Filtern
Erscheinungsjahr
- 2016 (21) (entfernen)
Dokumenttyp
- Wissenschaftlicher Artikel (21) (entfernen)
Sprache
- Englisch (21) (entfernen)
Schlagworte
- open quantum systems (2)
- carbon nanofibers, platinum electrodeposition, ele ctrochemical surface area (1)
- Anorganische Analyse (1)
- Biomedical monitoring, Hospitals, Electrocardiography, Wireless communication, Patient monitoring, Wireless sensor networks (1)
- Data Collection (1)
- Europe (1)
- Flügelform (1)
- ICP-Massenspektrometrie (1)
- Implantat (1)
- Kernspintomografie (1)
- Mapping (1)
- Methodology (1)
- Ohrwurm (1)
- PEM fuel cell electrocatalysts, Carbon nanofibers, Oxygen plasma activation, Pulsed electroplating. (1)
- Polymere (1)
- Social Innovation (1)
- Spondylodese (1)
- Stellite 6; HVOF-spraying; Laser remelting; Cavitation erosion; Coatings (1)
- carbon nanofibers, platinum electrodeposition, electrocatalysts (1)
- conical intersection (1)
- demagnetization cooling (1)
- ethics (1)
- expert interviews (1)
- international comparative study (1)
- media accountability (1)
- nonadiabatic dynamics (1)
- nonequilibrium quantum transport (1)
- role identity (1)
- watchblogs (1)
- Änderung (1)
Institut
- Wirtschaft und Informationstechnik Bocholt (5)
- Westfälisches Energieinstitut (4)
- Elektrotechnik und angewandte Naturwissenschaften (3)
- Westfälisches Institut für Gesundheit (3)
- Maschinenbau Bocholt (2)
- Informatik und Kommunikation (1)
- Institut Arbeit und Technik (1)
- Maschinenbau und Facilities Management (1)
- Wirtschaftsingenieurwesen (1)
We show that strong non-Markovian effects can be revealed by the steady-state two-dimensional (2D) photon echo spectra at asymptotic waiting times. For this, we use a simple dimer toy model that is strongly coupled to a harmonic bath with parameters typical for photoactive biomolecules. We calculate the 2D photon echo spectra employing both the numerically exact hierarchy equation of motion and the quasiadiabatic path integral approach and compare these results with approximate results from a time-nonlocal quantum master equation approach. While the latter correctly reproduces the exact population dynamics at long times, it fails at the same time to correctly describe the 2D photon echo spectra at long waiting times. The differences show that non-Markovian effects are much more important for the steady-state 2D photon echoes than for the equilibrium populations. Thus, accurate theoretical descriptions of the energy transfer dynamics in biomolecular complexes have to be based on numerically exact simulations of the environmental fluctuations when nonlinear response functions are analyzed.
The two-state two-path model is introduced as a minimized model to describe the quantum dynamics of an electronic wave packet in the vicinity of a conical intersection. It involves two electronic potential energy surfaces each of which hosts a pair of quasi-classical trajectories over which the wave packet is assumed to be delocalized. When both trajectories evolve dynamically either diabatically or adiabatically, the full wave packet dynamics shows only features of the dynamics around avoided level crossings in the vicinity of the conical intersection. When one trajectory evolves adiabatically whereas the other trajectory follows a diabatic evolution, quantum mechanical interference of the wave packet components on each path generates Stueckelberg oscillations in the transition probability. These are surprisingly robust against a dissipative environment and, thus, should be a marker for conical intersections.
Earwig wings are highly foldable structures that lack internal muscles. The behaviour and shape changes of the wings during flight are yet unknown. We assume that they meet a great structural challenge to control the occurring deformations and prevent the wing from collapsing. At the folding structures especially, the wing could easily yield to the pressure. Detailed microscopy studies reveal adaptions in the structure and material which are not relevant for folding purposes. The wing is parted into two structurally different areas with, for example, a different trend or stiffness of the wing veins. The storage of stiff or more flexible material shows critical areas which undergo great changes or stress during flight. We verified this with high-speed video recordings. These reveal the extent of the occurring deformations and their locations, and support our assumptions. The video recordings reveal a dynamical change of a concave flexion line. In the static unfolded state, this flexion line blocks a folding line, so that the wing stays unfolded. However, during flight it extends and blocks a second critical folding line and prevents the wing from collapsing. With these results, more insight in passive wing control, especially within high foldable structures, is gained.
Optimization of the laser remelting process for HVOF-sprayed Stellite 6 wear resistant coatings
(2016)
Cobalt base alloys are used in all industrial areas due to their excellent wear resistance. Several studies have shown that Stellite 6 coatings are suitable not only for protection against sliding wear, but also in case of exposure to impact loading. In this respect, a possible application is the protection of hydropower plant components affected by cavitation. The main problem in connection with Stellite 6 is the deposition procedure of the protective layers, both welding and thermal spraying techniques requesting special measures in order to prevent the brittleness of the coating. In this study, Stellite 6 layers were HVOF thermally sprayed on a martensitic 13-4 stainless steel substrate, as usually used for hydraulic machinery components. In order to improve the microstructure of the HVOF-sprayed coatings and their adhesion to the substrate, laser remelting was applied, using a TRUMPF Laser type HL 124P LCU and different working parameters. The microstructure of the coatings, obtained for various remelting conditions, was evaluated by light microscopy, showing the optimal value of the pulse power, which provided a homogenous Stellite 6 layer with good adhesion to the substrate.
