Filtern
Erscheinungsjahr
Dokumenttyp
- Wissenschaftlicher Artikel (223)
- Konferenzveröffentlichung (200)
- Teil eines Buches (Kapitel) (31)
- Sonstiges (31)
- Buch (Monographie) (13)
- Preprint (12)
- Bericht (4)
- Dissertation (3)
- Lehrmaterial (2)
- Beitrag zu einer (nichtwissenschaftlichen) Zeitung oder Zeitschrift (1)
Sprache
- Englisch (521) (entfernen)
Volltext vorhanden
- nein (521) (entfernen)
Schlagworte
- Dissipative Particle Dynamics (4)
- OCSR (3)
- Polymer-Elektrolytmembran-Brennstoffzelle (3)
- CDK (2)
- DECIMER (2)
- Deep Learning (2)
- Deep learning (2)
- Electrodeposition (2)
- Erweiterte Realität <Informatik> (2)
- Field measurement (2)
Institut
- Westfälisches Institut für Gesundheit (115)
- Westfälisches Energieinstitut (60)
- Institut für Internetsicherheit (55)
- Elektrotechnik und angewandte Naturwissenschaften (49)
- Wirtschaft und Informationstechnik Bocholt (46)
- Institut für biologische und chemische Informatik (44)
- Informatik und Kommunikation (29)
- Maschinenbau Bocholt (21)
- Maschinenbau und Facilities Management (13)
- Wirtschaftsingenieurwesen (13)
Three-dimensional magnetic resonance medical images may contain scanner- and patient-induced geometric distortion. For qualitative diagnosis, geometric errors of a few millimeters are often tolerated. However, quantitative applications such as image-guided neurosurgery and radiotherapy can require an accuracy of a millimeter or better. We have developed a method to accurately measure scanner-induced geometric distortion and to correct the MR images for this type of distortion. The method involves a number of steps. First, a specially designed phantom is scanned that contains a large number of reference structures on positions with a manufacturing error of less than 0.05 mm. Next, the positions of the reference structures are automatically detected in the scanned images and a higher-order polynomial distortion-correction transformation is estimated. Then the patient is scanned and the transformation is applied to correct the patient images for the detected distortion. The distortion-correction method is explained in detail in this paper. The accuracy of the method has been measured with synthetically generated phantom scans that contain an exactly-known amount and type of distortion. The reproducibility of the method has been measured by applying it to a series of consecutive phantom scans. Validation results are briefly described in this paper, a more-detailed description is given in another submission to SPIE Medical Imaging 2001.
Among all additive manufacturing processes, Directed Energy Deposition-Arc (DED-Arc) shows significantly shorter production times and is particularly suitable for large-volume components of simple to medium complexity. To exploit the full potential of this process, the microstructural, mechanical and corrosion behavior have to be studied. High stickout distances lead to a large offset, which leads to an instable electric arc and thus defects such as lack of fusion. Since corrosion preferentially occurs at such defects, the main objective of this work is to investigate the influence of the stickout distance on the corrosion
behavior and microstructure of stainless steel manufactured by DED-Arc.
Within the heterogenous structure of the manufactured samples lack of fusion defects were detected. The quantity of such defects was reduced by applying a shorter stickout distance. The corrosion behavior of the additively manufactured specimens was investigated by means of potentiodynamic polarization measurements. The semi-logarithmic current density potential curves showed a similar course and thus similar corrosion resistance like that of the conventionally forged sample. The polarization curve of the reference material shows numerous current peaks, both in the anodic and cathodic regions. This metastable behavior is induced by the presence of manganese sulfides. On the sample surface a local attack by pitting corrosion was identified.
Cardiac and liver computed tomography (CT) perfusion has not been routinely implemented in the clinic and requires high radiation doses. The purpose of this study is to examine the radiation exposure and technical settings for cardiac and liver CT perfusion scans at different CT scanners. Two cardiac and three liver CT perfusion protocols were examined with the N1 LUNGMAN phantom at three multi-slice CT scanners: a single-source (I) and second- (II) and third-generation (III) dual-source CT scanners. Radiation doses were reported for the CT dose index (CTDIvol) and dose–length product (DLP) and a standardised DLP (DLP10cm) for cardiac and liver perfusion. The effective dose (ED10cm) for a standardised scan length of 10 cm was estimated using conversion factors based on the International Commission on Radiological Protection (ICRP) 110 phantoms and tissue-weighting factors from ICRP 103. The proposed total lifetime attributable risk of developing cancer was determined as a function of organ, age and sex for adults. Radiation exposure for CTDIvol, DLP/DLP10 cm and ED10 cm during CT perfusion was distributed as follows: for cardiac perfusion (II) 144 mGy, 1036 mGy·cm/1440 mGy·cm and 39 mSv, and (III) 28 mGy, 295 mGy·cm/279 mGy·cm and 8 mSv; for liver perfusion (I) 225 mGy, 3360 mGy·cm/2249 mGy·cm and 54 mSv, (II) 94 mGy, 1451 mGy·cm/937 mGy·cm and 22 mSv, and (III) 74 mGy, 1096 mGy·cm/739 mGy·cm and 18 mSv. The third-generation dual-source CT scanner applied the lowest doses. Proposed total lifetime attributable risk increased with decreasing age. Even though CT perfusion is a high-dose examination, we observed that new-generation CT scanners could achieve lower doses. There is a strong impact of organ, age and sex on lifetime attributable risk. Further investigations of the feasibility of these perfusion scans are required for clinical implementation.
