Filtern
Erscheinungsjahr
Dokumenttyp
- Wissenschaftlicher Artikel (237)
- Konferenzveröffentlichung (216)
- Teil eines Buches (Kapitel) (32)
- Sonstiges (31)
- Video (14)
- Buch (Monographie) (13)
- Preprint (12)
- Dissertation (4)
- Bericht (4)
- Arbeitspapier (4)
Sprache
- Englisch (572) (entfernen)
Schlagworte
- Robotik (8)
- Flugkörper (7)
- UAV (7)
- Rettungsrobotik (5)
- Dissipative Particle Dynamics (4)
- Polymer-Elektrolytmembran-Brennstoffzelle (4)
- adhesion (4)
- Bionik (3)
- Deep Learning (3)
- Erweiterte Realität <Informatik> (3)
Institut
- Westfälisches Institut für Gesundheit (115)
- Westfälisches Energieinstitut (61)
- Institut für Internetsicherheit (56)
- Informatik und Kommunikation (51)
- Elektrotechnik und angewandte Naturwissenschaften (50)
- Wirtschaft und Informationstechnik Bocholt (46)
- Institut für biologische und chemische Informatik (44)
- Maschinenbau Bocholt (37)
- Institut Arbeit und Technik (15)
- Wirtschaftsingenieurwesen (15)
- Maschinenbau und Facilities Management (13)
- Institut für Innovationsforschung und -management (11)
- Fachbereiche (9)
- Wirtschaftsrecht (9)
- Mechatronik-Institut Bocholt (2)
- Strategische Projekte (2)
- Institute (1)
Stereotactic frame systems are widely used in neurosurgery. The accuracy of frame devices is considered as a gold standard to which the accuracy of new frameless stereotactic navigation systems is compared. The purpose of this study is to develop a general approach for the prediction of the application accuracy of stereotactic systems. The approach will be applied to the frame‐based biopsy performed with three frame devices: Leksell G, Cosman–Roberts–Wells (CRW), and Brown–Roberts–Wells (BRW). A work‐flow analysis will be carried out demonstrating that the accuracy relevant for a clinical application comprises several error sources including imaging, target and entry point selection, image to frame coordinates registration, and the setting of mechanical parameters of the frame. These error sources will be postulated to obey a Gaussian distribution probability density. The linear, i.e., Gaussian, error propagation, will be used to link all error contributions thus to calculate the cumulative accuracy of the frame used in the application. Although the Gaussian approach is an approximation, it allows for an analytical treatment of the accuracy. Both the accuracy at the target point and the accuracy of the probe needle guidance along the planned trajectory have been investigated. Of great significance is the relationship found between accuracy, pixel dimension, and image slice thickness, the latter being the dominant factor for slices of more than 1.5 mm thickness, yielding inaccuracies larger than 1.5 mm. For target points the predictions for the application accuracy have been compared to the results of measurements, showing good agreement with the experimental data.
The concept of “Internationalisation at Home“ has gained momentum with the increasing digitalization of education and limitations on mobility. Collaborative Online International Learning (COIL) is an innovative, cost-effective instructional method that promotes intercul-tural learning through online collaboration between faculty and students from different countries or locations. The benefits of using COIL courses have been widely recognized, with learners developing intercultural competencies, digital skills, international education experi-ence, and global awareness.
However, multicultural communication in project environments can be complex and demand awareness of cultural variations . The creation and development of effective cross-cultural collectivism, trust, communication, and empathy in leadership is an important ingredient for remote project collaborations success. This is an area that has been least explored in re-search on communication in virtual teams.
The GIPE projects are mainly carried out as so-called Collaborative Online International Learning (COIL) events. However, to gain a “real world“ experience abroad in an intercultural team, students from all partner universities can participate in the Spring School being held for two weeks in Germany and the Germany students present and hand-over the results in the country of the partner university. The main objective of this research was to examine the experiences of students participating in the GIPE project and to evaluate the effectiveness of the project in enhancing intercultural competencies and fostering collaboration among stu-dents from different continents. This paper will also explore the implications of the GIPE project for Education 2.0 considering the COVID-19 pandemic and the future of education delivery and administration transformation.
Cookie notices (or cookie banners) are a popular mechanism for websites to provide (European) Internet users a tool to choose which cookies the site may set. Banner implementations range from merely providing information that a site uses cookies over offering the choice to accepting or denying all cookies to allowing fine-grained control of cookie usage. Users frequently get annoyed by the banner’s pervasiveness as they interrupt “natural” browsing on the Web. As a remedy, different browser extensions have been developed to automate the interaction with cookie banners.
