leistungsdaten) sind oftmals nur in reduzierter Form oder gar nicht vorhanden. An exemplarischen Beispielen von RLT-Reräten und Komponenten werden die geometrischen und semantischen Möglichkeiten beim IFC-Format untersucht.
Gebäude sind immer auch ein Ausdruck der Zeit, in der sie erbaut wurden. Oft bleiben sie sehr lange erhalten und erfahren über die Jahrzehnte mehrfache Nutzungsänderungen. Betroffen sind alte Produktionshallen ebenso wie Verwaltungsimmobilien. Die Gebäudehülle bleibt bei einer Umnutzung meist unangetastet. Aufgabe der Technischen Gebäudeausrüstung ist es dann, das Raumklima für die Nutzer unter den geänderten Bedingungen behaglich zu gestalten und die Aspekte der Energieeffizienz und Nachhaltigkeit nicht aus den Augen zu verlieren. Insbesondere die Kühlung der Gebäude im Sommer steht aufgrund der steigenden internen Lasten und der solaren Gewinne durch große Glasfassaden im Vordergrund.
Am Beispiel eines rund 100 Jahre alten Verwaltungsgebäudes wird gezeigt, wie eine dynamischen Kühllastberechnung eine exakte Voraussage der zu erwartenden Spitzenlasten ermöglicht. Darauf basierend kann dann eine individuelle RLT-Anlagentechnik installiert wird. Die Auslegung erfolgt mit zwei Versionen der VDI 2078. Die Ergebnisse werden miteinander verglichen.
Die Planung und der Bau von Reinräumen sind komplexe Vorgänge, die ein hohes Maß an logistischer und fachlicher Kompetenz erfordern. Insbesondere ist die stetige Steigerung der Reinheit bis zur Inbetriebnahme eine wesentliche Voraussetzung für den späteren bestimmungsgemäßen Betrieb. Die Regelwerke und hier insbesondere die VDI 2083 liefert klare Vorgaben für den Planungsablauf. Um die Umsetzung der Richtlinie in die Praxis jedoch einfacher und unmissverständlich zu gestalten, sollte ein dezidierter Qualitätsplan vor jedem Projektbeginn ausgearbeitet werden. Dieser soll in Abhängigkeit des Baufortschritts die Bau- und Schutzmaßnahmen koordinieren und klare Regeln für die am Bau Beteiligten festlegen. Um unvorhergesehene Fehler und deren Folgen zu minimieren bietet sich die Fehlermöglichkeits- und Einflussanalyse (FMEA) als Bestandteil des Qualitätsplans an. Hierdurch werden mögliche Fehler beschrieben und die Risiken erfasst und vorsorglich minimiert. Die Risikoprioritätszahl (RPZ) ist dabei ein Maß für den möglichen Schaden. Die FMEA sorgt dafür, dass die festgelegten Maßnahmen mit hoher Wirksamkeit umgesetzt werden können.
Die Erstellung der FMEA betrifft alle Gewerke beim Bau des Reinraums, daher sollten die Inhalte in gemeinsamen Besprechungen aller Verantwortlichen für jedes Bauvorhaben individuell erstellt werden. Dadurch ist zusätzlich das Bewusstsein zur Reinhaltung bei allen Gewerken gegeben. Der Bauleitung obliegt die durchgehende und verantwortungsbewusste Umsetzung des Qualitätsplans.
Zur Planung und zum Bau von Reinräumen gibt es zwei Normen (VDI 2083 „Reinraumtechnik“ und ISO 14644 „Reinräume und zugehörige Reinraumbereiche“). Beide Normen fordern einen Qualitätsplan, der aber nicht eindeutig definiert ist. In der Praxis bedeutet dies, dass sich die ausführenden Planer und Gewerke nicht auf eine allgemein gültige Norm für einen Qualitätsplan verlassen können. Genau an dieser Stelle setzt eine Masterarbeit an und definiert einen möglichen Qualitätsplan mit Zwischenzielen und den dafür erforderlichen Maßnahmen. Unter anderem wird zur Sicherstellung der einzelnen Baufortschritte und zur Einhaltung des Reinraumkonzepts die Methodik der Fehlermöglichkeits- und Einflussanalyse (FMEA) eingeführt. Diese Methodik wird bereits in der Automobilindustrie angewendet und umfasst unter anderem auch die sogenannte Risikoprioritätszahl (RPZ), die das Gesamtrisiko eines möglichen Fehlers in Planung und Bau beziffert. cci Zeitung hat bei Prof. Christian Fieberg, seit März 2017 Professor für Gebäudetechnik, und M. Sc. Lea Klaßen, Verfasserin der Masterarbeit, beide Westfälische Hochschule Gelsenkirchen, zu diesem Thema nachgefragt.