The aim of this phantom study is to examine radiation doses of dual- and single-energy computed tomography (DECT and SECT) in the chest and upper abdomen for three different multi-slice CT scanners. A total of 34 CT protocols were examined with the phantom N1 LUNGMAN. Four different CT examination types of different anatomic regions were performed both in single- and dual-energy technique: chest, aorta, pulmonary arteries for suspected pulmonary embolism and liver. Radiation doses were examined for the CT dose index CTDIvol and dose-length product (DLP). Radiation doses of DECT were significantly higher than doses for SECT. In terms of CTDIvol, radiation doses were 1.1–3.2 times higher, and in terms of DLP, these were 1.1–3.8 times higher for DECT compared with SECT. The third-generation dual-source CT applied the lowest dose in 7 of 15 different examination types of different anatomic regions.
We investigate the possibility to use update propagation methods for optimizing the evaluation of continuous queries. Update propagation allows for the efficient determination of induced changes to derived relations resulting from an explicitly performed base table update. In order to simplify the computation process, we propose the propagation of updates with different degrees of granularity which corresponds to an incremental query evaluation with different levels of accuracy. We show how propagation rules for diferent update granularities can be systematically derived, combined and further optimized by using Magic Sets. This way, the costly evaluation of certain subqueries within a continuous query can be systematically circumvented allowing for cutting down on the number of pipelined tuples considerably.
This Article introduces two research projects towards assistive robotic arms for people with severe body impairments. Both projects aim to develop new control and interaction designs to promote accessibility and a better performance for people with functional losses in all four extremities, e.g. due to quadriplegic or multiple sclerosis. The project MobILe concentrates on using a robotic arm as drinking aid and controlling it with smart glasses, eye-tracking and augmented reality. A user oriented development process with participatory methods were pursued which brought new knowledge about the life and care situation of the future target group and the requirements a robotic drinking aid needs to meet. As a consequence the new project DoF-Adaptiv follows an even more participatory approach, including the future target group, their family and professional caregivers from the beginning into decision making and development processes within the project. DoF-Adaptiv aims to simplify the control modalities of assistive robotic arms to enhance the usability of the robotic arm for activities of daily living. lo decide on exemplary activities, like eating or open a door, the future target group, their family and professional caregivers are included in the decision making process. Furthermore all relevant stakeholders will be included in the investigation of ethical, legal and social implications as well as the identification of potential risks. This article will show the importance of the participatory design for the development and research process in MobILe and DoF-Adaptiv.
Design and Development of a Bioreactor System for Mechanical Stimulation of Musculoskeletal Tissue
(2023)
We report on the development of a bioreactor system for mechanical stimulation of musculoskeletal tissues. The ultimate object is to improve the quality of medical treatment following injuries of the enthesis tissue. To this end, the tissue formation process through the effect of mechanical stimulation is investigated. A six-well system was designed, 3D printed and tested. An integrated actuator creates strain by applying a force. A contactless position sensor monitors the travels. An electronic circuit controls the bioreactor using a microcontroller. An IoT platform connects the microcontroller to a smartphone, enabling the user to alter variables, trigger actions and monitor the system. The system was stabilised by implementing two PID controllers and safety measures. The results show that the bioreactor design is suited to execute mechanical stimulation and to investigate the tissue formation and regeneration process …
Opportunities and Challenges in Mixed-Reality for an Inclusive Human-Robot Collaboration Environment
(2018)
This paper presents an approach to enhance robot control using Mixed-Reality. It highlights the opportunities and challenges in the interaction design to achieve a Human-Robot Collaborative environment. In fact, Human-Robot Collaboration is the perfect space for social inclusion. It enables people, who suffer severe physical impairments, to interact with the environment by providing them movement control of an external robotic arm. Now, when discussing about robot control it is important to reduce the visual-split that different input and output modalities carry. Therefore, Mixed-Reality is of particular interest when trying to ease communication between humans and robotic systems.