Filtern
Erscheinungsjahr
- 2015 (37) (entfernen)
Dokumenttyp
Sprache
- Englisch (37) (entfernen)
Schlagworte
- Polymer-Elektrolytmembran-Brennstoffzelle (2)
- adhesion (2)
- Alternative Geschäftsmodelle (1)
- Augmented (1)
- Bionik (1)
- Cell-free implant (1)
- Continuous Queries (1)
- Crowdfunding (1)
- Data Journalism (1)
- Datalog (1)
Institut
- Informatik und Kommunikation (8)
- Westfälisches Energieinstitut (7)
- Maschinenbau Bocholt (5)
- Institut für Internetsicherheit (4)
- Westfälisches Institut für Gesundheit (4)
- Wirtschaft und Informationstechnik Bocholt (2)
- Wirtschaftsrecht (2)
- Elektrotechnik und angewandte Naturwissenschaften (1)
- Institut Arbeit und Technik (1)
- Maschinenbau und Facilities Management (1)
Adhesive organs like arolia of insects allow these animals to climb on different substrates by creating high adhesion forces. According to the Dahlquist criterion, arolia must be very soft exhibiting an effective Young's modulus of below 100 kPa to adhere well to different substrates. In previous studies the effective Young´s moduli of adhesive organs were determined using indentation tests yielding their structure to be very soft indeed. However, arolia show a layered structure, thus the values measured by indentation tests comprise the effective Young´s moduli of the whole organs. In this study, a new approach is illustrated to measure the Young´s modulus of the outermost layer of the arolium, i.e. of the epicuticle, of the stick insect Carausius morosus by tensile testing. Due to the inner fibrous structure of the arolium tensile tests allow the characterisation of the overlying epicuticle.
BACKGROUND: In cartilage repair, scaffold-assisted single-step techniques are used to improve the cartilage regeneration. Nevertheless, the fixation of cartilage implants represents a challenge in orthopaedics, particularly in the moist conditions that pertain during arthroscopic surgery. Within the animal kingdom a broad range of species has developed working solutions to intermittent adhesion under challenging conditions. Using a top-down approach we identified promising mechanisms for biomimetic transfer OBJECTIVE: The tree-frog adhesive system served as a test case to analyze the adhesion capacity of a polyglycolic acid (PGA) scaffold with and without a structural modification in a bovine articular cartilage defect model. METHODS: To this end, PGA implants were modified with a simplified foot-pad structure and evaluated on femoral articular bovine cartilage lesions. Non-structured PGA scaffolds were used as control. Both implants were pressed on 20 mm × 20 mm full-thickness femoral cartilage defects using a dynamometer. RESULTS: The structured scaffolds showed a higher adhesion capacity on the cartilage defect than the non-structured original scaffolds. CONCLUSIONS: The results suggest that the adhesion ability can be increased by means of biomimetic structured surfaces without the need of additional chemical treatment and thus significantly facilitate primary fixation procedures.
Efficient tool to calculate two-dimensional optical spectra for photoactive molecular complexes
(2015)
For this experimental work gas diffusion electrodes (GDE) with low platinum loading are prepared for the application as anodes in polymer electrolyte membrane fuel cells. As catalyst support material, carbon nano fibres (CNF) are investigated due to high specific surface area as well as high graphitisation degree. Optimisation is achieved by an economic and environmental friendly pre-treatment process in oxygen plasma. For electrode preparation an ink is used containing oxygen plasma activated CNFs as well as hydrophilic polymer. After spray coating of this CNF ink on a graphitic substrate, platinum is deposited by pulse plating method. Preliminary results established that the plasma activation improves considerably CNF dispersibility as well as the amount, respectively, the morphology of the deposited platinum. Morphology and microstructure are observed by electron microscopy. Platinum loading is determined by thermogravimetric analysis to be in the range of 0.010 to 0.016 mg cm-2. Furthermore, MEAs are prepared from these GDEs and testing is performed in a novel modular test stack based on hydraulic compression. Technical information about the test stack design and functions are given in this work. In this test environment maximum specific power output of 182 mW cm-2 has been obtained under robust operation conditions.