Filtern
Erscheinungsjahr
Dokumenttyp
- Wissenschaftlicher Artikel (55) (entfernen)
Schlagworte
- Building Information Modeling (4)
- Kühllastberechnung (4)
- Qualitätsplan (3)
- Reinraumtechnik (3)
- VDI 2078 (3)
- Deutschlandwetter (2)
- Industry Foundation Classes (2)
- Klimaänderung (2)
- Polymer-Elektrolytmembran-Brennstoffzelle (2)
- hydraulic compression (2)
- modular stack design (2)
- water electrolysis (2)
- carbon nanofibers, platinum electrodeposition, ele ctrochemical surface area (1)
- Aerosol (1)
- Augmented (1)
- Augmented Electromagnetic Accelerators (1)
- Augmented Multiphase (1)
- Augmented Multiphase Rail Launcher (1)
- Augmented Three-Phase AC-Railgun (1)
- BIM Weiterbildung (1)
- Catalysis (1)
- Electrodeposition (1)
- Electrolysis (1)
- Electromagnetic Launcher (1)
- Energy Storage Mode (1)
- Gas Diffusion Electrode (1)
- Haustechnik (1)
- Homogene Kühlung (1)
- Hydraulic cell compression (1)
- Hydrogen evolution reaction (1)
- IFC (1)
- Klimatechnik (1)
- Klimawandel (1)
- Laser Synthesis Electrocatalytic Water Splitting (1)
- Lehre (1)
- Linear Electromagnetic Accelerator (1)
- Lüftungsanlage (1)
- Magnetic Pressure (1)
- Membrane (1)
- Modular Augmented Launcher (1)
- Modular Design (1)
- Multiphase Rail Launcher (1)
- Mund-Nasen-Schutz (1)
- Muzzle Velocity (1)
- ORR OER (1)
- PEM electrolysis (1)
- PEM fuel cell (1)
- PEM fuel cell electrocatalysts, Carbon nanofibers, Oxygen plasma activation, Pulsed electroplating. (1)
- PEM water electrolysis (1)
- PEMWE (1)
- Porous Transport Layers (1)
- Praxis (1)
- PtCoMn (1)
- RLT-Auslegung (1)
- RLT-Geräte, Klimawandel, Leistungsreserve (1)
- Rail Launcher (1)
- Railgun (1)
- Raumluft (1)
- Raumluftreiniger (1)
- Raumlufttechnisches Gerät (1)
- SARS-CoV-2 (1)
- Semi-Infinite Plate (1)
- Stack <Brennstoffzelle> (1)
- TGA-Büro (1)
- Technische Gebäudeausrüstung (1)
- Ternary alloy catalyst preparation (1)
- Thermal Performance (1)
- Upscaling laboratory models (1)
- Wasserstoff-Kraftwerke (1)
- aerosol (1)
- air hygiene (1)
- airborne infection (1)
- bipolar plate (1)
- carbon nanofibers, platinum electrodeposition, electrocatalysts (1)
- coatings (1)
- corrosion resistance (1)
- face mask (1)
- hydraulic cell compression (1)
- mobile Luftreiniger (1)
- novel (1)
- polymer electrolyte membrane (1)
- ventilation (1)
Institut
- Westfälisches Energieinstitut (55) (entfernen)
In this work, a novel polymer electrolyte membrane water electrolyzer (PEMWE) test cell based on hydraulic single-cell compression is described. In this test cell, the current density distribution is almost homogeneous over the active cell area due to hydraulic cell clamping. As the hydraulic medium entirely surrounds the active cell components, it is also used to control cell temperature resulting in even temperature distribution. The PEMWE single-cell test system based on hydraulic compression offers a 25 cm2 active surface area (5.0 × 5.0 cm) and can be operated up to 80°C and 6.0 A/cm2. Construction details and material selection for the designed test cell are given in this document. Furthermore, findings related to pressure distribution analyzed by utilizing a pressure-sensitive foil, the cell performance indicated by polarization curves, and the reproducibility of results are described. Experimental data indicate the applicability of the presented testing device for relevant PEMWE component testing and material analysis.
An Augmented Multiphase Rail Launcher With a Modular Design: Extended Setup and Muzzle Fed Operation
(2024)
Die Neuberechnung der Kühllast von Gebäuden im Bestand wird immer dann nötig, wenn sich größere Nutzungsänderungen ergeben. Dabei ist die Datenlagen zur Bausubstanz und dem Aufbau der Umschließungsflächen meist unzureichend für die Eingabe in die Berechnungsalgorithmen nach VDI 2078:2015-06. Der Artikel analysiert an einem denkmalgeschützten Verwaltungsgebäude die wichtigsten Einflussfaktoren auf die Kühllast. Dabei wir auch ein Vergleich zur lange gültigen Vorgängerrichtline von 1996 durchgeführt.
Besondere Herausforderung: Weiterbildung. BIM: Einbinden von kleinen und mittelgroßen TGA-Büros
(2019)
Die Digitale Transformation im Bauwesen heißt Building Information Modeling, kurz BIM. Damit die zahlreichen kleinen und mittelständischen Ingenieur- und Planungsbüros hier mithalten können, müssen passende Weiterbildungs- und Einführungskonzepte für BIM geschaffen werden. Der Artikel untersucht die Herausforderungen und Hemmnisse dafür in Deutschland.