Der zuverlässige und sichere Betrieb eines Reinraums hängt maßgeblich von der Planung ab.
DIN EN ISO 14644, Teil 4, und VDI 2083, Blatt 4 legen zahlreiche Vorgaben zur Planung, Ausführung und Erst-Inbetriebnahme fest. Der „rote Faden“ ist dabei der Qualitätsplan. Dieser soll sicherstellen, dass bei der Planung und dem Bau des Reinraums die nachfolgende Qualifizierung erfolgreich durchgeführt werden kann. Die Vorgaben hierzu sind in den beiden Regelwerken allerdings unzusammenhängend und bei der praktischen Umsetzung und Abstimmung der einzelnen Gewerke meist nicht ausreichend.
Aufgrund der Energiewende und den steigenden Anforderungen an die technische Gebäudeausrüstung gewinnt der Betrieb von Wärmepumpen in Gebäuden immer mehr an Bedeutung. Inzwischen existiert eine Vielzahl an Wärmepumpen-Systemen, die unterschiedliche Vor- und Nachteile sowie Einsatzmöglichkeiten aufweisen. Sofern die Installation einer Wärmepumpe für den Wohngebäudesektor in Betracht gezogen wird, muss eruiert werden, welches System sowohl ökologisch als auch ökonomisch für das Bauvorhaben am sinnvollsten ist. Hierfür wurde eine Bewertungstool entwickelt, das den Einsatz der unterschiedlichen Wärmepumpensysteme bewertet und auch Nutzern mit wenig Expertise eine Entscheidungshilfe ermöglicht. Für eine möglichst ganzheitliche Betrachtung können verschiedene Szenarien mit Hilfe des Bewertungstools überprüft werden. Hierzu können Indikatoren wie Standortdaten, Gebäudedaten, Parameter für die Trinkwassererwärmung, die Systemtemperaturen der Heizung und die Betriebsweise der Wärmepumpe im Tool variiert werden. Die Ergebnisse des Bewertungstools zeigen, wie die unterschiedlichen Nutzungsanforderungen sich auf die Jahresarbeitszahl und den Energiebedarf auswirken. Zusätzlich werden Investitions- und Verbrauchskosten für die unterschiedlichen Szenarien abgeschätzt und berechnet. Bei der ökologischen Bewertung wird der Fokus der Betrachtung auf den TEWI-Wert gelegt, um den Einfluss von verschiedener Kältemittel im Lebenszyklus der Wärmepumpe zu berücksichtigen.
As vaccination campaigns are in progress in most countries, hopes to win back more normality are rising. However, the exact path from a pandemic to an endemic virus remains uncertain. While in the pre-vaccination phase many critical indoor situations were avoided by strict control measures, for the transition phase a certain mitigation of the effect of indoor situations seems advisable.
To better understand the mechanisms of indoor airborne transmissions, we present a new time-discrete model to calculate the level of exposure towards infectious SARS-CoV-2 aerosol and carry out a sensitivity analysis for the level of SARS-CoV-2 aerosol exposure in indoor settings. Time limitations and the use of any kind of masks were found to be strong mitigation measures, while how far the effort for a strict use of professional face pieces instead of simple masks can be justified by the additional reduction of the exposure dose remains unclear. Very good ventilation of indoor spaces is mandatory. The definition of sufficient ventilation in regard to airborne SARS-CoV-2 transmission follows other rules than the standards in ventilation design. This means that especially smaller rooms most likely require a significantly greater fresh air supply than usual. Further research on 50% group models in schools is suggested. The benefits of a model in which the students come to school every day, but for a limited time, should be investigated. In terms of window ventilation, it has been found that many short opening periods are not only thermally beneficial, they also reduce the exposure dose. The fresh air supply is driven by the temperature gradient and wind speed. However, the sensitivity towards these parameters is not very high and in times of low wind and temperature gradients, there are no arguments against keep windows open in order to make up for the reduced air flow rate. Long total opening periods and large window surfaces will strongly reduce the exposure. Additionally, the results underline the expectable fact that exposure doses will increase when hygiene and control measures are reduced. It seems advisable to investigate what this means for the infection rate and the fatality of infections in populations with partial immunity. Very basic considerations suggest that the value of aerosol reduction measures may be reduced with very infectious variants such as delta.
