Filtern
Erscheinungsjahr
Dokumenttyp
- Wissenschaftlicher Artikel (43) (entfernen)
Schlagworte
- Building Information Modeling (4)
- Kühllastberechnung (4)
- Qualitätsplan (3)
- Reinraumtechnik (3)
- VDI 2078 (3)
- Deutschlandwetter (2)
- Industry Foundation Classes (2)
- Klimaänderung (2)
- Polymer-Elektrolytmembran-Brennstoffzelle (2)
- hydraulic compression (2)
- modular stack design (2)
- carbon nanofibers, platinum electrodeposition, ele ctrochemical surface area (1)
- Aerosol (1)
- Augmented Three-Phase AC-Railgun (1)
- BIM Weiterbildung (1)
- Haustechnik (1)
- Homogene Kühlung (1)
- Hydraulic cell compression (1)
- Hydrogen evolution reaction (1)
- IFC (1)
- Klimatechnik (1)
- Klimawandel (1)
- Laser Synthesis Electrocatalytic Water Splitting (1)
- Lehre (1)
- Lüftungsanlage (1)
- Multiphase Rail Launcher (1)
- Mund-Nasen-Schutz (1)
- PEM electrolysis (1)
- PEM fuel cell (1)
- PEM fuel cell electrocatalysts, Carbon nanofibers, Oxygen plasma activation, Pulsed electroplating. (1)
- PEM water electrolysis (1)
- Praxis (1)
- PtCoMn (1)
- RLT-Auslegung (1)
- RLT-Geräte, Klimawandel, Leistungsreserve (1)
- Raumluft (1)
- Raumluftreiniger (1)
- Raumlufttechnisches Gerät (1)
- SARS-CoV-2 (1)
- Stack <Brennstoffzelle> (1)
- TGA-Büro (1)
- Technische Gebäudeausrüstung (1)
- Ternary alloy catalyst preparation (1)
- Thermal Performance (1)
- Upscaling laboratory models (1)
- Wasserstoff-Kraftwerke (1)
- aerosol (1)
- air hygiene (1)
- airborne infection (1)
- carbon nanofibers, platinum electrodeposition, electrocatalysts (1)
- face mask (1)
- mobile Luftreiniger (1)
- ventilation (1)
Institut
- Westfälisches Energieinstitut (43) (entfernen)
Zentrale Raumlufttechnische Anlagen (RLT-Anlagen) sind für Betriebszeiten von fünfzehn und mehr Jahren konzipiert. Nicht selten werden die Geräte auch nach 25 Jahren Dank Retrofit weiterbetrieben. Unberücksichtigt bleibt dabei, ob die zukünftigen, klimatischen Bedingungen noch der Auslegung entsprechen. Zur Überprüfung der klimatischen Änderungen können sogenannte Testreferenzjahre (TRY – Test Reference Year) genutzt werden. Diese basieren für die heutige Auslegung auf den lokalen, stündlichen Wetterbedingungen im Bezugsjahr 2012 und zusätzlich auf modellbasierten Wetterdaten für das Bezugsjahr 2045.
Das Zentralluftgerät einer Krankenhaus-Intensivstation wurde für die 15 Wetter¬stationen der VDI 4710, Blatt 3 in Deutschland auf die Leistungsanforderungen von heute und für das Jahr 2045 untersucht. Zusätzlich wurden für den Standort Berlin die aktuellen Wetteraufzeichnungen im Sommer 2020 betrachtet. Daraus lassen sich Rückschlüsse ziehen, wie sich städtische Wärmeinseln (UHI – Urban Heat Islands) zukünftig auf den Energie- und Leistungsbedarf zur Gebäudeklimatisierung auswirken werden.
Die Auswirkungen auf die Wärme- und Kältespitzenleistung sowie der kumulierte Energiebedarf werden genauso analysiert wie der Befeuchtungsbedarf. Hieraus lassen sich die potenziellen Leistungsreserven abschätzen und die Klimaresilienz der Anlagentechnik bewerten.
Im zweiten Corona-Winter sollen die Schulen offenbleiben. Neben Fenster- und mechanischer Lüftung werden mobile Raumluftreiniger als sinnvolle Maßnahmen angesehen, um das Infektionsrisiko zu reduzieren. Dabei stellt sich die Frage, wie deren sicherer und zuverlässiger Betrieb gestalten sein muss. Gibt es bevorzugte Aufstellpositionen im Raum und wie wirkt sich die Luftbewegung auf die Behaglichkeit aus? Die Datenlage hierzu ist noch unzureichend (vgl. HLH-Interview mit Dr. Gommel, HLH 10/2021). Diese Fragen werden für einen typischen Seminar- und Klassenraum näher beleuchtet.
As vaccination campaigns are in progress in most countries, hopes to win back more normality are rising. However, the exact path from a pandemic to an endemic virus remains uncertain. While in the pre-vaccination phase many critical indoor situations were avoided by strict control measures, for the transition phase a certain mitigation of the effect of indoor situations seems advisable.
