Radiotherapy (RT) treatment planning is based on computed tomography (CT) images and traditionally uses the conventional Hounsfield unit (CHU) range. This HU range is suited for human tissue but inappropriate for metallic materials. To guarantee safety of patient carrying implants precise HU quantification is beneficial for accurate dose calculations in planning software. Some modern CT systems offer an extended HU range (EHU). This study focuses the suitability of these two HU ranges for the quantification of metallic components of active implantable medical devices (AIMD). CT acquisitions of various metallic and non-metallic materials aligned in a water phantom were investigated. From our acquisitions we calculated that materials with mass-density ρ > 3.0 g/cm3 cannot be represented in the CHU range. For these materials the EHU range could be used for accurate HU quantification. Since the EHU range does not effect the HU values for materials ρ < 3.0 g/cm3, it can be used as a standard for RT treatment planning for patient with and without implants.
Design and Development of a Bioreactor System for Mechanical Stimulation of Musculoskeletal Tissue
(2023)
We report on the development of a bioreactor system for mechanical stimulation of musculoskeletal tissues. The ultimate object is to improve the quality of medical treatment following injuries of the enthesis tissue. To this end, the tissue formation process through the effect of mechanical stimulation is investigated. A six-well system was designed, 3D printed and tested. An integrated actuator creates strain by applying a force. A contactless position sensor monitors the travels. An electronic circuit controls the bioreactor using a microcontroller. An IoT platform connects the microcontroller to a smartphone, enabling the user to alter variables, trigger actions and monitor the system. The system was stabilised by implementing two PID controllers and safety measures. The results show that the bioreactor design is suited to execute mechanical stimulation and to investigate the tissue formation and regeneration process …
In this research computer tomography (CT) iterative reconstruction (IR) algorithms are investigated, specifically the impact of their statistical and model-based strength on image quality in low-dose lung screening CT protocols in comparison to filtered back projection (FBP). It has been probed whether statistical, model-based IR in conjunction with low-dose, and ultra-low-dose protocols are suitable for lungcancer screening. To this end, artificial lung nodules shaped as spheres and spicules made from material with calibrated Hounsfield units (HU) were attached on marked positions in the lung structure of an anthropomorphic phantom. Nodule positions were selected by distinguished radiologists. The phantom with nodules was scanned on a CT Scanner using standard high contrast (SHC), low-dose (LD) and ultra low-dose (ULD) protocol. For reconstruction FBP and the IR algorithm ADMIRE at three different …
Three-dimensional magnetic resonance medical images may contain scanner- and patient-induced geometric distortion. For qualitative diagnosis, geometric errors of a few millimeters are often tolerated. However, quantitative applications such as image-guided neurosurgery and radiotherapy can require an accuracy of a millimeter or better. We have developed a method to accurately measure scanner-induced geometric distortion and to correct the MR images for this type of distortion. The method involves a number of steps. First, a specially designed phantom is scanned that contains a large number of reference structures on positions with a manufacturing error of less than 0.05 mm. Next, the positions of the reference structures are automatically detected in the scanned images and a higher-order polynomial distortion-correction transformation is estimated. Then the patient is scanned and the transformation is applied to correct the patient images for the detected distortion. The distortion-correction method is explained in detail in this paper. The accuracy of the method has been measured with synthetically generated phantom scans that contain an exactly-known amount and type of distortion. The reproducibility of the method has been measured by applying it to a series of consecutive phantom scans. Validation results are briefly described in this paper, a more-detailed description is given in another submission to SPIE Medical Imaging 2001.
For this experimental work gas diffusion electrodes (GDE) with low platinum loading are prepared for the application as anodes in polymer electrolyte membrane fuel cells. As catalyst support material, carbon nano fibres (CNF) are investigated due to high specific surface area as well as high graphitisation degree. Optimisation is achieved by an economic and environmental friendly pre-treatment process in oxygen plasma. For electrode preparation an ink is used containing oxygen plasma activated CNFs as well as hydrophilic polymer. After spray coating of this CNF ink on a graphitic substrate, platinum is deposited by pulse plating method. Preliminary results established that the plasma activation improves considerably CNF dispersibility as well as the amount, respectively, the morphology of the deposited platinum. Morphology and microstructure are observed by electron microscopy. Platinum loading is determined by thermogravimetric analysis to be in the range of 0.010 to 0.016 mg cm-2. Furthermore, MEAs are prepared from these GDEs and testing is performed in a novel modular test stack based on hydraulic compression. Technical information about the test stack design and functions are given in this work. In this test environment maximum specific power output of 182 mW cm-2 has been obtained under robust operation conditions.
A qualitative work‐flow analysis of a neurosurgical procedure indicates that the resolution of the image used to plan the intervention is the major source of inaccuracy. Quantitative experimental measurements confirm this observation. They fail, however, to explain the relationship between the accuracy of the frame components involved in a stereotactic procedure and the overall application accuracy. This investigation shows that the novel Gaussian approach is a flexible framework for the calculation of the application accuracy of frame systems. Therefore, the Gaussian approach provides a detailed understanding of the interplay between the various factors affecting accuracy. The basic ideas and limitations of the Gaussian approach are briefly explained. The effect of fiducial marker distribution and registration is investigated and shown to introduce a spatial dependence to the accuracy. The results of the Gaussian approach are compared with experimental data for three stereotactic frame devices: Leksell G, Cosman–Roberts–Wells, and Brown–Roberts–Wells. Although the Gaussian approach is an approximation, it reproduces the accuracy measured in the experiment within the statistical error of that experiment. Comp Aid Surg 4:77–86 (1999). © 1999 Wiley‐Liss, Inc.