Filtern
Erscheinungsjahr
Dokumenttyp
- Wissenschaftlicher Artikel (210)
- Konferenzveröffentlichung (210)
- Teil eines Buches (Kapitel) (31)
- Sonstiges (29)
- Video (14)
- Buch (Monographie) (13)
- Preprint (9)
- Dissertation (4)
- Arbeitspapier (4)
- Bericht (3)
Sprache
- Englisch (532) (entfernen)
Schlagworte
- Robotik (8)
- Flugkörper (7)
- UAV (7)
- Rettungsrobotik (5)
- Polymer-Elektrolytmembran-Brennstoffzelle (4)
- adhesion (4)
- Bionik (3)
- Erweiterte Realität <Informatik> (3)
- Gespenstschrecken (3)
- Haftorgan (3)
Institut
- Westfälisches Institut für Gesundheit (115)
- Institut für Internetsicherheit (56)
- Informatik und Kommunikation (51)
- Elektrotechnik und angewandte Naturwissenschaften (50)
- Wirtschaft und Informationstechnik Bocholt (46)
- Westfälisches Energieinstitut (42)
- Institut für biologische und chemische Informatik (37)
- Maschinenbau Bocholt (37)
- Institut Arbeit und Technik (15)
- Wirtschaftsingenieurwesen (15)
Metallic implants in magnetic resonance imaging (MRI) are a potential safety risk since the energy absorption may increase temperature of the surrounding tissue. The temperature rise is highly dependent on implant size. Numerical examinations can be used to calculate the energy absorption in terms of the specific absorption rate (SAR) induced by MRI on orthopaedic implants. This research presents the impact of titanium osteosynthesis spine implants, called spondylodesis, deduced by numerical examinations of energy absorption in simplified spondylodesis models placed in 1.5 T and 3.0 T MRI body coils. The implants are modelled along with a spine model consisting of vertebrae and disci intervertebrales thus extending previous investigations [1, 2]. Increased SARvalues are observed at the ends of long implants, while at the center SAR is significantly lower. Sufficiently short implants show increased SAR along the complete length of the implant. A careful data analysis reveals that the particular anatomy, i.e. vertebrae and disci intervertebrales, has a significant effect on SAR. On top of SAR profile due to the implant length, considerable SAR variations at small scale are observed, e.g. SAR values at vertebra are higher than at disc positions.
This book provides unique insights into how the idea of quota laws to get women on to corporate boards gained international momentum from its origins in Norway. Invaluable insights are gained through the stories of actors involved in shaping the discourse and practice on women of boards.
In exploring political contexts, the role of the advocacy movement, experiences of women directors themselves and latest research findings, the contributors provide a comprehensive overview of the rationales, processes and outcomes of formal approaches to gender diversity on boards. Drawing on insights from political, business and academic actors, the book discusses how and why the Norwegian law on gender equality on corporate boards is turning into a blueprint for action internationally.
Getting Women on to Corporate Boards will prove an invaluable resource for policy-makers, principle-setters, practitioners and students interested in the international lessons from Norway, as well as for current and potential female directors.
The translation of images of chemical structures into machine-readable representations of the depicted molecules is known as optical chemical structure recognition (OCSR). There has been a lot of progress over the last three decades in this field, but the development of systems for the recognition of complex hand-drawn structure depictions is still at the beginning. Currently, there is no data for the systematic evaluation of OCSR methods on hand-drawn structures available. Here we present DECIMER - Hand-drawn molecule images, a standardised, openly available benchmark dataset of 5088 hand-drawn depictions of diversely picked chemical structures. Every structure depiction in the dataset is mapped to a machine-readable representation of the underlying molecule. The dataset is openly available and published under the CC-BY 4.0 licence which applies very few limitations. We hope that it will contribute to the further development of the field.