To better understand the mechanisms of indoor airborne transmissions, we present a new time-discrete model to calculate the level of exposure towards infectious SARS-CoV-2 aerosol and carry out a sensitivity analysis for the level of SARS-CoV-2 aerosol exposure in indoor settings. Time limitations and the use of any kind of masks were found to be strong mitigation measures, while how far the effort for a strict use of professional face pieces instead of simple masks can be justified by the additional reduction of the exposure dose remains unclear. Very good ventilation of indoor spaces is mandatory. The definition of sufficient ventilation in regard to airborne SARS-CoV-2 transmission follows other rules than the standards in ventilation design. This means that especially smaller rooms most likely require a significantly greater fresh air supply than usual. Further research on 50% group models in schools is suggested. The benefits of a model in which the students come to school every day, but for a limited time, should be investigated. In terms of window ventilation, it has been found that many short opening periods are not only thermally beneficial, they also reduce the exposure dose. The fresh air supply is driven by the temperature gradient and wind speed. However, the sensitivity towards these parameters is not very high and in times of low wind and temperature gradients, there are no arguments against keep windows open in order to make up for the reduced air flow rate. Long total opening periods and large window surfaces will strongly reduce the exposure. Additionally, the results underline the expectable fact that exposure doses will increase when hygiene and control measures are reduced. It seems advisable to investigate what this means for the infection rate and the fatality of infections in populations with partial immunity. Very basic considerations suggest that the value of aerosol reduction measures may be reduced with very infectious variants such as delta.
Das neuartige Coronavirus SARS-COV-2 wird insbesondere in Innenräumen übertragen. Dabei spielen Aerosole, also kleinste Schwebeteilchen, eine wichtige Rolle. Der längere Aufenthalt in Räumen begünstigt die Wahrscheinlichkeit einer Übertragung auch über eine Distanz von mehr als 1,5 m.
Eine Möglichkeit, um die Schwebeteilchen aus der Raumluft zu entfernen sind Raumluftreiniger. Diese gibt es in verschiedenen Ausführungen und Funktionsprinzipien. Das vorliegende Dokument soll dabei helfen den richtigen Gerätetyp für die jeweilige Anwendung zu finden. Dabei geht es zum einen um große Räume hoher Belegungsdichte (z. B. Schulklassen), zum anderen um Restaurants und Freizeitstätten im öffentlichen Raum. Zu guter Letzt kann der Einsatz dieser Geräte auch im privaten Umfeld sinnvoll sein.
Für alle Geräte gilt: Sie unterstützen die Vermeidung von hohen Virenkonzentrationen im Raum. Das ist jedoch kein Ersatz zum regelmäßigen Lüften und der Zufuhr von „frischer Luft“ und damit mehr Sauerstoff für den Raum.
A systematic method for obtaining a novel electrode structure based on PtCoMn ternary alloy catalyst supported on graphitic carbon nanofibers (CNF) for hydrogen evolution reaction (HER) in acidic media is proposed. Ternary alloy nanoparticles (Co0.6Mn0.4 Pt), with a mean crystallite diameter under 10 nm, were electrodeposited onto a graphitic support material using a two-step pulsed deposition technique. Initially, a surface functionalisation of the carbon nanofibers is performed with the aid of oxygen plasma. Subsequently, a short galvanostatic pulse electrodeposition technique is applied. It has been demonstrated that, if pulsing current is employed, compositionally controlled PtCoMn catalysts can be achieved. Variations of metal concentration ratios in the electrolyte and main deposition parameters, such as current density and pulse shape, led to electrodes with relevant catalytic activity towards HER. The samples were further characterised using several physico-chemical methods to reveal their morphology, structure, chemical and electrochemical properties. X-ray diffraction confirms the PtCoMn alloy formation on the graphitic support and energy dispersive X-ray spectroscopy highlights the presence of the three metallic components from the alloy structure. The preliminary tests regarding the electrocatalytic activity of the developed electrodes display promising results compared to commercial Pt/C catalysts. The PtCoMn/CNF electrode exhibits a decrease in hydrogen evolution overpotential of about 250 mV at 40 mA cm−2 in acidic solution (0.5 M H2SO4) when compared to similar platinum based electrodes (Pt/CNF) and a Tafel slope of around 120 mV dec−1, indicating that HER takes place under the Volmer-Heyrovsky mechanism.
Studies on Pulse Electrodeposition of Pt-Ni binary Alloy For Electrochemical Cell Applications
(2018)
Building Information Modeling (BIM) wird im Bauwesen immer stärker gefordert. Der vorliegende Artikel befasst sich mit dem Datenaustausch für die TGA. Am Beispiel eines RLT-Gerätes werden der Detaillierungsgrad und der Datenaufbau mit IFC erläutert. Insbesondere zeigt sich hierbei, dass der Datenimport aufgrund fehlender Standards und Definitionen mit Datenverlust einhergeht. Damit ergibt sich ein Auftrag an die Softwareunternehmen hier für eindeutige Standards zu sorgen.
TGA-Planung mit BIM-Objekten
(2019)
Die BIM-Methode erfasst in Deutschland mittlerweile alle Gewerke im Bauhauptgewerbe. Für die TGA-Branche hat sich gezeigt, dass die Priorität der Produkthersteller auf der Bereitstellung der Geometriedaten liegt. Weiterführende Metadaten und Attribute (z. B. Material, Masse, Preise, Leistungsdaten) sind oftmals nur in reduzierter Form oder gar nicht vorhanden. An exemplarischen Beispielen von RLT-Reräten und Komponenten werden die geometrischen und semantischen Möglichkeiten beim IFC-Format untersucht.