Im zweiten Corona-Winter sollen die Schulen offenbleiben. Neben Fenster- und mechanischer Lüftung werden mobile Raumluftreiniger als sinnvolle Maßnahmen angesehen, um das Infektionsrisiko zu reduzieren. Dabei stellt sich die Frage, wie deren sicherer und zuverlässiger Betrieb gestalten sein muss. Gibt es bevorzugte Aufstellpositionen im Raum und wie wirkt sich die Luftbewegung auf die Behaglichkeit aus? Die Datenlage hierzu ist noch unzureichend (vgl. HLH-Interview mit Dr. Gommel, HLH 10/2021). Diese Fragen werden für einen typischen Seminar- und Klassenraum näher beleuchtet.
Am Beispiel eines rund 100 Jahre alten Verwaltungsgebäudes wird gezeigt, wie eine dynamische Kühllastberechnung eine exakte Voraussage der zu erwartenden Spitzenlasten ermöglicht. Darauf basierend kann dann eine individuelle RLT-Anlagentechnik installiert werden. Die Auslegung erfolgt mit zwei Versionen der VDI 2078. Die Ergebnisse werden miteinander verglichen.
Die Neuberechnung der Kühllast von Gebäuden im Bestand wird immer dann nötig, wenn sich größere Nutzungsänderungen ergeben. Dabei ist die Datenlagen zur Bausubstanz und dem Aufbau der Umschließungsflächen meist unzureichend für die Eingabe in die Berechnungsalgorithmen nach VDI 2078:2015-06. Der Artikel analysiert an einem denkmalgeschützten Verwaltungsgebäude die wichtigsten Einflussfaktoren auf die Kühllast. Dabei wir auch ein Vergleich zur lange gültigen Vorgängerrichtline von 1996 durchgeführt.
Nachhaltigkeit von intelligenten Gebäuden - Ein Blick auf die Gesetzgebungen und Praxismöglichkeiten
(2023)
Gebäude sind durch ihre Herstellung und den Betrieb für einen erheblichen Teil der CO2-Emissionen in Europa verantwortlich. Die EU und Deutschland wollen durch milliardenschwere Maßnahmenpakete diese Emissionen bis zum Jahr 2045 (Deutschland) bzw. 2050 (EU) auf null reduzieren. Neben der Gebäudehülle als maßgeblicher Faktor für die Wärmebilanz zum Heizen und Kühlen spielt die Gebäudeautomation eine wichtige Rolle. Wie Gebäude intelligenter und smarter werden und wie sich das auf die Energieeffizienz auswirkt, soll im Folgenden betrachtet werden.
RLT-Geräte werden meist auf eine Lebensdauer von 15 Jahren ausgelegt. Die Erfahrung zeigt jedoch, dass viele Anlagen mehr oder weniger unverändert bis zu 25 Jahren betrieben werden. Damit müssen aktuell projektierte RLT-Anlagen auch bei dem erwarteten Klimawandel die gewünschten Zuluftparameter (Temperatur und Luftfeuchte) einhalten. Der Artikel untersjucht den einfluss des Klimawandels für Deutschland bezogen auf die Klimatisierung einer exemplarischen Krankenhausintensivstation.
Der prognostizierte Klimawandel erfordert bereits für die heutige Auslegung von RLT-Geräten eine Berücksichtigung der zukünftigen Wetterdaten in Form von Testreferenzjahren(TRY). Am Beispiel einer Intensivstation eines Krankenhauses werden für alle 15 Klimaregionen in Deutschland die Unterschiede der Heiz- & Kühlleistung sowie der Betriebsstunden analysiert.