BIM in Lehre und Praxis
(2019)
Carbon Nanofibers (CNF) are considered to be a promising catalyst support material due to their unique characteristics, excellent mechanical, electrical and structural properties, high surface area and nevertheless, good interaction with metallic catalyst particles. The possibility of preparing CNF decorated with platinum by an electrochemical method was tested, using a hexachloroplatinic bath solution. The experiments were carried out with the aid of a Potentiostat/Galvanostat Ivium Technologies Vertex, in a three – electrode cell. The aim of the present work was to determine the electrochemical surface area (ECSA) of the CNF-Pt catalysts in relation to the functionalization treatment of fibers, using an electrochemical method. ECSA for different functionalized CNF-Pt catalysts was determined by cyclic voltammetry in 0.5 M H2SO4 solution. The highest active surface of platinum was obtained for the samples with CNF functionalized by plasma treatment using 80 W for 1800 s. The obtained results correlate very well with the particles size and distribution of platinum, revealed by scanning electron microscopy (SEM) and the quantity of deposited platinum determined by thermo gravimetrical analysis (TGA) respectively. Cyclic voltammetry (CV) has been proven to be a suitable method for estimation of the ECSA of the electrocatalysts.
The present paper presents one- and two-step approaches for electrochemical Pt and Ir deposition on a porous Ti-substrate to obtain a bifunctional oxygen electrode. Surface pre-treatment of the fiber-based Ti-substrate with oxalic acid provides an alternative to plasma treatment for partially stripping TiO2 from the electrode surface and roughening the topography. Electrochemical catalyst deposition performed directly onto the pretreated Ti-substrates bypasses unnecessary preparation and processing of catalyst support structures. A single Pt constant potential deposition (CPD), directly followed by pulsed electrodeposition (PED), created nanosized noble agglomerates. Subsequently, Ir was deposited via PED onto the Pt sub-structure to obtain a successively deposited PtIr catalyst layer. For the co-deposition of PtIr, a binary PtIr-alloy electrolyte was used applying PED. Micrographically, areal micro- and nano-scaled Pt sub-structure were observed, supplemented by homogenously distributed, nanosized Ir agglomerates for the successive PtIr deposition. In contrast, the PtIr co-deposition led to spherical, nanosized PtIr agglomerates. The electrochemical ORR and OER activity showed increased hydrogen desorption peaks for the Pt-deposited substrate, as well as broadening and flattening of the hydrogen desorption peaks for PtIr deposited substrates. The anodic kinetic parameters for the prepared electrodes were found to be higher than those of a polished Ir-disc.
Building Information Modeling (BIM) wird im Bauwesen immer stärker gefordert. Der vorliegende Artikel befasst sich mit dem Datenaustausch für die TGA. Am Beispiel eines RLT-Gerätes werden der Detaillierungsgrad und der Datenaufbau mit IFC erläutert. Insbesondere zeigt sich hierbei, dass der Datenimport aufgrund fehlender Standards und Definitionen mit Datenverlust einhergeht. Damit ergibt sich ein Auftrag an die Softwareunternehmen hier für eindeutige Standards zu sorgen.
In the polymer electrolyte membrane fuel cells (PEMFC) state of the art, rare and expensive platinum group metals (PGM) or PGM alloys are used as catalyst material. Reduction of PGMs in PEMFC electrodes is strongly required to reach cost targets for this technology. An optimal catalyst utilization is achieved in case of nano-structured particles supported on carbon material with a large specific surface area. In this study, graphitic material, in form of carbon nanofibers (CNF), is decorated with Pt particles, serving as catalyst material for PEMFC electrodes with low Pt loading. As a novelty, the effect of oxygen plasma treatment of CNFs previously to platinum particle deposition has been studied. Electrodes are investigated in respect of the optimal morphology, microstructure as well as electrochemical properties. Therefore, samples are characterized by means of scanning electron microscopy combined with energy dispersive X-ray analysis, transmission electron microscopy, thermogravimetry, X-ray diffraction as well as X-ray fluorescence analysis. In order to determine the electrochemical active surface area of catalyst particles, cyclic voltammetry has been performed in 0.5 M sulphuric acid. Selected samples have been investigated in a PEMFC test bench according to their polarization behavior.
RLT-Geräte werden meist auf eine Lebensdauer von 15 Jahren ausgelegt. Die Erfahrung zeigt jedoch, dass viele Anlagen mehr oder weniger unverändert bis zu 25 Jahren betrieben werden. Damit müssen aktuell projektierte RLT-Anlagen auch bei dem erwarteten Klimawandel die gewünschten Zuluftparameter (Temperatur und Luftfeuchte) einhalten. Der Artikel untersjucht den einfluss des Klimawandels für Deutschland bezogen auf die Klimatisierung einer exemplarischen Krankenhausintensivstation.
Gebäude sind immer auch ein Ausdruck der Zeit, in der sie erbaut wurden. Oft bleiben sie sehr lange erhalten und erfahren über die Jahrzehnte mehrfache Nutzungsänderungen. Betroffen sind alte Produktionshallen ebenso wie Verwaltungsimmobilien. Die Gebäudehülle bleibt bei einer Umnutzung meist unangetastet. Aufgabe der Technischen Gebäudeausrüstung ist es dann, das Raumklima für die Nutzer unter den geänderten Bedingungen behaglich zu gestalten und die Aspekte der Energieeffizienz und Nachhaltigkeit nicht aus den Augen zu verlieren. Insbesondere die Kühlung der Gebäude im Sommer steht aufgrund der steigenden internen Lasten und der solaren Gewinne durch große Glasfassaden im Vordergrund.