The concept of molecular scaffolds as defining core structures of organic molecules is utilised in many areas of chemistry and cheminformatics, e.g. drug design, chemical classification, or the analysis of high-throughput screening data. Here, we present Scaffold Generator, a comprehensive open library for the generation, handling, and display of molecular scaffolds, scaffold trees and networks. The new library is based on the Chemistry Development Kit (CDK) and highly customisable through multiple settings, e.g. five different structural framework definitions are available. For display of scaffold hierarchies, the open GraphStream Java library is utilised. Performance snapshots with natural products (NP) from the COCONUT database and drug molecules from DrugBank are reported. The generation of a scaffold network from more than 450,000 NP can be achieved within a single day.
Analysis of future development opportunities for OIS (Office Information Systems) methods and tools.
(1992)
Segmentation of radio-angiographic images using morphological filters, thinning and region growing
(1997)
Stereotactic frame systems are widely used in neurosurgery. The accuracy of frame devices is considered as a gold standard to which the accuracy of new frameless stereotactic navigation systems is compared. The purpose of this study is to develop a general approach for the prediction of the application accuracy of stereotactic systems. The approach will be applied to the frame‐based biopsy performed with three frame devices: Leksell G, Cosman–Roberts–Wells (CRW), and Brown–Roberts–Wells (BRW). A work‐flow analysis will be carried out demonstrating that the accuracy relevant for a clinical application comprises several error sources including imaging, target and entry point selection, image to frame coordinates registration, and the setting of mechanical parameters of the frame. These error sources will be postulated to obey a Gaussian distribution probability density. The linear, i.e., Gaussian, error propagation, will be used to link all error contributions thus to calculate the cumulative accuracy of the frame used in the application. Although the Gaussian approach is an approximation, it allows for an analytical treatment of the accuracy. Both the accuracy at the target point and the accuracy of the probe needle guidance along the planned trajectory have been investigated. Of great significance is the relationship found between accuracy, pixel dimension, and image slice thickness, the latter being the dominant factor for slices of more than 1.5 mm thickness, yielding inaccuracies larger than 1.5 mm. For target points the predictions for the application accuracy have been compared to the results of measurements, showing good agreement with the experimental data.
A qualitative work‐flow analysis of a neurosurgical procedure indicates that the resolution of the image used to plan the intervention is the major source of inaccuracy. Quantitative experimental measurements confirm this observation. They fail, however, to explain the relationship between the accuracy of the frame components involved in a stereotactic procedure and the overall application accuracy. This investigation shows that the novel Gaussian approach is a flexible framework for the calculation of the application accuracy of frame systems. Therefore, the Gaussian approach provides a detailed understanding of the interplay between the various factors affecting accuracy. The basic ideas and limitations of the Gaussian approach are briefly explained. The effect of fiducial marker distribution and registration is investigated and shown to introduce a spatial dependence to the accuracy. The results of the Gaussian approach are compared with experimental data for three stereotactic frame devices: Leksell G, Cosman–Roberts–Wells, and Brown–Roberts–Wells. Although the Gaussian approach is an approximation, it reproduces the accuracy measured in the experiment within the statistical error of that experiment. Comp Aid Surg 4:77–86 (1999). © 1999 Wiley‐Liss, Inc.
Three-dimensional magnetic resonance medical images may contain scanner- and patient-induced geometric distortion. For qualitative diagnosis, geometric errors of a few millimeters are often tolerated. However, quantitative applications such as image-guided neurosurgery and radiotherapy can require an accuracy of a millimeter or better. We have developed a method to accurately measure scanner-induced geometric distortion and to correct the MR images for this type of distortion. The method involves a number of steps. First, a specially designed phantom is scanned that contains a large number of reference structures on positions with a manufacturing error of less than 0.05 mm. Next, the positions of the reference structures are automatically detected in the scanned images and a higher-order polynomial distortion-correction transformation is estimated. Then the patient is scanned and the transformation is applied to correct the patient images for the detected distortion. The distortion-correction method is explained in detail in this paper. The accuracy of the method has been measured with synthetically generated phantom scans that contain an exactly-known amount and type of distortion. The reproducibility of the method has been measured by applying it to a series of consecutive phantom scans. Validation results are briefly described in this paper, a more-detailed description is given in another submission to SPIE Medical Imaging 2001.