Air Handling units (AHU) are designed to guarantee a high indoor air quality for any time and outdoor condition all over the year. To do so, the AHU removes particle matter like dust or pollen and adapts the thermophysical properties of air to the desired, seasonal indoor comfort conditions. AHU have a robust design and thus operate for more than fifteen years, sometimes even for decades. An AHU designed today must consider and anticipate the change of user needs as well as outdoor air conditions for the next twenty years. To anticipate the outdoor air condition of coming decades, scientific models exist, which allow the design of peak performance and capacities of the air treatment components. It is most likely, that the ongoing climate change will lead to higher temperatures as well as higher humidity, while the comfort zone of human beings will remain at today’s values. Next to the impact of global warming with average rise of mean air temperature local effects will influence the operation of AHU. On effect investigated here is the steep temperature increase in city centres called urban heat islands. Heating and cooling capacities as well as water consumption for humidification are investigated for a reference AHU for fifteen regional locations in Germany. These regions represent all climate zones within the country. Additionally, the urban heat island effect was investigated for Berlin Alexanderplatz compared a rural area close by. The AHU was chosen to operate in an intensive care unit of a hospital. The set-up leads to 24/7 operation with 8760 hours per year. The article presents the modelling of current and future weather data as well as the unit set up. The calculated hourly performance and capacity parameters for current (reference year 2012) and future weather data (reference year 2045) yield energy consumption and peak loads of the unit for heating, cooling and humidification. The results are displayed by relative comparisons of each performance value.
Die Klimatisierung von Gebäuden gewinnt zunehmend an Bedeutung. Dies liegt zum einen an der Bauweise und Nutzung, die höhere Kühllasten mit sich bringt. Zum anderen fordern die Nutzer eine angemessene Behaglichkeit bei hoher Luftqualität.
Diese Forderungen gehen einher mit hoher Energieeffizienz und einwandfreier Hygiene der Raum-lufttechnischen Anlagen. Dieser Beitrag untersucht diese Forderungen für Nichtwohngebäude und prüft, ob Hygiene und Energieeffizienz zu Zielkonflikten führen können.
Der Mensch verbringt einen Großteil seiner Zeit in geschlossenen Räumen und erwartet, dass die Luftqualität mindestens der Außenluft entspricht. Mit Blick auf die aktuelle Feinstaubdebatte, muss die Raumluftqualität noch deutlich darüber hinaus gehen. Weiterhin soll der Aufenthalt am Arbeitsplatz nicht zu gesundheitlichen Beeinträchtigungen führen (Reizung der Schleimhäute, trockene Augen oder virale Infektionen).
Die Klimatisierung von Gebäuden benötigt einen nicht unerheblichen Teil der Primärenergie, so dass ein effizienter Anlagenbetrieb ein wichtiger Baustein der Energiewende ist. Dabei spielt die Nutzung von regenerativen Energien (Solarstrom zur Gebäudekühlung) genauso eine wichtige Rolle wie die Optimierung von Komponenten und deren Abstimmung zum „System Gebäudeklimatisierung“.
Zur Einordnung der Themengebiete werden die relevanten Normen und Regelwerke auf europäischer und deutscher Ebene kurz vorgestellt und erläutert.
Am Beispiel eines typischen RLT-Gerätes werden die Komponenten und Funktionen im Betrieb veranschaulicht. Die wichtigsten Komponenten (z. B. Filter, Wärmeübertrager, Befeuchter und Ventilatoren) werden mit Blick auf Hygiene und Energieeffizienz anschließend analysiert und verglichen. Die Vergleiche finden anhand von Fallbeispielen statt, wie sie für Nichtwohngebäude typisch sind. Zusammenfassend wird die Ausgangsfrage aus Sicht des Autors beantwortet.
Building Information Modeling, kurz BIM, wird als revolutionäre Methode gepriesen, die der Baubranche helfen soll, effizienter und kostengünstiger zu bauen. Gerne wird hierbei der Vergleich mit der Einführung von CAD-Systemen in den 1990er Jahren herangezogen, der jedoch zu kurz greift. BIM ist vielmehr als der Wechsel vom Tuschestift hin zur Computermaus. Dieser Beitrag gibt einen kurzen Einblick in das Thema BIM und den heutigen Stand in Deutschland. Hierbei soll insbesondere die Sicht der Bauherren und Betreiber berücksichtigt werden, da diese in den meisten Betrachtungen nur oberflächlich gesteift werden.