Filtern
Erscheinungsjahr
- 2021 (27) (entfernen)
Dokumenttyp
- Wissenschaftlicher Artikel (27) (entfernen)
Sprache
- Englisch (27) (entfernen)
Schlagworte
- Aerosol (1)
- Aggregation-prone (1)
- Bone morphogenetic protein 2 (1)
- E. coli SHuffle® T7 (1)
- Electrolysis (1)
- Greek dept crisis (1)
- Hydrophilicity enhanced hBMP2 variant (1)
- In-silico-design (1)
- Lüftungsanlage (1)
- Membrane (1)
Institut
- Institut für biologische und chemische Informatik (7)
- Elektrotechnik und angewandte Naturwissenschaften (4)
- Westfälisches Energieinstitut (3)
- Wirtschaft und Informationstechnik Bocholt (3)
- Informatik und Kommunikation (2)
- Maschinenbau Bocholt (2)
- Wirtschaftsingenieurwesen (2)
- Maschinenbau und Facilities Management (1)
Hydrogen produced via water electrolysis powered by renewable electricity or green H2 offers new decarbonization pathways. Proton exchange membrane water electrolysis (PEMWE) is a promising technology although the current density, temperature, and H2 pressure of the PEMWE will have to be increased substantially to curtail the cost of green H2. Here, a porous transport layer for PEMWE is reported, that enables operation at up to 6 A cm−2, 90 °C, and 90 bar H2 output pressure. It consists of a Ti porous sintered layer (PSL) on a low‐cost Ti mesh (PSL/mesh‐PTL) by diffusion bonding. This novel approach does not require a flow field in the bipolar plate. When using the mesh‐PTL without PSL, the cell potential increases significantly due to mass transport losses reaching ca. 2.5 V at 2 A cm−2 and 90 °C.
Cone-Beam computed tomography (CBCT) has become the most important component of modern radiotherapy for positioning tumor patients directly before treatment. In this work we investigate alternations to standard acquisition protocol, called preset, for patients with a tumor in the thoracic region. The effects of the changed acquisition parameters on the image quality are evaluated using the Catphan Phantom and the image analysis software Smári. The weighted CT dose index (CTDIW) is determined in each case and the effects of the different acquisition protocols on the patient dose are classified accordingly. Additionally, the clinical suitability of alternative presets is tested by investigating correctness of image registration using the CIRS thorax phantom. The results show that a significant dose reduction can be achieved. It can be reduced by 51% for a full rotation by adjusting the gantry speed.
The purpose of the paper is to contribute to the inner workings of transformational leadership in the context of organizational change. According to the organizational role theory, role conflict is proposed as a mediator between transformational leadership and affective commitment to change and irritation. Cross-sectional data were collected in a German company in the textiles sector, undergoing a pervasive IT-related change. Confirmatory factor analysis and structural equation modeling was performed for validity and hypothesis testing. The findings suggest that role conflict acts as a full mediator in the relationship between transformational leadership and affective commitment to change, as well as irritation. Transformational leadership is often discussed in terms of change-oriented leadership. Surprisingly, only a few studies have examined the specific impact of transformational leadership on attitudinal outcomes during change processes, yet. Consequently, research on the underlying psychological mechanisms of the relationship is scarce, too.
As vaccination campaigns are in progress in most countries, hopes to win back more normality are rising. However, the exact path from a pandemic to an endemic virus remains uncertain. While in the pre-vaccination phase many critical indoor situations were avoided by strict control measures, for the transition phase a certain mitigation of the effect of indoor situations seems advisable.
To better understand the mechanisms of indoor airborne transmissions, we present a new time-discrete model to calculate the level of exposure towards infectious SARS-CoV-2 aerosol and carry out a sensitivity analysis for the level of SARS-CoV-2 aerosol exposure in indoor settings. Time limitations and the use of any kind of masks were found to be strong mitigation measures, while how far the effort for a strict use of professional face pieces instead of simple masks can be justified by the additional reduction of the exposure dose remains unclear. Very good ventilation of indoor spaces is mandatory. The definition of sufficient ventilation in regard to airborne SARS-CoV-2 transmission follows other rules than the standards in ventilation design. This means that especially smaller rooms most likely require a significantly greater fresh air supply than usual. Further research on 50% group models in schools is suggested. The benefits of a model in which the students come to school every day, but for a limited time, should be investigated. In terms of window ventilation, it has been found that many short opening periods are not only thermally beneficial, they also reduce the exposure dose. The fresh air supply is driven by the temperature gradient and wind speed. However, the sensitivity towards these parameters is not very high and in times of low wind and temperature gradients, there are no arguments against keep windows open in order to make up for the reduced air flow rate. Long total opening periods and large window surfaces will strongly reduce the exposure. Additionally, the results underline the expectable fact that exposure doses will increase when hygiene and control measures are reduced. It seems advisable to investigate what this means for the infection rate and the fatality of infections in populations with partial immunity. Very basic considerations suggest that the value of aerosol reduction measures may be reduced with very infectious variants such as delta.
We study the nonequilibrium dynamics of a quantum system under the influence of two noncommuting fluctuation sources, i.e., purely dephasing fluctuations and relaxational fluctuations. We find that increasing purely dephasing fluctuations suppress increasing relaxation in the quantum system. This effect is further enhanced when both fluctuation sources are fully correlated. These effects arise for medium to strong primary fluctuations already when the secondary fluctuations are weak due to their noncommuting coupling to the quantum system. Dephasing, in contrast, is increased by increasing any of the two fluctuations. Fully correlated fluctuations result in overdamping at much lower system-bath coupling than uncorrelated noncommuting fluctuations. In total, we observe that treating subdominant secondary environmental fluctuations perturbatively leads, as neglecting them, to erroneous conclusions.