Filtern
Erscheinungsjahr
Dokumenttyp
- Konferenzveröffentlichung (24)
- Wissenschaftlicher Artikel (14)
- Teil eines Buches (Kapitel) (3)
- Bericht (1)
- Arbeitspapier (1)
Schlagworte
- Polymer-Elektrolytmembran-Brennstoffzelle (3)
- hydraulic compression (2)
- modular stack design (2)
- Elektrolyseure (1)
- Erneuerbare Energien (1)
- Homogene Kühlung (1)
- Hydraulic cell compression (1)
- Hydraulic compression, Carbon Nano Fibers, PEM Fuel Cells, Catalyst utilization (1)
- Hydrogen evolution reaction (1)
- Kohlenstoff-Nanoröhre (1)
- Membran-Elektroden-Einheit (1)
- PEM Electrolysis, Hydrogen, Hydraulic Compression, High Pressure (1)
- PEM electrolysis (1)
- PEM fuel cell (1)
- PEM fuel cell electrocatalysts, Carbon nanofibers, Oxygen plasma activation, Pulsed electroplating. (1)
- PEM fuel cells; electrode preparation; carbon nanofibers; in-situ performance test (1)
- PEM water electrolysis (1)
- PtCoMn (1)
- Stack <Brennstoffzelle> (1)
- Ternary alloy catalyst preparation (1)
- Testsystem (1)
- Upscaling laboratory models (1)
- Wasserstoffenergietechnik (1)
Institut
A compact and efficient PEM electrolyser stack design based on hydraulic single cell compression
(2019)
For this study gas diffusion electrodes (GDE) with low platinum loading are prepared for the application as anode in polymer electrolyte membrane fuel cell (PEMFC) systems based on hydraulic compression. As catalyst support material, carbon nanofibers (CNF) are investigated because of their high specific surface area and high graphitization degree. The electrode preparation is optimized by an economic and environmental friendly pre-treatment process in oxygen plasma. For GDE manufacture an ink containing oxygen plasma activated CNFs as well as hydrophilic polymer is used. After spray coating of this CNF ink on a graphitic substrate, platinum is deposited using the pulse plating technique. Preliminary results showed a considerable improvement of CNF dispersibility as well as an increased amount and an optimized morphology of the deposited platinum. Morphology and microstructure are observed by scanning electron microscopy as well as transmission electron microscopy. Platinum loading is determined by thermogravimetric analysis to be in the range of 0.01 mg cm-2 to 0.017 mg cm-2. Furthermore, MEAs are prepared from these GDEs and testing is performed in a novel modular fuel cell test stack based on hydraulic compression. Technical information about stack design and functions is given in this work.
Membrane electrode assemblies (MEA) developed at the Westphalian Energy Institute for polymer electrolyte membrane fuel cells (PEMFC) are high tech systems containing various materials structured in nanoscale, at which electrochemical reactions occur on catalyst nano particle surfaces. For low reactance homogeneous compression of the MEA’s layers is necessary. A novel stack architecture for electrochemical cells, especially PEMFC as well as PEM electrolysers, has been developed according to achieve ideal cell operation conditions. Single cells of such a stack are inserted into flexible slots that are surrounded by hydraulic media. While operation the hydraulic media is pressurised which leads to an even compression and cooling of the stack’s cells. With this stack design it has been possible to construct a test facility for simultaneous characterisation of several MEA samples. As compression and temperature conditions of every single sample are equal, with the novel test system the effect of e.g. different electrode configurations can be investigated. Furthermore, the modular stack design leads to the development of hybrid energy applications combining fuel cells, electrolysers, batteries as well as metal hydride tanks in one system.
In this experimental work we present a novel electrolyzer system for the production of hydrogen and oxygen at high pressure levels without an additional mechanical compressor. Due to its control strategies, the operation conditions for this electrolyzer can be kept optimal for each load situation of the system. Furthermore, the novel system design allows for dynamic long-term operation as well as for easy maintainability. Therefore, the device meets the requirements for prospective power-to-gas applications, especially, in order to store excess energy from renewable sources. A laboratory scale device has been developed and high-pressure operation was validated. We also studied the long-term stability of the system by applying dynamic load cycles with load changes every 30 sec. After 80 h of operation the used membrane electrode assembly (MEA) was investigated by means of SEM, EDX and XRD analysis.
The membrane electrode assemblies (MEA) for polymer electrolyte membrane fuel cells (PEMFC) developed at the Westphalian Energy Institute are based on oxygen plasma activated carbon nanotubes (CNT) doped with platinum particles. For electrode preparation an ink is used containing the activated CNTs as well as hydrophobic and hydrophilic material in solved form. After this ink is sprayed onto a graphitic substrate platinum particles are deposited by pulse plating method, where the plasma activation enhances CNT dispersibility as well as platinum deposition. This materials mixture is structured in nanoscale with the aim to increase the catalyst particles’ specific surface. For low reactance at operation, homogeneous compression of the MEA’s layers is necessary within a PEMFC. A novel stack architecture for electrochemical cells, especially PEMFC as well as PEM electrolysers, has been developed in order to achieve ideal cell operation conditions. Single cells of such a stack are inserted into flexible slots that are surrounded by a hydraulic medium which is pressurised during operation in order to achieve an even compression and cooling of the stack’s cells. With this stack design it has been possible to construct a test facility for simultaneous characterisation of several MEA samples. As compression and temperature conditions of every single sample are the same, the effects of e.g. different electrode configurations can be investigated with the novel test system.