Filtern
Erscheinungsjahr
- 2016 (42) (entfernen)
Dokumenttyp
- Wissenschaftlicher Artikel (18)
- Konferenzveröffentlichung (17)
- Teil eines Buches (Kapitel) (4)
- Buch (Monographie) (2)
- Bericht (1)
Sprache
- Englisch (42) (entfernen)
Volltext vorhanden
- nein (42) (entfernen)
Schlagworte
- open quantum systems (2)
- carbon nanofibers, platinum electrodeposition, ele ctrochemical surface area (1)
- Biomedical monitoring, Hospitals, Electrocardiography, Wireless communication, Patient monitoring, Wireless sensor networks (1)
- Current Pulses (1)
- Flat-Channel (1)
- Hydraulic compression, Carbon Nano Fibers, PEM Fuel Cells, Catalyst utilization (1)
- Implantat (1)
- Kernspintomografie (1)
- Launcher (1)
- PEM fuel cell electrocatalysts, Carbon nanofibers, Oxygen plasma activation, Pulsed electroplating. (1)
- Sinusoidal (1)
- Spondylodese (1)
- Stellite 6; HVOF-spraying; Laser remelting; Cavitation erosion; Coatings (1)
- Thermal Stress (1)
- carbon nanofibers, platinum electrodeposition, electrocatalysts (1)
- conical intersection (1)
- demagnetization cooling (1)
- ethics (1)
- expert interviews (1)
- infrared heating panel (1)
- international comparative study (1)
- media accountability (1)
- nonadiabatic dynamics (1)
- nonequilibrium quantum transport (1)
- role identity (1)
- watchblogs (1)
Institut
- Westfälisches Energieinstitut (10)
- Westfälisches Institut für Gesundheit (10)
- Wirtschaft und Informationstechnik Bocholt (6)
- Elektrotechnik und angewandte Naturwissenschaften (5)
- Informatik und Kommunikation (3)
- Wirtschaftsrecht (3)
- Institut für Innovationsforschung und -management (1)
- Institut für Internetsicherheit (1)
- Maschinenbau Bocholt (1)
- Maschinenbau und Facilities Management (1)
We present a scheme for cooling a vibrational mode of a magnetic molecular nanojunction by a spin-polarized charge current upon exploiting the interaction between its magnetic moment and the vibration. The spin-polarized charge current polarizes the magnetic moment of the nanoisland, thereby lowering its energy. A small but finite coupling between the vibration and the magnetic moment permits a direct exchange of energy such that vibrational energy can be transferred into the magnetic state. For positive bias voltages, this generates an effective cooling of the molecular vibrational mode. We determine parameter regimes for the cooling of the vibration to be optimal. Although the flowing charge current inevitably heats up the vibrational mode via Ohmic energy losses, we show that due to the magnetomechanical coupling, the vibrational energy (i.e, the effective phonon temperature) can be lowered below 50% of its initial value, when the two leads are polarized anti-parallel. In contrast to the cooling effect for positive bias voltages, net heating of the vibrational mode occurs for negative bias voltages. The cooling effect is enhanced for a stronger anti-parallel magnetic polarization of the leads, while the heating is stronger for a larger parallel polarization. Yet, dynamical cooling is also possible with parallel lead alignments when the two tunneling barriers are asymmetric.
Optimization of the laser remelting process for HVOF-sprayed Stellite 6 wear resistant coatings
(2016)
Cobalt base alloys are used in all industrial areas due to their excellent wear resistance. Several studies have shown that Stellite 6 coatings are suitable not only for protection against sliding wear, but also in case of exposure to impact loading. In this respect, a possible application is the protection of hydropower plant components affected by cavitation. The main problem in connection with Stellite 6 is the deposition procedure of the protective layers, both welding and thermal spraying techniques requesting special measures in order to prevent the brittleness of the coating. In this study, Stellite 6 layers were HVOF thermally sprayed on a martensitic 13-4 stainless steel substrate, as usually used for hydraulic machinery components. In order to improve the microstructure of the HVOF-sprayed coatings and their adhesion to the substrate, laser remelting was applied, using a TRUMPF Laser type HL 124P LCU and different working parameters. The microstructure of the coatings, obtained for various remelting conditions, was evaluated by light microscopy, showing the optimal value of the pulse power, which provided a homogenous Stellite 6 layer with good adhesion to the substrate.
We show that strong non-Markovian effects can be revealed by the steady-state two-dimensional (2D) photon echo spectra at asymptotic waiting times. For this, we use a simple dimer toy model that is strongly coupled to a harmonic bath with parameters typical for photoactive biomolecules. We calculate the 2D photon echo spectra employing both the numerically exact hierarchy equation of motion and the quasiadiabatic path integral approach and compare these results with approximate results from a time-nonlocal quantum master equation approach. While the latter correctly reproduces the exact population dynamics at long times, it fails at the same time to correctly describe the 2D photon echo spectra at long waiting times. The differences show that non-Markovian effects are much more important for the steady-state 2D photon echoes than for the equilibrium populations. Thus, accurate theoretical descriptions of the energy transfer dynamics in biomolecular complexes have to be based on numerically exact simulations of the environmental fluctuations when nonlinear response functions are analyzed.
