Filtern
Dokumenttyp
- Konferenzveröffentlichung (21) (entfernen)
Sprache
- Englisch (21) (entfernen)
Schlagworte
- Air handling unit (1)
- Climate change (1)
- Erneuerbare Energien (1)
- Future capacity needs (1)
- Hydraulic compression, Carbon Nano Fibers, PEM Fuel Cells, Catalyst utilization (1)
- Kohlenstoff-Nanoröhre (1)
- PEM Electrolysis, Hydrogen, Hydraulic Compression, High Pressure (1)
- Polymer-Elektrolytmembran-Brennstoffzelle (1)
- Urban heat island (1)
Institut
- Westfälisches Energieinstitut (21) (entfernen)
Air Handling units (AHU) are designed to guarantee a high indoor air quality for any time and outdoor condition all over the year. To do so, the AHU removes particle matter like dust or pollen and adapts the thermophysical properties of air to the desired, seasonal indoor comfort conditions. AHU have a robust design and thus operate for more than fifteen years, sometimes even for decades. An AHU designed today must consider and anticipate the change of user needs as well as outdoor air conditions for the next twenty years. To anticipate the outdoor air condition of coming decades, scientific models exist, which allow the design of peak performance and capacities of the air treatment components. It is most likely, that the ongoing climate change will lead to higher temperatures as well as higher humidity, while the comfort zone of human beings will remain at today’s values. Next to the impact of global warming with average rise of mean air temperature local effects will influence the operation of AHU. On effect investigated here is the steep temperature increase in city centres called urban heat islands. Heating and cooling capacities as well as water consumption for humidification are investigated for a reference AHU for fifteen regional locations in Germany. These regions represent all climate zones within the country. Additionally, the urban heat island effect was investigated for Berlin Alexanderplatz compared a rural area close by. The AHU was chosen to operate in an intensive care unit of a hospital. The set-up leads to 24/7 operation with 8760 hours per year. The article presents the modelling of current and future weather data as well as the unit set up. The calculated hourly performance and capacity parameters for current (reference year 2012) and future weather data (reference year 2045) yield energy consumption and peak loads of the unit for heating, cooling and humidification. The results are displayed by relative comparisons of each performance value.
A compact and efficient PEM electrolyser stack design based on hydraulic single cell compression
(2019)
In this experimental work we present a novel electrolyzer system for the production of hydrogen and oxygen at high pressure levels without an additional mechanical compressor. Due to its control strategies, the operation conditions for this electrolyzer can be kept optimal for each load situation of the system. Furthermore, the novel system design allows for dynamic long-term operation as well as for easy maintainability. Therefore, the device meets the requirements for prospective power-to-gas applications, especially, in order to store excess energy from renewable sources. A laboratory scale device has been developed and high-pressure operation was validated. We also studied the long-term stability of the system by applying dynamic load cycles with load changes every 30 sec. After 80 h of operation the used membrane electrode assembly (MEA) was investigated by means of SEM, EDX and XRD analysis.