Filtern
Erscheinungsjahr
- 2016 (173) (entfernen)
Dokumenttyp
- Wissenschaftlicher Artikel (64)
- Teil eines Buches (Kapitel) (26)
- Konferenzveröffentlichung (25)
- Beitrag zu einer (nichtwissenschaftlichen) Zeitung oder Zeitschrift (18)
- Buch (Monographie) (17)
- Lehrmaterial (11)
- Rezension (6)
- Bericht (5)
- Sonstiges (1)
Volltext vorhanden
- nein (173) (entfernen)
Schlagworte
- Empirische Methoden (2)
- Energiepolitik (2)
- Erneuerbare Energien (2)
- Fachjournalismus (2)
- Kommunikationswissenschaft (2)
- Rechtswissenschaft (2)
- Wissenschaftliches Arbeiten (2)
- open quantum systems (2)
- carbon nanofibers, platinum electrodeposition, ele ctrochemical surface area (1)
- Besondere Ausgleichsregelung (1)
Institut
- Wirtschaftsrecht (80)
- Informatik und Kommunikation (20)
- Institut für Internetsicherheit (14)
- Westfälisches Institut für Gesundheit (13)
- Westfälisches Energieinstitut (11)
- Strategische Projekte (9)
- Wirtschaft und Informationstechnik Bocholt (8)
- Elektrotechnik und angewandte Naturwissenschaften (6)
- Institut für Innovationsforschung und -management (4)
- Maschinenbau und Facilities Management (2)
Metallic implants in magnetic resonance imaging (MRI) are a potential safety risk since the energy absorption may increase temperature of the surrounding tissue. The temperature rise is highly dependent on implant size. Numerical examinations can be used to calculate the energy absorption in terms of the specific absorption rate (SAR) induced by MRI on orthopaedic implants. This research presents the impact of titanium osteosynthesis spine implants, called spondylodesis, deduced by numerical examinations of energy absorption in simplified spondylodesis models placed in 1.5 T and 3.0 T MRI body coils. The implants are modelled along with a spine model consisting of vertebrae and disci intervertebrales thus extending previous investigations [1], [2]. Increased SAR values are observed at the ends of long implants, while at the center SAR is significantly lower. Sufficiently short implants show increased SAR along the complete length of the implant. A careful data analysis reveals that the particular anatomy, i.e. vertebrae and disci intervertebrales, has a significant effect on SAR. On top of SAR profile due to the implant length, considerable SAR variations at small scale are observed, e.g. SAR values at vertebra are higher than at disc positions.
Metallic implants in magnetic resonance imaging (MRI) are a potential safety risk since the energy absorption may increase temperature of the surrounding tissue. The temperature rise is highly dependent on implant size. Numerical examinations can be used to calculate the energy absorption in terms of the specific absorption rate (SAR) induced by MRI on orthopaedic implants. This research presents the impact of titanium osteosynthesis spine implants, called spondylodesis, deduced by numerical examinations of energy absorption in simplified spondylodesis models placed in 1.5 T and 3.0 T MRI body coils. The implants are modelled along with a spine model consisting of vertebrae and disci intervertebrales thus extending previous investigations [1, 2]. Increased SARvalues are observed at the ends of long implants, while at the center SAR is significantly lower. Sufficiently short implants show increased SAR along the complete length of the implant. A careful data analysis reveals that the particular anatomy, i.e. vertebrae and disci intervertebrales, has a significant effect on SAR. On top of SAR profile due to the implant length, considerable SAR variations at small scale are observed, e.g. SAR values at vertebra are higher than at disc positions.
A simplified model for spondylodesis, ie fixation of vertebrae by osteosynthesis, is developed for virtual magnetic resonance imaging (MRI) examinations to numerically calculate energy absorption. This paper presents results of calculated energy absorption in body tissue surrounding titanium rod implants. In general each wire or rod behaves like an antenna in electromagnetic fields. The specific absorption rate (SAR) profile describes dependence of implant size. SAR hotspots appear near the rod edges. Depending of the size of implant fixation SAR is 62%(small fixation) up to 90.95%(large fixation) higher than without implants. In addition, local SAR profile displays local dependency on tissue: SAR is lower between the vertebrae.
Commonly, nanosystems are characterized by their response to time-dependent external fields in the presence of inevitable environmental fluctuations. The direct impact of the external driving on the environment is generally neglected. While this approach is satisfactory for macroscopic systems, on the nanoscale, an interaction of external fields with the environment is often unavoidable on principle. We extend the standard linear response theory of quantum dissipative systems to strongly driven baths. Significant modifications are found for two paradigm examples. First, we evaluate the polarizability of a molecule immersed in a strongly polarizable medium that responds to terahertz radiation. We find an increase of the molecular polarizability by about 30%. Second, we determine the response of a semiconductor quantum dot in close proximity to a metallic nanoparticle. Both are placed in a polarizable medium and exposed to electromagnetic irradiation. We show that the response of the quantum dot is qualitatively modified by the driven nanoparticle, including the generation of an additional channel of stimulated emission.