Commonly, nanosystems are characterized by their response to time-dependent external fields in the presence of inevitable environmental fluctuations. The direct impact of the external driving on the environment is generally neglected. While this approach is satisfactory for macroscopic systems, on the nanoscale, an interaction of external fields with the environment is often unavoidable on principle. We extend the standard linear response theory of quantum dissipative systems to strongly driven baths. Significant modifications are found for two paradigm examples. First, we evaluate the polarizability of a molecule immersed in a strongly polarizable medium that responds to terahertz radiation. We find an increase of the molecular polarizability by about 30%. Second, we determine the response of a semiconductor quantum dot in close proximity to a metallic nanoparticle. Both are placed in a polarizable medium and exposed to electromagnetic irradiation. We show that the response of the quantum dot is qualitatively modified by the driven nanoparticle, including the generation of an additional channel of stimulated emission.
Metallic implants in magnetic resonance imaging (MRI) are a potential safety risk since the energy absorption may increase temperature of the surrounding tissue. The temperature rise is highly dependent on implant size. Numerical examinations can be used to calculate the energy absorption in terms of the specific absorption rate (SAR) induced by MRI on orthopaedic implants. This research presents the impact of titanium osteosynthesis spine implants, called spondylodesis, deduced by numerical examinations of energy absorption in simplified spondylodesis models placed in 1.5 T and 3.0 T MRI body coils. The implants are modelled along with a spine model consisting of vertebrae and disci intervertebrales thus extending previous investigations [1], [2]. Increased SAR values are observed at the ends of long implants, while at the center SAR is significantly lower. Sufficiently short implants show increased SAR along the complete length of the implant. A careful data analysis reveals that the particular anatomy, i.e. vertebrae and disci intervertebrales, has a significant effect on SAR. On top of SAR profile due to the implant length, considerable SAR variations at small scale are observed, e.g. SAR values at vertebra are higher than at disc positions.
Metallic implants in magnetic resonance imaging (MRI) are a potential safety risk since the energy absorption may increase temperature of the surrounding tissue. The temperature rise is highly dependent on implant size. Numerical examinations can be used to calculate the energy absorption in terms of the specific absorption rate (SAR) induced by MRI on orthopaedic implants. This research presents the impact of titanium osteosynthesis spine implants, called spondylodesis, deduced by numerical examinations of energy absorption in simplified spondylodesis models placed in 1.5 T and 3.0 T MRI body coils. The implants are modelled along with a spine model consisting of vertebrae and disci intervertebrales thus extending previous investigations [1, 2]. Increased SARvalues are observed at the ends of long implants, while at the center SAR is significantly lower. Sufficiently short implants show increased SAR along the complete length of the implant. A careful data analysis reveals that the particular anatomy, i.e. vertebrae and disci intervertebrales, has a significant effect on SAR. On top of SAR profile due to the implant length, considerable SAR variations at small scale are observed, e.g. SAR values at vertebra are higher than at disc positions.
A simplified model for spondylodesis, ie fixation of vertebrae by osteosynthesis, is developed for virtual magnetic resonance imaging (MRI) examinations to numerically calculate energy absorption. This paper presents results of calculated energy absorption in body tissue surrounding titanium rod implants. In general each wire or rod behaves like an antenna in electromagnetic fields. The specific absorption rate (SAR) profile describes dependence of implant size. SAR hotspots appear near the rod edges. Depending of the size of implant fixation SAR is 62%(small fixation) up to 90.95%(large fixation) higher than without implants. In addition, local SAR profile displays local dependency on tissue: SAR is lower between the vertebrae.
The wireless data logger system “Cor/log® BAN BT” (CL) allows seamless 24/7 monitoring of relevant vital sign parameters. CL covers the entire period of acute point of care inside the hospital and the recovery period, when first mobility is achieved and when the patient is released into an ambulatory or homecare environment. The CL records the relevant vital signs such as ECG, respiration, pulse oximetry with plethysmogram and movement. The vital data collected with the CL data logger is saved on a memory card for further analysis and is simultaneously transmitted in real-time to a telemedicine server via a smartphone or tablet. The smartphone also provides GPS location information. In addition Cor/log View, an Android Application for viewing recorded vital sign data originating from the CL, was developed. CL has also a connector to the generic MedM health cloud. MedM is a generic patient data management system (PDMS) consisting of a cloud portal and a mobile health app. The app runs on Android, iOS and Windows. The app can connects wirelessly to the CL physiologic monitor and stores the vital signs in the cloud.
Thermal Stress at the Surface of Thick Conductive Plates Induced by Sinusoidal Current Pulses
(2016)
Platinum nanoparticles electrodeposition on carbon nanofibers (CNF) support has been performed with the purpose to obtain electrodes that can be further used especially in a polymer electrolyte membrane fuel cell (PEMFC). A pretreatment of CNF is required in order to enhance the surface energy, which simultaneously improves handling and wettability as well as interaction with the platinum cations. This step was performed using oxygen plasma functionalization. To produce CNF supported Pt catalysts, an electrochemical method was applied and the deposition parameters were adjusted to obtain nanosized platinum particles with a good distribution onto the graphitic surface. The morphology and structure of the obtained particles were investigated by scanning electron microscopy combined with energy dispersive X-Ray spectroscopy. The amount of deposited platinum was established using thermogravimetrical measurements. Cyclic voltammetry performed in 0.5 M H2SO4 solution was applied for determining the electrochemical surface area (ECSA) of the obtained electrodes.The functionalization degree of the CNF outer surface has a strong influence on the structure, distribution and amount of platinum particles. Moreover, the current densities, which were set for the deposition process influenced not only the particles size but also the platinum amount. Applying an oxygen plasma treatment of 80 W for 1800 s, the necessary degree of surface functionalization is achieved in order to deposit the catalyst particles. The best electrodes were prepared using a current density of 50 mA cm-2 during the deposition process that leads to a homogenous platinum distribution with particles size under 80 nm and ECSA over 6 cm2