Platinum nanoparticles electrodeposition on carbon nanofibers (CNF) support has been performed with the purpose to obtain electrodes that can be further used especially in a polymer electrolyte membrane fuel cell (PEMFC). A pretreatment of CNF is required in order to enhance the surface energy, which simultaneously improves handling and wettability as well as interaction with the platinum cations. This step was performed using oxygen plasma functionalization. To produce CNF supported Pt catalysts, an electrochemical method was applied and the deposition parameters were adjusted to obtain nanosized platinum particles with a good distribution onto the graphitic surface. The morphology and structure of the obtained particles were investigated by scanning electron microscopy combined with energy dispersive X-Ray spectroscopy. The amount of deposited platinum was established using thermogravimetrical measurements. Cyclic voltammetry performed in 0.5 M H2SO4 solution was applied for determining the electrochemical surface area (ECSA) of the obtained electrodes.The functionalization degree of the CNF outer surface has a strong influence on the structure, distribution and amount of platinum particles. Moreover, the current densities, which were set for the deposition process influenced not only the particles size but also the platinum amount. Applying an oxygen plasma treatment of 80 W for 1800 s, the necessary degree of surface functionalization is achieved in order to deposit the catalyst particles. The best electrodes were prepared using a current density of 50 mA cm-2 during the deposition process that leads to a homogenous platinum distribution with particles size under 80 nm and ECSA over 6 cm2
Metallic implants in magnetic resonance imaging (MRI) are a potential safety risk since the energy absorption may increase temperature of the surrounding tissue. The temperature rise is highly dependent on implant size. Numerical examinations can be used to calculate the energy absorption in terms of the specific absorption rate (SAR) induced by MRI on orthopaedic implants. This research presents the impact of titanium osteosynthesis spine implants, called spondylodesis, deduced by numerical examinations of energy absorption in simplified spondylodesis models placed in 1.5 T and 3.0 T MRI body coils. The implants are modelled along with a spine model consisting of vertebrae and disci intervertebrales thus extending previous investigations [1], [2]. Increased SAR values are observed at the ends of long implants, while at the center SAR is significantly lower. Sufficiently short implants show increased SAR along the complete length of the implant. A careful data analysis reveals that the particular anatomy, i.e. vertebrae and disci intervertebrales, has a significant effect on SAR. On top of SAR profile due to the implant length, considerable SAR variations at small scale are observed, e.g. SAR values at vertebra are higher than at disc positions.
Metallic implants in magnetic resonance imaging (MRI) are a potential safety risk since the energy absorption may increase temperature of the surrounding tissue. The temperature rise is highly dependent on implant size. Numerical examinations can be used to calculate the energy absorption in terms of the specific absorption rate (SAR) induced by MRI on orthopaedic implants. This research presents the impact of titanium osteosynthesis spine implants, called spondylodesis, deduced by numerical examinations of energy absorption in simplified spondylodesis models placed in 1.5 T and 3.0 T MRI body coils. The implants are modelled along with a spine model consisting of vertebrae and disci intervertebrales thus extending previous investigations [1, 2]. Increased SARvalues are observed at the ends of long implants, while at the center SAR is significantly lower. Sufficiently short implants show increased SAR along the complete length of the implant. A careful data analysis reveals that the particular anatomy, i.e. vertebrae and disci intervertebrales, has a significant effect on SAR. On top of SAR profile due to the implant length, considerable SAR variations at small scale are observed, e.g. SAR values at vertebra are higher than at disc positions.
Commonly, nanosystems are characterized by their response to time-dependent external fields in the presence of inevitable environmental fluctuations. The direct impact of the external driving on the environment is generally neglected. While this approach is satisfactory for macroscopic systems, on the nanoscale, an interaction of external fields with the environment is often unavoidable on principle. We extend the standard linear response theory of quantum dissipative systems to strongly driven baths. Significant modifications are found for two paradigm examples. First, we evaluate the polarizability of a molecule immersed in a strongly polarizable medium that responds to terahertz radiation. We find an increase of the molecular polarizability by about 30%. Second, we determine the response of a semiconductor quantum dot in close proximity to a metallic nanoparticle. Both are placed in a polarizable medium and exposed to electromagnetic irradiation. We show that the response of the quantum dot is qualitatively modified by the driven nanoparticle, including the generation of an additional channel of stimulated emission.
Cancer is a leading cause of morbidity and mortality worldwide, with approximately 14 million new cases and 8.2 million cancer related deaths in 2012 [1]. Moreover, the global cancer burden is expected to exceed 20 million new cancer cases by 2025. Understanding the spatial and temporal behaviour of cancer is a crucial precondition to achieve a successful treatment. Because no two cancer cases are the same, every patient should receive a treatment plan designed specifically for her case, in order to improve the patient’s survival chances.