Filtern
Erscheinungsjahr
Dokumenttyp
Sprache
- Englisch (50) (entfernen)
Schlagworte
- API 1130 (1)
- CPM (1)
- Deutschland / Technische Regeln für brennbare Flüssigkeiten (1)
- Elektrodenvorbereitung (1)
- Fehlererkennung (1)
- Fehlerortung (1)
- Implantat (1)
- Kernspintomografie (1)
- Kohlenstoff (1)
- Leak detection (1)
Institut
- Elektrotechnik und angewandte Naturwissenschaften (50) (entfernen)
A simplified model for spondylodesis, ie fixation of vertebrae by osteosynthesis, is developed for virtual magnetic resonance imaging (MRI) examinations to numerically calculate energy absorption. This paper presents results of calculated energy absorption in body tissue surrounding titanium rod implants. In general each wire or rod behaves like an antenna in electromagnetic fields. The specific absorption rate (SAR) profile describes dependence of implant size. SAR hotspots appear near the rod edges. Depending of the size of implant fixation SAR is 62%(small fixation) up to 90.95%(large fixation) higher than without implants. In addition, local SAR profile displays local dependency on tissue: SAR is lower between the vertebrae.
Cancer is a leading cause of morbidity and mortality worldwide, with approximately 14 million new cases and 8.2 million cancer related deaths in 2012 [1]. Moreover, the global cancer burden is expected to exceed 20 million new cancer cases by 2025. Understanding the spatial and temporal behaviour of cancer is a crucial precondition to achieve a successful treatment. Because no two cancer cases are the same, every patient should receive a treatment plan designed specifically for her case, in order to improve the patient’s survival chances.
Metallic implants in magnetic resonance imaging (MRI) are a potential safety risk since the energy absorption may increase temperature of the surrounding tissue. The temperature rise is highly dependent on implant size. Numerical examinations can be used to calculate the energy absorption in terms of the specific absorption rate (SAR) induced by MRI on orthopaedic implants. This research presents the impact of titanium osteosynthesis spine implants, called spondylodesis, deduced by numerical examinations of energy absorption in simplified spondylodesis models placed in 1.5 T and 3.0 T MRI body coils. The implants are modelled along with a spine model consisting of vertebrae and disci intervertebrales thus extending previous investigations [1, 2]. Increased SARvalues are observed at the ends of long implants, while at the center SAR is significantly lower. Sufficiently short implants show increased SAR along the complete length of the implant. A careful data analysis reveals that the particular anatomy, i.e. vertebrae and disci intervertebrales, has a significant effect on SAR. On top of SAR profile due to the implant length, considerable SAR variations at small scale are observed, e.g. SAR values at vertebra are higher than at disc positions.
For this experimental work gas diffusion electrodes (GDE) with low platinum loading are prepared for the application as anodes in polymer electrolyte membrane fuel cells. As catalyst support material, carbon nano fibres (CNF) are investigated due to high specific surface area as well as high graphitisation degree. Optimisation is achieved by an economic and environmental friendly pre-treatment process in oxygen plasma. For electrode preparation an ink is used containing oxygen plasma activated CNFs as well as hydrophilic polymer. After spray coating of this CNF ink on a graphitic substrate, platinum is deposited by pulse plating method. Preliminary results established that the plasma activation improves considerably CNF dispersibility as well as the amount, respectively, the morphology of the deposited platinum. Morphology and microstructure are observed by electron microscopy. Platinum loading is determined by thermogravimetric analysis to be in the range of 0.010 to 0.016 mg cm-2. Furthermore, MEAs are prepared from these GDEs and testing is performed in a novel modular test stack based on hydraulic compression. Technical information about the test stack design and functions are given in this work. In this test environment maximum specific power output of 182 mW cm-2 has been obtained under robust operation conditions.
Many fluids transported by pipelines are in some sense hazardous. It is therefore often necessary to install leak detection (and locating) systems (LDS), especially due to legal regulations like the "Code for Federal Regulations (CFR) Title 49 Part 195", API 1130 2nd Ed., both for the USA, or the "Technische Regeln für Fernleitungen" (TRFL) (Technical Rules for Pipelines) in Germany. This paper gives a survey of methodologies, methods and techniques for leak detection and locating. The survey starts with some remarks concerning (legal) regulations both for the USA and for Germany. Some few words about externally based systems (due to API 1130 2nd Ed.) follow next. A significant part of the paper deals with internally based systems (also due to API 1130 2nd Ed.) like balancing systems (line balance, volume balance, compensated mass balance etc.), Real Time Transient Model LDS (RTTM-LDS), pressure/flow monitoring and statistical analysis LDS. Different methods for leak locating (gradient intersection method, wave propagation analysis etc.) will also be shown. The presentation of an Extended RTTM approach (E-RTTM) combining advantages of conventional RTTM LDS and statistical analysis follows next, together with the demonstration of applicability by means of two examples, a liquid multi-batch pipeline, and a gas pipeline. Sketching future work and the conclusion conclude the survey.