In this work, we perform a large-scale measurement study comparing the effectiveness of extensions for “cookie banner interaction.” We configured the extensions to express different privacy choices (e.g., accepting all cookies, accepting functional cookies, or rejecting all cookies) to understand their capabilities to execute a user’s preferences. The results show statistically significant differences in which cookies are set, how many of them are set, and which types are set—even for extensions that aim to implement the same cookie choice. Extensions for “cookie banner interaction” can effectively reduce the number of set cookies compared to no interaction with the banners. However, all extensions increase the tracking requests significantly except when rejecting all cookies.
Membrane electrode assemblies (MEA) developed at the Westphalian Energy Institute for polymer electrolyte membrane fuel cells (PEMFC) are high tech systems containing various materials structured in nanoscale, at which electrochemical reactions occur on catalyst nano particle surfaces. For low reactance homogeneous compression of the MEA’s layers is necessary. A novel stack architecture for electrochemical cells, especially PEMFC as well as PEM electrolysers, has been developed according to achieve ideal cell operation conditions. Single cells of such a stack are inserted into flexible slots that are surrounded by hydraulic media. While operation the hydraulic media is pressurised which leads to an even compression and cooling of the stack’s cells. With this stack design it has been possible to construct a test facility for simultaneous characterisation of several MEA samples. As compression and temperature conditions of every single sample are equal, with the novel test system the effect of e.g. different electrode configurations can be investigated. Furthermore, the modular stack design leads to the development of hybrid energy applications combining fuel cells, electrolysers, batteries as well as metal hydride tanks in one system.
In this work, a novel polymer electrolyte membrane water electrolyzer (PEMWE) test cell based on hydraulic single-cell compression is described. In this test cell, the current density distribution is almost homogeneous over the active cell area due to hydraulic cell clamping. As the hydraulic medium entirely surrounds the active cell components, it is also used to control cell temperature resulting in even temperature distribution. The PEMWE single-cell test system based on hydraulic compression offers a 25 cm2 active surface area (5.0 × 5.0 cm) and can be operated up to 80°C and 6.0 A/cm2. Construction details and material selection for the designed test cell are given in this document. Furthermore, findings related to pressure distribution analyzed by utilizing a pressure-sensitive foil, the cell performance indicated by polarization curves, and the reproducibility of results are described. Experimental data indicate the applicability of the presented testing device for relevant PEMWE component testing and material analysis.
In this experimental work we present a novel electrolyzer system for the production of hydrogen and oxygen at high pressure levels without an additional mechanical compressor. Due to its control strategies, the operation conditions for this electrolyzer can be kept optimal for each load situation of the system. Furthermore, the novel system design allows for dynamic long-term operation as well as for easy maintainability. Therefore, the device meets the requirements for prospective power-to-gas applications, especially, in order to store excess energy from renewable sources. A laboratory scale device has been developed and high-pressure operation was validated. We also studied the long-term stability of the system by applying dynamic load cycles with load changes every 30 sec. After 80 h of operation the used membrane electrode assembly (MEA) was investigated by means of SEM, EDX and XRD analysis.
A Robust Interface for Head Motion based Control of a Robot Arm using MARG and Visual Sensors
(2018)
Head-controlled human machine interfaces have gained popularity over the past years, especially in the restoration of the autonomy of severely disabled people, like tetraplegics. These interfaces need to be reliable and robust regarding the environmental conditions to guarantee safety of the user and enable a direct interaction between a human and a machine. This paper presents a hybrid MARG and visual sensor system for head orientation estimation which is in this case used to teleoperate a robotic arm. The system contains a Magnetic Angular Rate Gravity (MARG)-sensor and a Tobii eye tracker 4C. A MARG sensor consists of tri-axis accelerometer, gyroscope as well as a magnetometer which enable a complete measurement of orientation relative to the direction of gravity and magnetic field of the earth. The tri-axis magnetometer is sensitive to external magnetic fields which result in incorrect orientation estimation from the sensor fusion process. In this work the Tobii eye tracker 4C is used to increase head orientation estimation because it also features head tracking even though it is commonly used for eye tracking. This type of visual sensor does not suffer magnetic drift. However, it computes orientation data only, if a user is detectable. Within this work a state machine is presented which enables data fusion of the MARG and visual sensor to improve orientation estimation. The fusion of the orientation data of MARG and visual sensors enables a robust interface, which is immune against external magnetic fields. Therefore, it increases the safety of the human machine interaction.