Filtern
Erscheinungsjahr
- 2021 (27) (entfernen)
Dokumenttyp
- Wissenschaftlicher Artikel (27) (entfernen)
Sprache
- Englisch (27) (entfernen)
Schlagworte
- Aerosol (1)
- Aggregation-prone (1)
- Bone morphogenetic protein 2 (1)
- E. coli SHuffle® T7 (1)
- Electrolysis (1)
- Greek dept crisis (1)
- Hydrophilicity enhanced hBMP2 variant (1)
- In-silico-design (1)
- Lüftungsanlage (1)
- Membrane (1)
- Mund-Nasen-Schutz (1)
- Normalisierung (1)
- Politische Berichterstattung (1)
- Porous Transport Layers (1)
- SARS-CoV-2 (1)
- Thermal Performance (1)
- Twitter (1)
- Twitter <Softwareplattform> (1)
- aerosol (1)
- air hygiene (1)
- airborne infection (1)
- balance (1)
- bioinspired (1)
- biomimetic materials (1)
- biomimicry (1)
- diversity (1)
- entrepreneurial diversity (1)
- entrepreneurship (1)
- face mask (1)
- intersectionality (1)
- neutrality (1)
- noncommuting fluctuations (1)
- normalisation (1)
- pH-shift elution (1)
- political journalism (1)
- quality standards (1)
- quantum dissipation (1)
- relevance (1)
- television news coverage (1)
- ventilation (1)
Institut
- Institut für biologische und chemische Informatik (7)
- Elektrotechnik und angewandte Naturwissenschaften (4)
- Westfälisches Energieinstitut (3)
- Wirtschaft und Informationstechnik Bocholt (3)
- Informatik und Kommunikation (2)
- Maschinenbau Bocholt (2)
- Wirtschaftsingenieurwesen (2)
- Maschinenbau und Facilities Management (1)
A Crypto-Token Based Charging Incentivization
Scheme for Sustainable Light Electric Vehicle
Sharing
(2021)
The ecological impact of shared light electric vehicles (LEV) such as kick scooters is still widely discussed. Especially the fact that the vehicles and batteries are collected using diesel vans in order to charge empty batteries with electricity of unclear origin is perceived as unsustainable. A better option could be to let the users charge the vehicles themselves whenever it is necessary. For this, a decentralized,flexible and easy to install network of off-grid solar charging stations could bring renewable electricity where it is needed without sacrificing the convenience of a free float sharing system. Since the charging stations are powered by solar energy the most efficient way to utilize them would be to charge the vehicles when the sun is shining. In order to make users charge the vehicle it is necessary to provide some form of benefit for
them doing so. This could be either a discount or free rides. A
particularly robust and well-established mechanism is controlling incentives via means of blockchain-based cryptotokens. This paper demonstrates a crypto-token based scheme for incentivizing users to charge sharing vehicles during times of considerable solar irradiation in order to contribute to more sustainable mobility services.
Background: By reviewing image quality and diagnostic perception, the suitability of a statistical model-based iterative reconstruction algorithm in conjunction with low-dose computed tomography for lung cancer screening is investigated.
Methods: Artificial lung nodules shaped as spheres and spiculated spheres made from material with calibrated Hounsfield units were attached on marked positions in the lung structure of anthropomorphic phantoms. The phantoms were scanned using standard high contrast, and two low-dose computed tomography protocols: low-dose and ultra-low-dose. For the reconstruction, the filtered back projection and the iterative reconstruction algorithm ADMIRE at different strength levels (S1–S5) and the kernels Bl57, Br32, Br69 were used. Expert radiologists assessed image quality by performing 4-field-ranking tests and reading all image series to examine the aptitude for the detectability of lung nodules. Signal-to-noise ratio was investigated as objective image quality parameter.
Results: In ranking tests for lung foci detection expert radiologists prefer medium to high iterative reconstruction strength levels. For the standard clinical kernel Bl57 and varying phantom diameter, a noticeable preference for S4 was detected. Experienced radiologists graded filtered back projection reconstructed images with the highest perceptibility. Less experienced readers assessed filtered back projection and iterative reconstruction equally with the highest grades for the Bl57 kernel. Independently of the dose protocol, the signal-to-noise ratio increases with the iterative reconstruction strength level, specifically for Br69 and Bl57.