Cancer is a leading cause of morbidity and mortality worldwide, with approximately 14 million new cases and 8.2 million cancer related deaths in 2012 [1]. Moreover, the global cancer burden is expected to exceed 20 million new cancer cases by 2025. Understanding the spatial and temporal behaviour of cancer is a crucial precondition to achieve a successful treatment. Because no two cancer cases are the same, every patient should receive a treatment plan designed specifically for her case, in order to improve the patient’s survival chances.
Nachdem die Fachgruppe Medieninformatik (FG MI) der Gesellschaft für Informatik e.V. (GI) bereits in den Jahren 2009 und 2010 Workshops zu den Themen „Medieninformatik in Forschung, Lehre und Praxis“ (Herczeg 2009) bzw. „Basismodule und Basiscurricula für die Medieninformatik“ (Herczeg 2010) durchgeführt hat und den Input aus den Workshops in der Folge überwiegend im Kreis der FG-Leitung verarbeitet hat, ist es Zeit mit den dort entstandenen Ideen wieder in die größere Runde zu gehen. Dieser Beitrag ist als Diskussionspapier für den kommenden (aber auch für weitere) Workshop(s) im Bereich der Medieninformatik gedacht. Die Ideen stammen im Wesentlichen aus der Arbeit der FG-Leitung bzw. einzelner engagierter Mitglieder der FG MI. Gemäß der Tradition der FG erheben die Darstellungen keinen Richtlinienanspruch, sondern sollen Diskussionen anregen.
Medienforschung
(2016)
Maßnahmen zur didaktischen Qualifizierung der Lehrenden im Fach Rechtswissenschaft: Ein Überblick
(2016)
Management von Medienmarken
(2016)
Lehrredaktion
(2016)
Kommunikationswissenschaft
(2016)
Interessengerechte Lösung gesucht! Der BGH zu Verlegerbeteiligungen an Ausschüttungen der VG Wort
(2016)
Intelligente Helfer als persönlicher Assistent. Wie sicher und vertrauenswürdig sind Roboter?
(2016)
In this experimental work polymer electrolyte membrane fuel cell (PEMFC) electrodes are analysed, which are prepared by the use of two sorts of carbon nano fibres (CNF) serving as support material for platinum nano particles. Those CNFs, which are heat treated subsequently to their production, have a higher graphitisation degree than fibres as produced. The improved graphitisation degree leads to higher electrical conductivity, which is favourably for the use in PEMFC electrodes. Samples have been analysed, in order to determine graphitisation degree, electrical conductivity, as well as morphology and loading of the prepared electro catalyst. Membrane electrode assemblies manufactured from prepared electrodes are analysed in-situ in a PEM fuel cell test environment. It has been determined that power output for samples containing CNFs with higher graphitisation degree is increased by about 13.5%.
This work deals with the preparation and investigation of PEM fuel cell electrodes, which are obtained using graphene related material (GRM) serving as catalyst support for platinum nanoparticles. Applied GRM are used for the preparation of suspensions in four distinct mixing ratios. Two sorts of GRM have been investigated: carbon nanofibers (CNF) and graphene oxide (GO). Utilized CNFs provide a superior graphitization degree of about 100%, which leads to both high corrosion resistance and low ohmic resistance in PEM fuel cells.
For electrode preparation a GRM containing layer serving as catalyst support is applied onto a gas diffusion layer (GDL). Prior to GRM suspension and deposition onto a GDL, the graphene structures are functionalized by plasma treatment. Due to this step, an improved hydrophilic behavior for facilitating suspension preparation is achieved. In addition, a subsequent platinum nanoparticle deposition by pulsed electrodeposition process is optimized.
Bereits im April 2012 wurde im HZwei Magazin ein Stackkonzept für PEM-Brennstoffzellen vorgestellt, bei dem im Gegensatz zu der heute üblichen bipolaren Zellenanordnung mit mechanischer Verpressung Einzelzellen über ein Hydraulikmedium verpresst werden. Die Vorteile der homogenen Verpressung und Temperierung der Zellen wurden hierbei herausgestellt. Zwischenzeitlich ist basierend auf diesem Ansatz das Labormuster eines PEM-Elektrolyseurs entwickelt worden, bei dem der produzierte Wasserstoff oder auch der Sauerstoff mit hohen Ausgangsdrücken, z.B. auf einem für Power-2-Gas-Anlagen günstigem Druckniveau, direkt bereitgestellt werden kann.
Handbuch Sporttourismus
(2016)
Gelingendes Projektmanagement in der Schule am Beispiel der Potenzialanalyse in der achten Klasse
(2016)
Foliensatz Branding
(2016)