Conclusions: Subjective image perception does not significantly correlate with the experience of the radiologist, which presumably mirrors reader’s training and accustomed reading adjustments. Regarding signal-to-noise ratio, iterative reconstruction outperforms filtered back projection for spheres and spiculated spheres. Iterative reconstruction matters. It promises to be an alternative to filtered back projection allowing for lung-cancer screening at markedly decreased radiation exposure but comparable or even improved image quality.
This introduction to a special issue about concepts and facets of entrepreneurial diversity serves as a starting point for further discussion and research in this field. For this purpose, we provide information about the roots of the study of diversity and current trends in entrepreneurship research and present a frame for (researching) entrepreneurial diversity. Additionally, we briefly summarize the three papers selected for inclusion in this special issue. Together, they offer insights into the intersections of different diversity dimensions, personality as a deep dimension of team composition, and a general critical reflection on the conceptualization of entrepreneurial diversity. Taken together, the papers in this special issue present new findings and contribute to further advancing the long overdue research on and discussion about diversity in the field of entrepreneurship.
Description and Analysis of Glycosidic Residues in the Largest Open Natural Products Database
(2021)
Flying insects employ elegant optical-flow-based strategies to solve complex tasks such as landing or obstacle avoidance. Roboticists have mimicked these strategies on flying robots with only limited success, because optical flow (1) cannot disentangle distance from velocity and (2) is less informative in the highly important flight direction. Here, we propose a solution to these fundamental shortcomings by having robots learn to estimate distances to objects by their visual appearance. The learning process obtains supervised targets from a stability-based distance estimation approach. We have successfully implemented the process on a small flying robot. For the task of landing, it results in faster, smooth landings. For the task of obstacle avoidance, it results in higher success rates at higher flight speeds. Our results yield improved robotic visual navigation capabilities and lead to a novel hypothesis on insect intelligence: behaviours that were described as optical-flow-based and hardwired actually benefit from learning processes.
Cardiac and liver computed tomography (CT) perfusion has not been routinely implemented in the clinic and requires high radiation doses. The purpose of this study is to examine the radiation exposure and technical settings for cardiac and liver CT perfusion scans at different CT scanners. Two cardiac and three liver CT perfusion protocols were examined with the N1 LUNGMAN phantom at three multi-slice CT scanners: a single-source (I) and second- (II) and third-generation (III) dual-source CT scanners. Radiation doses were reported for the CT dose index (CTDIvol) and dose–length product (DLP) and a standardised DLP (DLP10cm) for cardiac and liver perfusion. The effective dose (ED10cm) for a standardised scan length of 10 cm was estimated using conversion factors based on the International Commission on Radiological Protection (ICRP) 110 phantoms and tissue-weighting factors from ICRP 103. The proposed total lifetime attributable risk of developing cancer was determined as a function of organ, age and sex for adults. Radiation exposure for CTDIvol, DLP/DLP10 cm and ED10 cm during CT perfusion was distributed as follows: for cardiac perfusion (II) 144 mGy, 1036 mGy·cm/1440 mGy·cm and 39 mSv, and (III) 28 mGy, 295 mGy·cm/279 mGy·cm and 8 mSv; for liver perfusion (I) 225 mGy, 3360 mGy·cm/2249 mGy·cm and 54 mSv, (II) 94 mGy, 1451 mGy·cm/937 mGy·cm and 22 mSv, and (III) 74 mGy, 1096 mGy·cm/739 mGy·cm and 18 mSv. The third-generation dual-source CT scanner applied the lowest doses. Proposed total lifetime attributable risk increased with decreasing age. Even though CT perfusion is a high-dose examination, we observed that new-generation CT scanners could achieve lower doses. There is a strong impact of organ, age and sex on lifetime attributable risk. Further investigations of the feasibility of these perfusion scans are required for clinical implementation.